Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Osteoporosis international 9 (1999), S. S24 
    ISSN: 1433-2965
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-2965
    Keywords: Key words:Bone mineral density – Metacarpal morphometry – Osteoporosis – Semi-automated – Vertebral fracture
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract: Metacarpal morphometry represents a potentially cheap and widely available non-invasive assessment of skeletal status. In two cross-sectional studies, we compared the performance characteristics of a semi-automated technique (the Teijin Bonalyzer) with an in-house manual measurement, and with measures of skeletal strength at other sites. The metacarpal cortical index (mCI) was measured on hand radiographs of 178 osteoporotic women using both the Teijin Bonalyzer and a digitizing tablet. Measurements on the latter were consistently lower than with the Bonalyzer except for mCI (0.443 ± 0.080 vs 0.364 ± 0.060, p〈0.001), although correlation coefficients between these two methods were highly significant (r= 0.62–0.83, p〈0.001). The reproducibility errors of metacarpal bone mineral density (mBMD) were constant (1.1–1.2%) whilst those for mCI showed a marked operator-dependency (2.0–7.9%). In 379 elderly community-dwelling women, Bonalyzer mCI and mBMD showed a significant decline with age (r=−0.30 and −0.27 respectively, p〈0.05). Both mCI and mBMD correlated significantly with forearm BMD (r= 0.50 and 0.57 respectively, p〈0.001) and hip BMD (r= 0.48 and 0.53 respectively, p〈0.001). After adjustment for age and weight, hip BMD demonstrated the best discrimination for prevalent vertebral fractures as judged by the gradient of risk for a 1 SD decrease in measurement (odds ratio (OR) 2.17, 95% CI 1.56–3.01). Similar but smaller gradients of risk were shown by Bonalyzer mCI (OR 1.32, 95% CI 1.00–1.75), mBMD (OR 1.35, 95% CI 1.02–1.78) and forearm BMD (OR 1.39, 95% CI 1.08–1.80). MCI, and in particular mBMD, may be useful assessments of bone mass and fracture risk. In our study, it is comparable to peripheral assessment of skeletal status by forearm densitometry.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...