Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International urogynecology journal 5 (1994), S. 191-191 
    ISSN: 1433-3023
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 22 (1994), S. 202-211 
    ISSN: 1573-9686
    Keywords: Neuroprosthetics ; Electrode corrosion ; 316LVM stainless steel ; MP35N nickel-cobalt alloy ; Electrical transients
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract Functional neuromuscular stimulation (FNS) is often limited by electrode malfunctions such as corrosion and breakage, particularly for intramuscular and epimysial type electrodes. As a result, the electrochemical charge injection characteristics and corrosion responses of single strand 316LVM stainless steel and MP35N nickel-cobalt alloy electrodes were evaluatedin vitro. For charge balance, capacitor coupled monophasic protocols with varying charge injections were employed. Electrodes were evaluated with either positive-first or negative-first pulses, 60 Hz, 100 μsec pulse duration, and stimulation periods from 100 to 240 hours. Charge injection densities ranged from 20 to 80 μC/cm2. For both anodic-first and cathodic-first pulsing, the potential transients for the MP35N electrodes were more extreme than for the 316LVM electrodes over the test period, and increased corrosion was apparent on the MP35N electrodes from both optical and scanning electron microscopy. Therefore, 316LVM, but not MP35N, may be suitable for FNS applications with charge injection densities less than 40 μC/cm2.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 28 (1994), S. 233-240 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An In vitro comparison of the corrosion response of 316LVM stainless steel and MP35N (a CoNiCrMo alloy) electrodes under conditions appropriate to applications in functional electrical stimulation (FES) was made. Electrodes of both alloys were subjected to a cathodic 40 μC/cm2 charge injection protocol and the potential transient response was recorded over a 96 h period. The transient responses were compared with potentiodynamic polarization data used to establish the quasiequilibrium response of the alloys in the carbonate and phosphate-buffered saline electrolyte used in the study. The MP35N electrodes exhibited extensive pitting corrosion during charge injection, whereas little corrosion was observed on 316LVM electrodes. An explanation for the susceptibility of MP35N to corrosion during charge injection is found in the potentiodynamic polarization data, which reveal a breakdown potential (critical pitting potential) of 0.45 V (SCE) for MP35N compared with 1.05 V (SCE) for 316LVM. Factors that may influence corrosion response during charge injection from alloys exhibiting active-passive behavior are discussed. © 1994 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...