Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Pacing and clinical electrophysiology 23 (2000), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We report our experience of pacemaker treatment in a premature infant of 830 g with congenital complete atrioventricular block due to maternal Sjogren's Syndrome. The infant was delivered by cesarean section at an estimated gestational age of 26 weeks because of fetal bradycardia, decreasing fetal movements, and hydrops. Immediate postnatal transesophageal ventricular pacing was not successful, whereas transthoracic pacing with self-adhesive patch electrodes adapted to body size resulted in an effective increase of the infant's heart rate until operative application of temporary epimyocardial pacing wires allowed external stimulation of the heart.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1076
    Keywords: Polycythaemia Neonate ; Exchange transfusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We tested whether crystalliod solutions could be used instead of colloid solutions for partial exchange transfusions (PET) in polycythaemic neonates because crystalloid solutions are cheap, carry no risk of anaphylactic reactions and can be sterilized. We randomly assigned 20 term neonates with venous haematocrit (Hct)〉0.65 l/l to PET with either a serum preparation (BISEKO) or Ringer solution. Plasma volume (PV) was measured with Evans blue dilution. Blood volume (BV) and red cell mass were calculated from PV and venous Hct. Before PET both serum and Ringer groups had the same Hct (0.69 (0.66–0.76) vs 0.69 (0.66–0.71) l/l; median (range)) and BV (108 (81–116) versus 96 (68–121) ml/kg. During PET an equivalent amount of blood was withdrawn stepwise (19 (14–26) versus 17 (13–25) ml/kg and replaced by either serum or Ringer solution. More of the Ringer solution (median 77%) than of the serum (median 36%) given left the intravascular space within 4 h after PET (P=0.016); but there was no signficant difference in Hct after Ringer-PET compared to serum-PET (median 0.58 vs 0.56 l/l). No infant required repeat PET. Ringer-PET reduced BV from high to normal values (from median 96 to 83 ml/kg;P=0.005), whereas after serum-PET BV remained high (from median 108 to 98 ml/kg; not significant). Conclusion PET with Ringer solution resulted in a haemodilution comparable to PET with serum and a correction of hypervolaemia.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...