Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electroanalysis 9 (1997), S. 541-543 
    ISSN: 1040-0397
    Keywords: Amperometric detection ; Solid-phase extraction ; Flow injection analysis ; Nickel electrode ; Ethanol ; Wine analysis ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Ethanol in wines was determined by flow injection analysis with an amperometric detector using an oxidized nickel wire. Solid-phase extraction with a strong anion exchanger was used to remove interferences such as organic acids from the matrix, and the residue of the extraction was injected directly into the FIA system. The recoveries of ethanol from wines spiked with standards ranged from 101% to 103%. The response of the nickel electrode to ethanol is dependent on the applied potential and the pH of the carrier. The optimal conditions for the detection of ethanol were an applied potential of +0.60 V (vs. Ag/AgCl) in a carrier of 100 mM sodium hydroxide solution. The electrode exhibited a linear response from 10-5 to 10-3 M, with a detection limit of 1 × 10-6 M. The method was demonstrated by the determination of ethanol in wines.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electroanalysis 9 (1997), S. 544-548 
    ISSN: 1040-0397
    Keywords: Ethanol oxidation ; Cyclic voltammetry ; Osteryoung square-wave voltammetry ; Internal standard ; Wine analysis ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A rapid method for the electroanalysis of ethanol is presented that incorporates flow extraction at room temperature, with voltammetric detection and potassium ferrocyanide [K4Fe(CN)6] as internal standard. In 0.1 M NaOH electrolyte, ethanol was oxidised at a platinum comb-shaped working electrode at -300 mV (vs. a Ag/AgCl reference electrode) and K4Fe(CN)6 was oxidized at +180 mV. The ratio of the anodic peak currents was linear with ethanol concentration in the range of 0.1 to 8.0% (v./v.), and the detection limit (calculated as 3 σ background) was 0.012 % (v./v.) for Osteryoung square wave voltammetry (OSWV) and 0.023 %(v./v.) for cyclic voltammetry (CV). The average extraction efficiency of ethanol from aqueous solutions, at 20 ± 1°C, was 8.5%. The repeatability was in the range of 2.5 to 3.3% RSD (n = 8), and accuracy was in the range of 95.2 to 104.7% for the determination of wine samples. Application to wines compared well with GC and HPLC methods and the nominal ethanol concentration determined by gravimetry. Analytical parameters in CV and OSWV are optimized, and the dependence of the extraction efficiency with temperature and nitrogen gas flow is presented.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...