Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 156-157 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; trichlorophenols ; ammonia ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Microcolumn Separations 6 (1994), S. 369-372 
    ISSN: 1040-7685
    Keywords: capillary GC ; NPD ; aliphatic amines ; nitro and phosphorus compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The effect of ammonia as a carrier gas and as a make-up gas on the response of the nitrogen phosphorus detector (NPD) was investigated. This study showed that the response of the NPD increased 2.2 to 10.3 fold for all studied aliphatic amines when 5% ammonia in nitrogen was used as a make-up gas. This increase was about 5.3 to 22.8 fold when ammonia was used as a carrier gas. The response of the NPD for nitro-aromatic compounds increased 1.8 to 3.1 fold using 5% ammonia as a make-up gas and 4.2 fold when ammonia was used as a carrier gas. The higher response obtained using ammonia as the carrier gas is related to improvements in the chromatographic performance (reduced tailing). The response of the NPD to phosphorus compounds was about 1.5 times higher using ammonia either as a carrier gas or as a make-up gas compared to nitrogen. Although the noise of the NPD increased, the signal-to-noise ratios for both amines and phosphorus compounds improved with the use of ammonia.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Microcolumn Separations 5 (1993), S. 537-542 
    ISSN: 1040-7685
    Keywords: capillary GC ; ammonia ; helium ; amines ; chlorophenols ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A mixture of ammonia and helium was used as a carrier gas for capillary gas chromatographic analysis of aliphatic amines and dichlorophenols. The peak symmetry for aliphatic amines was drastically improved when the percentage of ammonia was 5-30%. The symmetry continued to improve, although less drastically, between 30-100%ammonia. The capacity factors of the amines decreased with increasing ammonia content up to 100%. 2,5-Dichlorophenol and 2,6-dichlorophenol could not be resolved when helium alone was used as the mobile phase with a column of intermediate polarity (cyanopropylmethylphenylsilicone). Complete separation was, however, achieved by increasing the ammonia content in the carrier gas to 50%. The ratio of the capacity factors (k'NH3/k'He) for the dichlorophenols increased linearly with increasing ammonia percentage up to 100% on the methylsilicone and cyanopropylmethylphenylsilicone columns.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 284-287 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Ammonia as carrier gas ; Chlorophenols ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 13 (1990), S. 252-256 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Ammonia ; Aliphatic amines ; Aromatic amines ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The use of ammonia as a carrier gas for the chromatography of aliphatic and aromatic amines has been investigated. As compared to nitrogen, ammonia gave drastically improved peak symmetry and lower capacity factors (k′) for primary and secondary amines on polar (Polyethylene glycol) and medium Polar (methylphenylcyanopropylsilicone) stationary Phases. The effect of ammonia was more Pronounced at low column temperatures. Considerably better detection limits of primary and secondary amines were obtained with ammonia as carrier gas than with nitrogen. No detrimental effects of using ammonia were observed on the gas chromatograph or on the columns over a period of about one year.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 17 (1994), S. 723-726 
    ISSN: 0935-6304
    Keywords: Carrier gas ; Ammonia ; Helium ; Hydrocarbons ; Amines ; Ketones ; Alcohols ; Phenols ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The effect of using ammonia as a carrier gas on the response of the flame ionization detector (FID) has been investigated. It was found that the FID response, calculated as the effective carbon number (ECN), increased for all the compounds studied when ammonia, rather than helium, was used. The change was 0-0. 9 carbon atom for hydrocarbons, one carbon atom for alcohols and diphenyl ether, and 0.4-1 carbon atom for phenols and ketones. The increase in ECN was larger for amines (0. 8-5 carbon atoms), but these numbers also reflected an improvement in chromatographic performance as a result of reduced adsorption on the column. The largest change in signal-to-noise ratio, a six-fold increase, was obtained for octyl-amine; ratios for hexyl methyl ketone, diisobutyl ketone, dihexyl-amine, dibutylamine, and N-methyloctylamine increased by a factor of 2-3 when ammonia was used as carrier gas. To determine the extent to which the effect on detector response was solely attributable to ammonia, a mixture of 5 % ammonia in nitrogen was used as detector make-up gas with helium as carrier gas. Under these conditions the noise in the FID increased but for most of the compounds studied the signal-to-noise ratio also increased.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 18 (1995), S. 757-759 
    ISSN: 0935-6304
    Keywords: CGC, ECD ; Ammonia, nitrogen ; Chlorophenols, nitro-aromatic compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The effect of ammonia on the electron capture detector (ECD) response has been investigated. Nitrogen with different ammonia concentrations (5-20%) was used as make-up gas. Compared to pure nitrogen, the ECD response decreased when the ammonia concentration in the make-up gas was 5%. However, the response increased when the ammonia concentration was 20%. The response factor of 4-chlorophenol increased 4 fold when ammonia was 20%. Also, di- and tri-chlorophenols increased by 30-50%. The nitroaromatic compounds responses increased by about 2-3.7 times with 20% ammonia in the make-up gas. The signal-to-noise (S/N) increased when 20% ammonia in nitrogen was used as make-up gas compared to pure nitrogen. Also, the detector linearity increased by 50% with ammonia.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...