Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 635 (1991), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Physiology 56 (1994), S. 691-709 
    ISSN: 0066-4278
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Medicine , Biology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 220 (1968), S. 777-778 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Copper films of 99-995 per cent purity were prepared by evaporation onto glass substrates coated with collodion. Deposition was carried out at a rate of approximately 65 A s-1 under a residual pressure of 2 x 10~6 torr. The substrates were suitably masked so that each yielded twelve circular films ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1573-9686
    Keywords: Dental implants ; Biomechanics ; Biomaterials ; Finite element analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract Dental implants have been used and studied for the replacement of missing teeth for many years. Finite element stress analysis (FESA) has previously been used in their evaluation to study the effect of various design parameters on induced stresses. A twodimensional FESA was used to evaluate the effect that the implant-bone interface elastic modulus has on the stress distribution around LTI carbon and aluminum oxide dental implants. The results of this investigation indicate that a soft tissue interface between implants and bone negates the effect of implant elastic modulus and results in stress profiles that were almost identical for the LTI carbon and aluminum oxide implants.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 14 (1980), S. 23-29 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Three-dimensional finite element analysis (FEA) has been used to determine the implant-bone interface characteristics of bioglass dental implants. The results of the FEA were verified by comparison with the results of mechanical testing performed on animal implant specimens. The results of the study showed that the assumption of a discontinuous change of elastic properties at the bone-implant interface was a poor assumption for the bioglass implants. Interface elastic moduli of 354.0, 155.0, and 47.0 MPa for conditions of 25, 50, and 100% tissue attachment were determined for the bioglass implants.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 875-885 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Three-dimensional finite element stress analysis was used to study the effects that implant neck geometry and the tissue properties at the implant-bone interface have on the stress distribution around freestanding blade- and post-type LTI carbon and aluminum oxide dental implants. Implants having neck flares of 13° and 26° were studied. In addition, to simulate fibrous encapsulation of the implant as opposed to a direct bone apposition retention mechanism, a soft tissue interposing layer between implant and bone was also modeled. The results of the study indicate that a reduction in neck flare from 26° to 13° was a positive design change for blade- and post-type LTI carbon implants and blade-type aluminum oxide implant but not for post-type aluminum oxide implant. The results of the study indicate the presence of fibrous tissue surrounding the implants may be indicative of a failing system and may be the result of either hypophysiological stress (aluminum oxide implants) or hyperphysiological stress (LTI carbon implants).
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 887-899 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The clinical performance of LTI carbon, carbon-coated aluminum oxide, and uncoated aluminum oxide blade-type dental implants was studied in baboons. The objective of the study was to determine the effect that implant material elastic modulus and surface composition have on implant performance. Clinical parameters of mobility, sulcus depth, soft tissue characteristics, and radiographic appearance were used in the evaluation. The implants were placed in healed extraction sites in adult female baboons and were used as a distal abutment for a three-unit fixed gold prosthesis. The restorations were allowed to assume normal occlusal function and were left in situ for a period of two years. The radiographic and sulcus depth measurements appeared inferior for the LTI carbon implants and best for the carbon-coated aluminum oxide implants. No differences in mobility or soft tissue characteristics were noted for the three implant systems. Two implants both in the same animal - one LTI carbon and one uncoated aluminum oxide - were definite clinical failures. The results of the study indicate that an elastic modulus mismatch between implant and bone is not an a priori cause of implant failure and that the implant surface composition had little apparent effect on the clinical and radiographic performance of these implant materials.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 15 (1981), S. 879-887 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A three-dimensional finite element analysis (FEA) has been used to determine the effect of implant elastic modulus on stresses in tissues around LTI carbon and aluminium oxide dental implants. The finite element model was constructed to represent a baboon mandible containing a blade type dental implant. A three unit fixed bridge was modeled connecting the dental implant to a natural molar. The results of the study indicate that stress levels of approximately a factor of 3 lower in the crestal region can be expected for aluminum oxide implants when compared to the LTI carbon implants. It was also observed that the use of LTI carbon and aluminium oxide dental implants as an abutment in a fixed bridge results in a reduction of stresses in tissues around the natural tooth when compared to normal physiological stress levels.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 10 (1976), S. 311-323 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The purpose of this investigation was to study bone growth into porous polyethylene rods as a function of time and pore structure. Previous studies have indicated the biocompatibility of solid polyethylene materials which are currently being used clinically. Porous polyethylene rods were implanted in the femurs of mongrel dogs which were sacrificed four, eight, and 16 weeks postoperatively. The implants were then sectioned and examined histologically and microradiographically. Quantitative techniques were employed to determine the amount of bone ingrowth as a function of time and pore size. The pore structures of the materials were evaluated using optical microscopy and mercury intrusion porosimetry.The results of this investigation have demonstrated that porous polyethylene is capable of accepting bone growth into pores as small as 40 μm. The optimum rate of bone ingrowth was observed in pore sizes of approximately 100 to 135 μm, with no increase in the rate of bone ingrowth observed in samples possessing larger pore sizes. No adverse tissue response was found at implant times up to 16 weeks in pore sizes of 100 μm or larger.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A study was undertaken to evaluate the ion-beam texturing of aluminum oxide as a means of providing a surface which will produce a biological prosthetic attachment. A wafflelike pattern of surface contours 150 × 75 × 35 μm deep was produced on cylindrical dental implants. The textured surfaces were compared to the as received surfaces in adult mongrel dogs. Implants were inserted into surgically modified healed extraction sites and were left in place for six months. Post-sacrifice mechanical testing was used to quantify the displacement response of the implants.The clinical, radiographic and mechanical testing evaluations did not reveal any statistically significant differences in the performance of the dental implants. However, it was observed that anatomical site and mandibular geometry with respect to implant size play a significant role in affecting implant retention.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗