Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 2 (1981), S. 273-292 
    ISSN: 1572-9559
    Keywords: Filters ; Infrared ; Metallic mesh
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract By using a Michelson interferometer in the asymmetric mode with helium cooled bolometer, we have measured with precision the complex transmittance and reflectance of metallic meshes in the wavelength region 0.7〈λ/g〈5, where λ is the wavelength, and g is the period of the mesh. For λ≅g we observed a minimum power reflectance smaller than 10−4 at normal incidence. The important variations of the transmittance with the angle of incidence have been thoroughly investigated. Changes around the maximum transmittance are explained by the propagation of diffracted modes. Phase measurements show that a sharp dip appearing at λd with 1〈λd/g〈1.8 is related to the finite thickness of the mesh. From our measurements as well as other data precedently published it appears that there is a linear dependance between λd/g and the relative width of the slots of the mesh. All these deviations from classical models must absolutely be taken in account when designing high performances far infrared filters.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-093X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract GOLF in-flight commissioning and calibration was carried out during the first four months, most of which represented the cruise phase of SOHO towards its final L1 orbit. The initial performance of GOLF is shown to be within the design specification, for the entire instrument as well as for the separate sub-systems. Malfunctioning of the polarising mechanisms after 3 to 4 months operation has led to the adoption of an unplanned operating sequence in which these mechanisms are no longer used. This mode, which measures only the blue wing of the solar sodium lines, detracts little from the detection and frequency measurements of global oscillations, but does make more difficult the absolute velocity calibration, which is currently of the order of 20%. Data continuity in the new mode is extremely high and the instrument is producing exceptionally noise-free p-mode spectra. The data set is particularly well suited to the study of effects due to the excitation mechanism of the modes, leading to temporal variations in their amplitudes. The g modes have not yet been detected in this limited data set. In the present mode of operation, there are no indications of any degradation which would limit the use of GOLF for up to 6 years or more.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...