    Notes: To determine whether the measurement of specific markers of inflammatory cells in peripheral blood might be used to detect the inflammatory activity in the airways in asthma induced by toluene diisocyanate (TDI). we measured the levels of eosinophil cationic protein (ECP), histamine and tryplase in peripheral blood before and during inhalation challenge with TDI or methacholine in two groups of subjects who exhibited or did not exhibit an asthmatic reaction after exposure to toluene diisocyanate in the laboratory. When the subjects developed a late asthmatic reaction after exposure to TDI, the\ showed an increase in their ECP serum levels. By contrast, there were no signilicam changes in serum ECP levels after exposure to TDI in the control group or after methacholine challenge in either group. Tryptase levels in serum were not detectable before or during inhalation challenge with TDI or methacholinc. There was no significant increase in plasma histamine levels during inhalation challenge with TDJ or methacholine. These results suggest that eosinophils arc ‘activated’ in subjects who develop a late asthmatic reaction after exposure to TDI and that the measurement of ECP levels in peripheral blood may be a useful marker to monitor airway inflammation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Allergy 59 (2004), S. 0 
    ISSN: 1398-9995
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1398-9995
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: In order to establish the most efficient thresholds for serum allergen-specific IgE measured by the Pharmacia CAP System, a “second-generation”in vitro method, we evaluated results from 89 subjects with suspected inhalant allergies, using receiver-operating characteristic (ROC) curve analysis. Sera samples were analyzed by the Pharmacia CAP System for specific IgE, the choice of allergens to be tested being based upon the symptoms and clinical history of each patient. Results were analyzed by ROC analysis for the five most representative allergens, cat dander (e1), Dermatophagoides pteronyssinus (dl), Lolium perenne (g5), wall pellitory (W19), and wormwood (w5). The areas under the ROC curves were found to be satisfactory, ranging from 0.931 (e1) to 0.974 (g5) when we excluded w5, which had a significantly smaller area (0.81). To establish the most efficient threshold for each allergen, we calculated the clinical sensitivity, specificity, efficiency, and negative and positive predictive values. The thresholds giving a higher diagnostic efficiency were as follows: 0.40 kUa/l for dl, 0.55 kUa/l for g5 0.50 for el, 0.65 kUa/l for w19, and 1.00 kUa/l for w5. It is concluded that quantitative reporting of specific IgE measurement has numerous advantages, but the choice of the positive threshold seems to be a prerequisite for obtaining the optimal clinical efficiency. It is also suggested that a specific threshold should be adopted for each allergen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Allergy 50 (1995), S. 0 
    ISSN: 1398-9995
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We evaluated the ENEA System, a fully automated instrument for the measurement of specific IgE antibodies. The instrument dispenses sera and reagents, incubates, washes, and reads and prints results automatically. The “core” of the instrument is the reactive unit called ACE (Allergy Chamber Enzymatic), which is a new solid phase to which the allergens are linked. The system uses calibration curves specific for the major allergen families, and data are supplied qualitatively (five classes) and quantitatively. We evaluated the analytic efficiency of the system and its correlation with the in vivo test (skin prick test (SPT)) results in 60 patients with inhalant allergic diseases and in 20 controls. Results: 450 results were available within 4 h. A satisfactory within-run (CVs between 1.58 and 6.2%) and between-run (CVs 6.3–11.5%) precision was found. No significant earn-over was observed. A wide linearity of the assay was demonstrated. With the concordance between the clinical history and SPT as the reference value, the clinical sensitivity of the ENEA System was 84.1 %, the specificity 82.8%, and the overall efficiency 83.4%. Finally, a good agreement with the results of another technique for the in vitro measurement of specific IgE (Pharmacia CAP System) was proven.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1398-9995
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The objectives of this study were to determine: 1) levels of tear eosinophil cationic protein (ECP) in patients with vernal keratoconjunctivitis (VKC); 2) the effect of pharmacologic therapy on ECP release; and 3) the correlation of this mediator with the severity of the disease. Tears were collected from 10 controls and 20 VKC patients before and after therapy for cytologic analysis and ECP measurement by radioimmunoassay. Ocular signs and symptoms were evaluated before tear collection. Mean ECP levels in controls were 7.5 ± 0.4 μg/l, and in VKC patients, 988.3 ± 128 μg/l before therapy (P〈0.001) and 566.3 ± 121 μg/l after therapy (P〈0.005). In dexamethasone (Dex) 0.1%, or cyclosporin A (CsA) 2%, patients (five per group), tear ECP decreased significantly after 7–14 days of treatment. Disodium cromoglycate (DSCG) 4% (five patients) for 14 days did not significantly affect ECP levels. ECP levels were significantly correlated with allergic signs (P〈0.001), symptoms (P〈0.001), and the number of eosinophils in tears (P〈0.005). The results of this study suggest that tear ECP levels accurately reflect the clinical status of VKC patients. The measurement of ECP may prove useful not only in the diagnosis and monitoring of allergic disease, but also as an objective parameter for the evaluation of new antiallergic therapies.