Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Inorganic chemistry 1 (1962), S. 359-363 
    ISSN: 1520-510X
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Meteorology and atmospheric physics 60 (1996), S. 3-17 
    ISSN: 1436-5065
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geography , Physics
    Notes: Summary We compare radiosonde observations of relative humidity with NWP versions of the Meteorological Office Unified Model, and attempt to understand the causes of the systematic differences seen. The differences are found to have a different structure in cyclonic and anticyclonic situations over the UK. In cyclonic situations the mid-tropospheric temperature and humidity differences could be due to model biases, consistent with the conservation of energy; the latent heating from precipitation of the model's excess moisture would remove the model's cold bias. There is also some evidence for observational bias. Wetting of the sonde sensor in cloud can cause a moist bias at higher levels. The Väisala RS80 sonde also appears to have a dry bias near saturation. The Unified Model has a parameterisation for stratiform cloud which calculates the fractional cloud cover in a gridbox from the box-average relative humidity, allowing for sub-grid-scale variability within the box. This scheme has been tuned to give reasonable cloud amounts with the model's relative humidities. The cloud amounts implied (by the scheme) for radiosonde relative humidities are systematically less than the observed cloud. So assimilation of the observed humidities can significantly degrade analyses and predictions of cloud. Bias corrections for the radiosonde humidities have been calculated to compensate for this. Experiments have been performed to test the effect of the bias correction on the assimilation and prediction of cloud and precipation. With the control system, cloud cover and precipitation spins-up during the forecast period; the bias correction improves this. A large improvement was also found when the relationship between the temperature and humidity assimilation was changed; it is better to assume that temperature and relative humidity errors are uncorrelated, rather than temperature and specific humidity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Archives of orthopaedic and trauma surgery 106 (1987), S. 94-101 
    ISSN: 1434-3916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Twelve surface replacement arthroplasties were performed on the hips of ten mongrel dogs using scaled-down replicas of the Wagner prosthesis. The contralateral hips and two further animals served as nonoperated controls. Animals were killed 5 months postoperatively. Clinical, radiological, histological and fluorochrome-labelling studies were employed to assess the bony and soft tissue reaction to resurfacing arthroplasty. There was no clinical or radiographic evidence of prosthetic loosening. Histological examination disclosed a thick foreign body and chronic inflammatory membrane containing acrylic cement and polyethylene wear particles at the bone-cement interface of both components. Generally, the bone marrow and trabecula were viable. There was evidence of increased bony remodelling and new bone formation in the subchondral area. The similarity between the above findings and those of aseptic component loosening in man suggests a mechanism whereby wear debris initiate a biological foreign body reaction culminating in component loosening.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-2161
    Keywords: Key words Osteochondroma ; Complications ; MR imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Objective. To demonstrate the value of MR imaging in the diagnosis and differentiation of the various symptomatic complications of osteochondromas, providing pathological correlation with emphasis on the usefulness of MR imaging as a single imaging modality in these patients. Design. We retrospectively reviewed all MR examinations of clinically symptomatic osteochondromas (30 patients) performed at our institution between March 1990 and October 1997. Patients. Thirty patients had clinically symptomatic osteochondromas during the study period. Twenty patients were male and 10 were female. There were five cases of multiple osteochondromatosis. Pathological correlation was available in 24 patients. Results and conclusion . Symptomatic complications included fracture (7%), osseous deformity limiting range of motion (23%), vascular injury (7%), neurological compromise (10%), bursa formation (27%) and malignant transformation (27%). MR imaging was able to diagnose or suggest the etiology for the clinical symptomatology in all cases, demonstrating that it is an ideal imaging modality in the diagnostic evaluation of symptomatic complications of osteochondromas and often avoids the need for further imaging.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Skeletal radiology 10 (1983), S. 201-204 
    ISSN: 1432-2161
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1573-2649
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Patients undergoing limb salvage surgery for bone and soft tissue sarcoma of the extremities experience significant physical disability as a result of life-preserving treatment. The existing health status measures do not adequately evaluate physical function from the patient's perspective. This paper presents the developmental studies item selection, of a new measure, The Toronto Extremity Salvage Score (TESS). Patients with bone and soft tissue sarcoma (76 upper and 83 lower extremity) were randomly selected and mailed the TESS. Patients rated the severity and importance of physical disabilities; the response options included a ‘not applicable’; category and open-ended questions that allowed patients to suggest additional items for inclusion in the questionnaire. Therefore, patient perceptions were used to determine item content. Difficulty and importance frequencies were calculated and items rated “totally unimportant’ or ‘not applicable’ by 30% of the sample were eliminated. Extra items identified 30% of the time were added to the questionnaire. Internal consistency was evaluated by Cronbach's alpha. Test-retest reliability and validity were evaluated on subsequent patient samples. The intraclass correlation coefficient (ICC) was calculated for test-retest reliability and correlations with The Musculoskeletal Tumour Society Rating Scale (MSTS) were calculated for construct validity. Standardized effect sizes were calculated as a measure of responsiveness. Fifty upper extremity and sixty-six lower extremity patients responded to the mailed questionnaire. No items were eliminated based on importance or not applicable ratings. Sporting activities were identified as additional items in both the upper and lower extremity questionnaire. High internal consistency was demonstrated: 0.94 for the lower and 0.92 for the upper extremity questionnaires respectively. Test-retest reliability was evaluated at multiple time-points and the intraclass correlation coefficient was greater than 0.87 in all instances. Construct validity was shown by a moderate correlation with the MSTS. The effect sizes were large demonstrating responsiveness. The use of patients' perceptions in determining the content of the TESS has resulted in a reliable and valid measure that is able to detect change over time.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0736-0266
    Keywords: Flow cytometry ; Viability ; Cryopreservation ; Cartilage ; Osteosarcoma ; Chemotherapy ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Accurate estimation of cellular viability is important both in research and in aspects of orthopaedic clinical practice. We have been interested in the potential for flow cytometric application of fluorescein diacetate (FDA) in evaluating chondrocyte survival following cryopreservation of osteochondral allografts as well as in the assessment of sarcoma necrosis following preoperative chemotherapy. In order to evaluate the suitability of this method for cell viability assays, this study compared FDA with more traditional methodology (trypan blue, clonigenic assay, metabolic activity analysis, measurement of DNA synthesis, and histological assessment of necrosis). Both chondrocytes and sarcoma cells were exposed to various experimental injuries prior to viability analysis. Although it is evident from these experiments that FDA accurately reflects cell survival after physical injury, it underestimates the effect of chemotherapy on cell reproductive potential in vitro. However, FDA is highly correlated with histological assessment of tumor viability after chemotherapy in vivo. It is apparent that the methodology chosen for determination of viability should be appropriate for the type of experimental injury and should analyze the cell function (i.e., metabolic activity or reproductive capacity) that is appropriate for the experimental model.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ [u.a.] : Wiley-Blackwell
    Journal of Orthopaedic Research 6 (1988), S. 51-57 
    ISSN: 0736-0266
    Keywords: Osteosarcoma ; Chemotherapy ; Flow cytometry ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Although chemotherapeutic drugs are frequently administered to patient with osteosarcoma, there has been little research into the effect of cytotoxic drugs on osteosarcoma cell biology. The effect of two drugs (Adriamycin and bleomycin) on cell cycle kinetics was investigated in vitro in an established line of human osteosarcoma cells and in vivo using the Dunn osteosarcoma model. The cell cycle changes were consistent with G2 arrest for both drugs in vivo and in vitro. The alteration in cell cycle distribution was correlated with inhibition of 3H-thymidine incorporation in vitro. In vivo, the greater change in cell cycle distribution caused by Adriamycin was reflected in the increased inhibition of tumor growth found with this drug.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ [u.a.] : Wiley-Blackwell
    Journal of Orthopaedic Research 7 (1989), S. 468-473 
    ISSN: 0736-0266
    Keywords: Sarcoma ; Growth factor ; Flow cytometry ; Tumour ploidy ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Cell lines derived from human sarcomas have been previously shown to produce a protein growth factor which, similar to platelet-derived growth factor (PDGF), can induce competence for mitosis in fibroblasts. Whether this factor production is an important feature of sarcomas in vivo or simply an artefact caused by long-term culture conditions is unclear, however. We demonstrated growth factor activity in conditioned medium from six of 11 primary sarcoma cultures, utilizing flow cytometric analysis of DNA to monitor the presence of sarcoma cells in cultures. Cells isolated from control tissues failed to show a similar mitotic effect.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...