Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Archives of toxicology 65 (1991), S. 52-58 
    ISSN: 1432-0738
    Keywords: p-Chloronitrobenzene ; Urinary metabolites ; Rat ; Gas chromatography-mass spectrometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Urinary metabolites in rats treated withp-chloronitrobenzene were identified by gas chromatography-mass spectrometry. A single dose of 100 mg/kg body wtp-chloronitrobenzene was administered intraperitoneally to male Sprague-Dawley rats and urine samples were collected from the 8th to 24th hour after the administration. Urinary metabolites were extracted with diethylether at pH 1.0 and pH 10.0 from urine samples hydrolyzed with acid and base and from intact urine samples. Aliquots of the ethereal extracts were injected into a gas chromatograph-mass spectrometer. Nine substances were identified:p-chloroaniline, 2,4-dichloroaniline,p-nitrothiophenol, 2-chloro-5-nitrophenol, 2-amino-5-chlorophenol,p-chloroformanilide, 4-chloro-2-hydroxyacetanilide, a small amount ofp-chloroacetanilide and traces of unchangedp-chloronitrobenzene.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1246
    Keywords: Lead exposure ; Urinary excretion ; δ-Aminolevulinic acid ; Coproporphyrin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Fluorometric methods for determining δ-aminolevulinic acid (ALA) and coproporphyrin (CP) in urine have been recently developed by using high-performance liquid chromatography (HPLC). In the present study, urinary ALA and CP in lead-exposed workers were determined with these fluorometric HPLC methods and the conventional methods, and the results obtained were compared. In lead workers with a urinary ALA ≥ 5 mg/l, the values obtained with the fluorometric HPLC method corresponded well with those measured with the conventional colorimetric method. In contrast, in lead workers with ALA 〈 5 mg/l, ALA values obtained with the fluorometric HPLC method were lower than those measured with the conventional method, suggesting the possibility of matrix interference in urine. The urinary CP values obtained with the conventional method of Rimington (1971) were higher than those measured with the fluorometric HPLC method, though the correlation was good.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 68 (1996), S. 58-63 
    ISSN: 1432-1246
    Keywords: Lead in Plasma ; Lead exposure indicators ; Workers ; Heme synthesis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In order to clarify the bioavailability of lead in plasma (PbP), we performed a study on five workers in a Japanese factory manufacturing lead glass-based paints. Blood and urine samples were obtained over a period of 15 months, during which time the workers took it in turns to perform sifting work (with the highest level of lead exposure) for 1-month periods. A total of 75 sets of blood and urine samples were thus obtained. We determined whole blood lead (PbB), PbP, Urinary coproporphyrin (CPU), urinary δ-aminolevulinic acid (ALAU), urinary lead (PbU) and ALA in plasma (ALAP). In the 15 sets of samples obtained at the end of the period with a high level of lead exposure, PbP correlated significantly with ALAU, CPU, PbU and ALAP, but PbB correlated significantly only with PbU. In the 60 sets of samples obtained following a low level of lead exposure, correlation coefficients between the concentrations of PbP and of ALAU, CPU and PbU exceeded those between the concentrations of PbB and of ALAU, CPU and PbU. These findings indicate that PbP is a better dose indicator of lead biochemically available for heme synthesis and that PbU has a closer correlation with PbP than with PbB.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1246
    Keywords: Lead ; Delta-aminolevulinic acid ; HPLC ; Biological monitoring
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A new sensitive HPLC method for the determination of urinary delta-aminolevulinic acid (ALA-U) was used to evaluate the relationship between blood-lead (Pb-B) and ALA-U levels in male workers exposed to lead. The differences between the ALA-U levels determined by this method (ALAU-HP) and by a colorimetric method (ALA-U-CL) are discussed. The HPLC method gave values similar to the ALA-U-CL values at high ALA-U level. However, at low blood-lead levels (58 ± 22 μg/l, n = 23), the mean ALA-U-HP level corrected by urinary creatinine level was one-third of the corrected ALA-UCL level (0.83 ± 0.14 and 2.4 ± 0.5 mg/g creatinine, respectively). A significant increase of the mean corrected ALA-U-HP level was observed at 162 ± 22 μg/l Pb-B (P 〈 0.05, n = 26), while that of ALA-UCL was observed at 245 ± 30 μg/l Pb-B (P 〈 0.01, n = 37). The regression equation based on the logistic model fitted well to the relationship data between the Pb-B level and the percentage of the subjects with corrected ALA-U-HP above the cut-off point (1.12 mg/g creatinine) and the expected Pb-B level for 50% response was 270 μg/l Pb-B, while it did not fit well to the relationship data between Pb-B level and the percentage of the subjects with corrected ALAU-CL above the cut-off point (3.5 mg/g creatinine). The maximum responses for the two sets of corrected ALA-U levels were both observed at 625 ± 25 μg/l. The corrected ALA-U level by HPLC method seems to be a useful indicator for biological monitoring of exposure to lead at low levels (〈 400 μg/l Pb-B = health-based biological limit, WHO) as well as high ones.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 61 (1989), S. 426-426 
    ISSN: 1432-1246
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...