Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 223-230 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Heterocyclic amines ; Chicken legs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Several extraction, separation and detection methods for heterocyclic amines (HAs) in chicken legs were evaluated by liquid chromatography. Results showed that the most appropriate extraction method includes the removal of macrosubstances by centrifugation and subsequent purification using a PRS (propylsulfonic acid silica gel) and a C18 cartridge, and the recovery obtained ranged between 51 and 89 %. For HPLC separation, a binary solvent system consisting of acetonitrile and 0.05 M ammonium acetate solution (pH 3.6) with gradient elution with flow rate of 1.0 mL min−1 and detection at 258 nm was used to resolve 16 HAs. With fluorescence nine HAs could be detected by employing a programmable wavelength, and the sensitivity was 100–400 times higher than that by UV detection. The detection limits for UV and fluorescence detection were 0.02≈0.5 ng and 0.05≈3 pg respectively, with a signal-to-noise ratio 3. The presence of HAs in fried chicken legs was also determined.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 28 (1994), S. 881-890 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In vivo and electron microscopy were used to study the hepatocellular responses of rat livers to intravenously injected polymeric microspheres. Two microsphere preparation with different surface characteristics and degradability were used in this study. In vivo microscopy revealed that both poly(benzyl L-glutamate) (PBLG) and poly(hydroxypropyl L-glutamine) (PHPG) microspheres caused disturbance in the microcirculation of rat liver up to 2 months after injection. The observed changes included stagnant flow and adherence of white blood cells to the endothelial lining of venules and sinusoids. Kupffer cell (KC) activation following phagocytosis of microspheres was evidenced by the enlargement of KCs and increased number of KCs taking up fluorescent latex particles. Electron microscopy of rat livers revealed a wide range of hepatocellular injury associated with the administration of PBLG and PHPG microspheres. These results indicate that a small amount of remaining microspheres is sufficient to induce continuous disturbance to hepatic microcirculation and that particulate drug carriers should be designed to be rapidly degraded so that the return to normal liver function is possible. © 1994 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...