Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 525-530 
    ISSN: 0935-6304
    Keywords: Packed capillary liquid chromatography ; temperature programming ; Fourier-transform infrared spectroscopy ; polymer additives ; pneumatic nebulization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Temperature-programmed packed capillary liquid chromatography has been coupled off-line to Fourier-transform infrared spectroscopy, utilizing a commercially available interface with a pneumatic nebulizer rebuilt to handle low flow rates at elevated temperatures. The modified interface showed excellent performance with regard to non-aqueous reversed phase separations of polymer additives, resulting in constructed Gram-Schmidt chromatograms comparable to chromatograms obtained using UV detection. The spray of the in-house constructed nebulizer was not influenced by temperature changes of the column effluent, and hence temperature-programmed gradient separations could be used successfully. The relative standard deviation of peak height was 4.4% (n = 5) and the mass limit of detection was determined to be about 40 ng, using a polymer antioxidant as model compound. The present instrumental coupling has been used for characterization of the antioxidant Irgafos P-EPQ.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0935-6304
    Keywords: Large volume injection ; packed capillary LC ; temperature programming ; retinyl esters ; vitamin A ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A non-aqueous isocratic reversed-phase packed capillary high performance liquid chromatography method for the determination of retinyl esters, utilizing temperature programming and on-column focusing large volume injection, has been developed. The stationary phase material was C30, and the mobile phase consisted of acetonitrile-dichloromethane (70 : 30, v/v). A three-step temperature program, starting at 10°C for 10 min, then 1°/min to 30°C, and finally 2.5°/min to 70°C, was found most appropriate. Compared to an isothermal separation at 25°C, this temperature program provided improved peak resolution, enhanced peak shapes of the last eluting compounds, and a reduction of the overall elution time. A mass limit of detection of 27 pg was found with respect to retinyl palmitate, using UV detection with an “U” shaped flow cell at 327 nm. This corresponds to a concentration limit of detection of 2.7 pg/μL, when utilizing an injection volume of 10 μL. The concentration of retinyl palmitate in arctic seal liver samples was estimated to be 62.6 μg/g liver.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 386-388 
    ISSN: 0935-6304
    Keywords: On-line SFE-SFC ; organometallics ; purity testing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: No abstract
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...