Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1076
    Keywords: Key words Transcutaneous ; monitoring ; Carbon dioxide ; tension ; Oxygen tension ; Neonates ; Infants
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Whereas during the last few years handling of the transcutaneous PO2 (tcPO2) and PCO2 (tcPCO2) sensor has been simplified, the high electrode temperature and the short application time remain major drawbacks. In order to determine whether the application of a topical metabolic inhibitor allows reliable measurement at a sensor temperature of 42° C for a period of up to 12 h, we performed a prospective, open, nonrandomized study in a sequential sample of 20 critically ill neonates. A total of 120 comparisons (six repeated measurements per patient) between arterial and transcutaneous values were obtained. Transcutaneous values were measured with a control sensor at 44° C (conventional contact medium, average application time 3 h) and a test sensor at 42° C (Eugenol solution, average application time 8 h). Comparison of tcPO2 and PaO2 at 42° C (Eugenol solution) showed a mean difference of +0.16 kPa (range +1.60 to –2.00 kPa), limits of agreement +1.88 and –1.56 kPa. Comparison of tcPO2 and PaO2 at 44° C (control sensor) revealed a mean difference of +0.02 kPa (range +2.60 to –1.90 kPa), limits of agreement +2.12 and –2.08 kPa. Comparison of tcPCO2 and PaCO2 at 42° C (Eugenol solution) showed a mean difference of +0.91 (range +2.30 to +0.10 kPa), limits of agreement +2.24 and –0.42 kPa. Comparison of tcPCO2 and PaCO2 at 44° C (control sensor) revealed a mean difference of +0.63 kPa (range 1.50 to –0.30 kPa), limits of agreement +1.73 and –0.47 kPa. Conclusion Our results show that the use of an Eugenol solution allows reliable measurement of tcPO2 at a heating temperature of 42° C; the application time can be prolongued up to a maximum of 12 h without aggravating the skin lesions. The performance of the tcPCO2 monitor was slightly worse at 42° C than at 44° C suggesting that for the Eugenol solution the metabolic offset should be corrected.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...