    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Pacing and clinical electrophysiology 28 (2005), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: This is a report on a patient with an implanted cardioverter defibrillator (ICD) who intentionally underwent magnetic resonance imaging (MRI) of a malignant brain tumor. To avoid inadequate detection of ventricular tachycardia (VT) or ventricular fibrillation (VF), the ICD was inactivated by programming the VT-detection and VT/VF-therapy status off. The patient came through the protocol safely and without any difficulty or discomfort. There was no arrhythmic event. MRI affected neither programmed data nor the function of the ICD system.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: VAHLHAUS, C., et al.: Interference with Cardiac Pacemakers by Magnetic Resonance Imaging: Are There Irreversible Changes at 0.5 Tesla? The safety and feasibility of magnetic resonance imaging (MRI) in patients with cardiac pacemakers is an issue of gaining significance. The effect of MRI on patients' pacemaker systems has only been analyzed retrospectively in some case reports. Therefore, this study prospectively investigated if MRI causes irreversible changes in patients' pacemaker systems. The effect of MRI at 0.5 Tesla on sensing and stimulation thresholds, lead impedance and battery voltage, current, and impedance was estimated during 34 MRI examinations in 32 patients with implanted pacemakers. After measurements at baseline and with documentation of intrinsic rhythm and modification of the pacing mode, patients underwent MRI. The rest of the function time of the pacemaker was calculated. Measurements were again performed after 99.5 ± 29.6 minutes (mean ± SD), immediately after MRI examination, and 3 months later. Lead impedance and sensing and stimulation thresholds did not change after MRI. Battery voltage decreased immediately after MRI and recovered 3 months later. Battery current and impedance tended to increase. The calculated rest of function time did not change immediately after MRI. MRI affected neither pacemaker programmed data, nor the ability to interrogate, program, or use telemetry. Surprisingly, in the gantry of the scanner, temporary deactivation of the reed switch occurred in 12 of 32 patients when positioned in the center of the magnetic field. Missing activation of the reed switch through the static magnetic field at 0.5 Tesla is not unusual. MRI at 0.5 Tesla does not cause irreversible changes in patients' pacemaker systems.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5020 , USA and 9600 Garsington Road , Oxford OX4 2XG , England . : Blackwell Science Inc
    Journal of cardiac surgery 20 (2005), S. 0 
    ISSN: 1540-8191
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract  Background and Aim: Whether the CK-MB reducing effect of ischemic preconditioning (IP) by unstable angina within 24 to 48 hours before CABG is achieved by early or by delayed preconditioning of left ventricular myocardium in humans is unknown. We investigated whether IP is associated with phosphorylation of p38 MAPK (characteristic for early preconditioning) or with increased protein expression of HSP-72 (characteristic for delayed preconditioning) at the time of CABG in patients. Methods: Nineteen patients were grouped according to the occurrence of ischemic episodes within 48 hours before CABG. The patients without angina were assigned to the control group (CON, n = 10) whereas patients who had experienced angina within 48 hours before CABG were assigned to the preconditioned group (IP, n = 9). The effect of IP on the CABG induced maximal release of creatine kinase (CK) and CK-MB was examined. Left ventricular biopsy specimens taken immediately before cross clamping from ischemic (ISCH) and from reference (REF) areas were processed to analyze p38 MAPK phosphorylation and HSP-72-protein expression. Results: While IP significantly reduced CK-MB (18.7 ± 1.3 vs. 13.8 ± 1.5 U/L, mean ± SEM, p 〈 0.05), it only tended to reduce CK (292.7 ± 32.8 vs. 274.1±31.1 U/L, p = NS, mean ± SEM). CK-MB release for any given cross-clamp time was significantly reduced by IP (regression lines: CON, y= 0.4x+ 2, r= 0.8; IP, y= 0.1x+ 10, r= 0.2; p 〈 0.01, ANCOVA). There was no effect of IP on left ventricular p38 MAPK phosphorylation. IP increased left ventricular HSP-72-protein expression in ischemic areas when compared to reference areas (1.78 ± 0.35 vs. 2.58 ± 0.65, REF vs. ISCH, PhosphorImager units ×106, mean ± SEM, p 〈 0.05, ANCOVA). Conclusions: Thus, in the human left ventricular myocardium there is a second window of protection lasting for at least 48 hours, while at that time the early phase of preconditioning has already gone.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1542-474X
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Aim: This study investigated the value of epicardial mapping immediately before CABG in the differentiation of hibernating from scarred myocardium in correlation to the noninvasive gold standard 18F-FDG PET.Methods and Results: In 35 patients with CAD, myocardial perfusion (99mTc-Tetrofosmin-SPECT), viability (18F-FDG-PET), and function (LVangiography) were assessed before CABG. 102 bipolar epicardial electrograms per patient (n = 3570 electrograms) were recorded simultaneously with a ventricular jacket array. Based on the scintigraphic and LV angiographic data at the site of each electrode with good myocardial contact (n = 1963), segments (n = 492, 14.1 ± 5.6 per patient; mean ± SD) were classified into three groups: hibernating (n = 139), scarred (n = 104), and control (n = 249). Regional mean bipolar voltage values were calculated for Receiver Operating Characteristic (ROC) analysis. Mean bipolar voltage was significantly lower in scarred when compared to hibernating myocardium. ROC curve analysis (area under the curve of O.92 ± 0.47, mean ± SE) for mean bipolar voltage to discriminate between hibernating and scarred myocardium revealed a sensitivity of 94% with a specificity of 83% at a cut-off value of 8.75 mV.Conclusion: Hibernating myocardium can be differentiated correctly from scarred myocardium by direct epicardial mapping. In the future, hibernating myocardium may be detectable by body surface mapping techniques using inverse solutions. A.N.E. 2002;7(4):349–356
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1572-8595
    Keywords: implantable devices ; atrial fibrillation ; ventricular tachycardia ; safety ; efficacy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The high prevalence of atrial fibrillation (AF) and its clinical complications, the poor efficacy of medical therapy for preventing recurrences, and dissatisfaction with alternative modes of therapy stimulated interest in implantable atrial and combined atrioventricular defibrillators. In a multicenter study, the safety and efficacy of a stand alone implantable atrial defibrillator, the Metrix system, were evaluated. The device was implanted in 51 patients with highly symptomatic episodes of AF refractory to pharmacological treatment. During a follow-up of 9 months, 96% of 227 spontaneous AF episodes were successfully converted to sinus rhythm in 41 patients. In 62 episodes (27%), several shocks and/or additional drug treatment were required to maintain stable sinus rhythm because of early recurrences of AF. A total of 3719 shocks were delivered and no induction of ventricular proarrhythmia or inaccurately synchronized shocks occurred. The AF detection algorithm exhibited a 100% specificity for the recognition of sinus rhythm and a 92.3% sensitivity for the detection of AF. The combined atrioventricular defibrillator, Jewel AF 7250, was evaluated in a multicenter, randomized, cross-over trial. The primary study objectives included: overall safety as determined by complications-free survival at 6 months, efficacy of tiered atrial pacing and defibrillation therapies for termination of spontaneous atrial tachycardias (AT) and AF, and relative sensitivity of a new dual-chamber detection algorithm. The device was implanted in 211 patients with either a history of ventricular tachyarrhythmias (VT/VF) alone or with a history of both AT/AF and VT/VF. During a mean follow-up of 4.5 months, it has been shown that the Jewel AF is safe and effective in treating atrial and ventricular tachyarrhythmias. Pace termination of 85% of AT episodes were achieved with painless delivery of antitachycardia pacing; additional 35% of AT episodes were terminated by high frequency burst pacing. Conclusions: The stand alone implantable atrial defibrillator may be safe and clinically useful in selected patients for the treatment of highly symptomatic, drug resistant recurrences of AF. The combined atrioventricular defibrillator may be particularly indicated in patients presenting with both a history of atrial and ventricular tachyarrhythmias.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Journal of interventional cardiac electrophysiology 4 (2000), S. 121-125 
    ISSN: 1572-8595
    Keywords: atrial flutter ; catheter ablation ; success rate ; long-term follow-up ; recurrence
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Radiofrequency catheter ablation of typical atrial flutter at the isthmus between the tricuspid annulus and the inferior vena cava is established. However in selected patients, the creation of a continuous linear lesion at the targeted isthmus requires a lengthened procedure or is not feasible at all and atrial flutter recurrences are common. In a retrospective analysis, we found that an intraoperatively determined distance between the tricuspid annulus and the inferior vena cava of 〈.2.5 cm is an independent predictor of a lengthened or failed ablation procedure. Additional equipment, e.g., long introducer sheaths, adapted ablation catheter design, or irrigated tip ablation, as well as alternative ablation approaches, e.g., linear lesions between the tricuspid annulus and Eustachian ridge, have been invented in order to increase the acute success rate or decrease fluoroscopy and procedure time. In a prospective study on the effects of various conduction properties at the isthmus between tricuspid annulus and inferior vena cava following radiofrequency ablation of atrial flutter, we showed previously that others than a complete bidirectional conduction block predicts a high recurrence rate of atrial flutter. For determination of transisthmal conduction properties following ablation, established mapping approaches are documentation of double potentials at the ablation line and right atrial activation sequence following posteroseptal and low lateral right atrial pacing. Novel threedimensional mapping systems, i.e., Carto® and EnSite®, may further enhance the accuracy of conventional mapping techniques.
    Type of Medium: Electronic Resource