Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Pure and applied geophysics 80 (1970), S. 38-47 
    ISSN: 1420-9136
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Description / Table of Contents: Summary A procedure for determining the best fitted parameters of a three layer case to a given travel time curve by the least squares method is described. At most three parameters can be calculated, the other three have to be known. Refraction is taken into account exactly. The calculations have to be made with the aid of a computer. The unknown parameters can be determined approximatively by simple formulas.
    Notes: Zusammenfassung Ein Verfahren zur Bestimmung der im Sinne der Methode der kleinsten Quadrate bestangepassten Schichtparameter an eine gemessene Laufzeitkurve wird angegeben. Es können höchstens drei Parameter berechnet werden, die drei übrigen Parameter müssen bekannt sein. Die Brechung wird exakt berücksichtigt. Das Verfahren ist für Berechnung durch Computer geeignet. Einfache Formeln gestatten eine angenäherte Bestimmung der unbekannten Parameter.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Pure and applied geophysics 69 (1968), S. 205-228 
    ISSN: 1420-9136
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Description / Table of Contents: Résumé On décrit la construction d'un rock generator. Les échantillons de forme cylindrique ont un diamètre de 4.2 cm et une longueur de 3.6 cm. La vitesse de rotation est de 7200 tours/minute; l'appareil est actionné par un moteur électrique. On peut mesurer des aimantations rémanentes de 10−7Γ à 10−2Γ. Pour des aimantations supérieures à 2·10−6Γ, l'erreur moyenne est de 0.5° pour la direction et de 3% pour l'intensité, en utilisant des échantillons homogènes. Pour des échantillons inhomogènes, les erreurs peuvent atteindre 6° et 13% dans les cas les plus défavorables. On discute aussi les principes théoriques les plus importants sur lesquels est basée la construction du rock generator. En particulier, une méthode est développée qui permet de calculer les erreurs de mesure provenant d'une distribution inhomogène de l'aimantation des échantillons. Les dimensions des bobines, tout en tenant compte de certaines conditions supplémentaires pour le diamètre et l'espacement, sont fixées de manière à obtenir des erreurs minima. On compare ces bobines à d'autres bobines possédant un rapport maximum signal/bruit. Ces dernières sont dimensionnées à l'aide d'un graphique pouvant être utilisé sous différentes conditions supplémentaires pour le diamètre et la longueur. Enfin sont discutées différentes méthodes permettant de réduire le ronflement.
    Abstract: Summary The design of a rock generator is described. Cylindrical specimens of diameter 4.2 cm and length 3.6 cm are used. The apparatus is driven with a speed of 7200 r.p.m. by an electromotor. Magnetizations of 10−7Γ to 10−2Γ can be measured. For magnetizations stronger than 2·10−6Γ the mean error is less than 0.5° for direction and 3 percent for intensity when using homogeneous specimens, and 6° and 13 percent respectively with inhomogeneous specimens. The most important theoretical aspects of a rock generator are also discussed. Especially a method is developed for evaluating the errors due to an inhomogeneous magnetization. The coils are designed for minimum measuring errors while considering certain secondary conditions for diameter and distance. These coils are compared to other coils with maximum sensitivity. The latter are designed by means of a graph usable for a large range of secondary conditions for diameter and coil length. Finally different methods for reducing hum are discussed.
    Notes: Zusammenfassung Es wird der Aufbau eines Rock Generators beschrieben. Die zylindrischen Proben haben einen Durchmesser von 4.2 cm und eine Länge von 3.6 cm. Die Drehzahl beträgt 7200 U/min, den Antrieb besorgt ein Elektromotor. Es können Magnetisierungen von 10−7Γ bis 10−2Γ gemessen werden. Für grössere Magnetisierungen als 2·10−6Γ beträgt der mittlere Messfehler an homogenen Proben etwa 0.5° für die Richtung und 3% für den Betrag. An inhomogen magnetisierten Proben können im ungünstigsten Fall Fehler von 6° bzw. 13% auftreten. Es werden auch die wichtigsten theoretischen Grundlagen eines Rock Generators diskutiert. Insbesondere wird eine Methode zur Berechnung der Messfehler entwickelt, die durch eine inhomogene Magnetisierung der Probe verursacht werden. Die Spulen werden unter Einhaltung gewisser Bedingungen für Durchmesser und Abstand für minimale Messfehler dimensioniert. Diese Spulen werden mit anderen Spulen mit Hilfe eines Nomogramms dimensioniert, das unter verschiedenen Nebenbedingungen für Durchmesser und Länge benutzbar ist. Schliesslich werden verschiedene Methoden zur Verminderung der Brummspannung diskutiert.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    International journal of cosmetic science 18 (1996), S. 0 
    ISSN: 1468-2494
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The protocol described here has been developed to measure the stability of UV-B filters; a modified version is recommended for UV-A filters. It should be considered as a tool to predict the effectiveness remaining after exposure to UV-A and UV-B light. It is a simple and reliable in vitro model simulating conditions of actual use. The results show that each filter requires an appropriate choice and fine tuning of reproducible analytical conditions. While absolute values are directly influenced by uncertainties in irradiance (dosimetry), comparative measurements with respect to a known standard are very reliable.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford [u.a.] : International Union of Crystallography (IUCr)
    Acta crystallographica 41 (1985), S. 1694-1696 
    ISSN: 1600-5759
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford [u.a.] : International Union of Crystallography (IUCr)
    Acta crystallographica 43 (1987), S. 1243-1245 
    ISSN: 1600-5759
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1615-6714
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Long-term outcome of orthodontic care systems may be studied by examining malocclusion and treatment need in groups of treated and untreated adults. The objective of the present work was to investigate the professionally defined need as well as the need perceived by the individuals in an attempt to study the outcome of orthodontic services. The material comprised data from 111 individuals collected from a random sample of 35-year-olds from Oslo, Norway. From a clinical examination and measurements on dental study casts, the subjects were classified into either of 4 levels of need according to the Need for Orthodontic Treatment Index (NOTI) used by the Norwegian Health Insurance System. Perceived need for treatment was analyzed from responses to questions about satisfaction with dental appearance and desire for orthodontic treatment presented in a questionnaire. Satisfaction with dental appearance was recorded in 85% and 92% of untreated and previously treated, respectively. Desire for treatment was expressed by 19% of the untreated and 3% of the treated individuals. Occlusal anomalies were present among both the treated and untreated subjects, and the clinical significance of the malocclusion traits observed is discussed.
    Notes: Zusammenfassung Anhand einer Untersuchung der Zahnfehlstellung und des Behandlungsbedarfs bei Gruppen von behandelten und unbehandelten Erwachsenen können die langfristigen Ergebnisse der kieferorthopädischen Therapie erforscht werden. Ziel der vorliegenden Arbeit war es, die Ergebnisse der kieferorthopädischen Behandlungen zu untersuchen, um sowohl den ärztlich definierten als auch den vom einzelnen empfundenen Bedarf zu ermitteln. Das Untersuchungsmaterial umfaßt Daten von 111 unselektierten 35jährigen aus Oslo, Norwegen. Anhand einer klinischen Untersuchung und Analysen von dentalen Studienmodellen wurden die Probanden in eine von vier Bedarfskategorien nach dem norwegischen Indikationssystem („Need for Orthodontic Treatment Index“ [NOTI]), das von der staatlichen Sozialversicherung angewendet wird, eingeteilt. Mittels eines Fragebogens wurde nach der Zufriedenheit mit der eigenen dentofazialen Ästhetik und dem Wunsch, sich einer kieferorthopädischen Behandlung zu unterziehen, gefragt. Danach wurden die Antworten hinsichtlich des vom einzelnen empfundenen Behandlungsbedarfs analysiert. Zufriedenheit mit der eigenen dentofazialen Ästhetik wurde bei 85% der unbehandelten und 92% der früher behandelten Probanden festgestellt, während der Wunsch nach einer Behandlung bei 19% der unbehandelten und 3% der behandelten Probanden bestand. Okklusale Anomalien wurden sowohl bei behandelten als auch bei unbehandelten Probanden festgestellt, und die klinische Signifikanz der Befunde in bezug auf Zahn/Kiefer-Fehlstellungen wird erörtert.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...