Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 72 (1998), S. 2421-2423 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The piezoelectric and dielectric constants in different crystal orientations of the lead zirconate titanate (PZT) have been phenomenologically calculated for the compositions near the morphotropic phase boundary at room temperature. For a tetragonal PZT, the effective piezoelectric constant d33 monotonously decreases as the crystal cutting angle from the spontaneous polarization direction [001] increases. However, for a rhombohedral PZT, the effective piezoelectric constant d33[001]// along the perovskite [001] direction was found to be much larger than those along the spontaneous polarization direction [111]. This crystal orientation-related enhancement is emphasized as the composition approaches the morphotropic phase boundary. This suggests that by adopting the perovskite [001] orientation with a rhombohedral composition near the morphotropic phase boundary, the piezoelectric constant d33 for PZT can be greatly enhanced. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-8663
    Keywords: high power ; piezoelectric ; resonance/antiresonance ; pulse drive method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Three techniques for measuring high voltage/power piezoelectric properties, which have been developed recently, are compared: a voltage-constant piezoelectric resonance method, a current-constant piezoelectric resonance method, and a pulse drive method. The conventional resonance method with a constant voltage circuit exhibits significant distortion (or a hysteresis) in the resonance frequency spectrum under a high vibration level due to large elastic non-linearity, which limits precise determination of the electromechanical coupling parameters. To the contrary, the resonance method with a constant current circuit (i.e., constant velocity) can determine the coupling parameters more precisely from a perfectly-symmetrical resonance spectrum. The general problem in both resonance methods is heat generation in the sample during the measurement. In order to separate the temperature characteristic from the non-linearity, it is recommended that the pulse method be used in parallel, even though the accuracy is not very high.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...