Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of orthopaedic surgery & traumatology 10 (2000), S. 249-256 
    ISSN: 1432-1068
    Keywords: Knee arthroplasty ; Distal femoral fracture
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Distal femoral fractures following knee arthroplasty are uncommon. The reported frequency ranges from 0.3 to 2.5%. Treatment of such fractures remains controversial. Both operative and nonoperative methods have been proposed Conservative treatment (used for undisplaced fractures) is very demanding for patient and surgeon. Open reduction and fixation is often preferred in displaced and unstable fractures but complications are not rare and may be very severe. Good clinical results have been recently reported with intramedullary nailing in both anterograde and retrograde manner. Revision arthroplasty is also a possible treatment if there is component loosening. The purpose of this study is to report our experience with the management of distal femoral fractures after knee arthroplasty in 37 cases. We stress the difficulty of treating these fractures and the poor results obtained in terms of knee function.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of orthopaedic surgery & traumatology 7 (1997), S. 130-134 
    ISSN: 1432-1068
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of orthopaedic surgery & traumatology 2 (1992), S. 61-70 
    ISSN: 1432-1068
    Keywords: Cimentless ; Knee ; Prosthesis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The purpose of this survey was to study the results observed in 115 patients with unicompartmental arthroplasty of the knee (PCA) performed at least two years previously and using uncemeted prostheses; all patients were seen again at follow-up and X-rays were obtained. Good and excellent results were found in 81% of cases. Precise information about angle, axis and prosthetic parts is given. Ten patients had to be reoperated on (9,5% of cases) owing to loosening of medial femoral prosthesis or because of recurring genu varum (absence of ACL). Medial prostheses (73% of cases) and lateral prostheses differed not only with respect to their behaviour but also to the preoperative morphotype. Finally, information is given about the handling of the patella and the indications.
    Notes: Résumé Entre 1985 et 1989, 115 prothèses unicompartimentales (PUC) de type PCA ont été mises en place dans notre établissement. Il s'est agit deux fois sur trois d'une PUC interne pour laquelle l'étiologie principale était la gonarthrose. L'analyse sur ordinateur des résultats selon le score 100 points de Hungerford a permis de retrouver 81,7% d'excellents et de bons résultats. Dans 9,5% la prothèse unicompartimentale a dû être changée, le plus souvent à cause d'un descellement fémoral. L'étude de la série permet d'analyser les causes d'échecs, d'objectiver les différences réelles existant entre les PUC internes et externes et de confirmer la qualité des résultats de l'arthroplastie unicompartimentale sous réserve d'une indication correcte (persistance du LCA) et la fiabilité de la mise en place sans ciment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European journal of orthopaedic surgery & traumatology 2 (1992), S. 55-60 
    ISSN: 1432-1068
    Keywords: Artificial ligament ; Knee ; Surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The experience of the surgeons at the Clinique du Parc to Lyon, based on over 2,000 implanted artificial ligaments for replacement of the anterior or posterior cruciate ligament of the knee, dates back over 10 years to 1980. Today, this experience makes, it is possible to document the indications of this type of surgical technic which is still the subject of much controversy and dispute. In order to improve the analysis of clinical results, over the last year or so, the authors have computerized data and systematically reexamined all patients operated on and not lost to follow-up. The results obtained for the 325 ABC ligaments thus reexamined are presented here and support the following indications: recently-developed laxity of the anterior ligaments, in patients over 27 years of age, whether the impairment be isolated as in the athlete, or complex, most often inserted arthroscopically; certain types of chronic laxity of the anterior ligament. Contraindications are documented. In cases of chronic instability of the posterior ligament combining rupture of the posterior cruciate ligament with postero-lateral impairment, the artificial ligament is used in combination with valgus osteotomy.
    Notes: Résumé Remontant à 1980, il y a plus de dix ans, portant sur plus de 2 000 ligaments artificiels implantés pour remplacer le ligament croisé antérieur ou le croisé postérieur du genou, l'expérience des chirurgiens de la Clinique du Parc à Lyon permet aujourd'hui de préciser les indications de ce type de technique chirurgicale dont l'utilisation suscite toujours controverses et discussions. Pour améliorer l'analyse des résultats cliniques, les auteurs ont entrepris de mettre en informatique et de revoir systématiquement depuis plus d'un an la majorité des malades opérés et retrouvés. Les résultats de 325 ligaments ABC ainsi revus sont présentés et servent de support aux indications : dans les laxités antérieures fraîches, volontiers après 27 ans, que la lésion soit isolée chez le sportif ou complexe, le plus souvent sous arthroscopie; dans certaines laxités antérieures chroniques. Les contre-indications sont précisées. Dans les laxités postérieures chroniques associant une rupture du ligament croisé postérieur à une lésion postéro-externe, le ligament artificiel est utilisé, associé à une ostéotomie de valgisation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    European journal of orthopaedic surgery & traumatology 3 (1993), S. 179-181 
    ISSN: 1432-1068
    Keywords: Knee prostheses ; Prothèses de genou
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé L'analyse des reprises de 876 prothèses du genou comportant 239 prothèses du type charnière ou assimilé et 637 prothèses à glissement, est présentée. On a séparé les 239 prothèses de type charnière, totalisant en 39 reprises (16,3 %) des 637 prothèses à glissement totalisant 49 reprises (7,5 %). Dans les deux groupes de prothèses, ont été précisés la date de survenue des complications ayant nécessité la reprise ainsi que la cause de cette complication et le résultat de la reprise chirurgicale. Il apparaît que dans les prothèses de type charnière, l'infection est le plus souvent en cause (près d'une fois sur deux) bien avant les complications rotuliennes ou mécaniques. Les résultats sont, dans ce type de reprises, dans l'ensemble médiocres (40 % de bons et excellents) . Dans les prothèses à glissement, c'est essentiellement le descellement d'un élément fémoral ou tibial qui explique la reprise (26,5 %) des cas, l'infection n'étant en cause que dans 20,4 % ; les problèmes rotuliens ou les raideurs ayant justifié une arthrolyse, non moins fréquente. Dans ce type de prothèses la reprise a été le plus souvent précoce (67,2 % avant la fin de la deuxième année). Les résulats sont bons dans près de 60 % des cas. L'analyse de ces reprises de prothèses du genou vient confirmer les données classiques des grandes séries. L'augmentation probable des reprises du fait de l'augmentation de la pose des prothèses du genou justifie, dès aujourd'hui, l'adoption d'une grille précise des complications si l'on veut, à l'avenir, procéder à une analyse objective.
    Notes: Abstract The analysis of reoperation in a series of 876 knee-prostheses consisting of 239 hinge-like or similar prostheses and 637 sliding prostheses is presented. The group of 239 hingelike prostheses totalled 39 reoperations (16.3%), whilst the 637 sliding prostheses totalled 49 reoperations (7.5%). For both groups of prostheses, we indicate the date of onset and the cause of the complications that made reoperation necessary, as well as the result of the second procedure. It appears that the hinge prostheses are most often affected by infection (50% of cases), rather than patellar or mechanical complications. On the whole, in this type of reoperation, the results are poor (40% rated good and excellent). With sliding prostheses, it was essentially the loosening of the tibial or femoral element which prompted reoperation (26.5% of cases) whilst infection affected only 20.4% of cases. Patellar problems or stiffness of the knee justifying arthrolysis were equally frequent. With this type of prosthesis, reoperation was most often performed at an early stage (67.2% before the end of the second year). Resultas are good in nearly 60% of cases. Analysis of these reoperations for knee-prostheses confirms the conventional data of larger series. The probable future increase in the number of reoperations, in view of the increasing number of patients implanted with knee-prostheses, justifies the adoption of a precise chart of the related comlications if objective analyses are to be made in the years to come.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    European journal of orthopaedic surgery & traumatology 3 (1993), S. 193-196 
    ISSN: 1432-1068
    Keywords: Knee prostheses ; Prothèses de genou
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Entre le 17 mai 1990 et le 31 décembre 1990, 105 prothèses compartimentales THEMIS ont été mises en place dans notre groupe (AGREG1). Il s'est agi deux fois sur trois d'une arthroplastie pour lésion en varus pour laquelle l'étiologie principale était la gonarthrose. L'analyse sur ordinateur des résultats selon le score 100 points de Hungerford a permis de retrouver 89,3 % de bons et excellents résultats. Dans 5,7 % des cas, le malade a été réopéré. Il s'agissait essentiellement d'infection (2 cas) et de raideur (2 arthrolyses). L'analyse de la série confirme la qualité des résultats cliniques et radiographiques, en particulier au niveau de l'intégration osseuse des composants métalliques titane. Ces composants, mis en place grâce à une instrumentation ancillaire excellente, confirment la parfaite qualité de cette arthroplastie dont les éléments ont été mis sans ciment.
    Notes: Abstract Between 17 May 1990 and 31 December 1990, 105 Themis threecomponent prostheses were implanted by our group (AGREG). In two out of three cases, arthroplasty was performed to treat genu varum, the aetiology of which was degenerative arthritis of the knee. Computerized analysis of data, according to Hungerford's 100 point score scale, showed good and excellent results in 89.3% of cases. Patients were reoperated on in 5.7% of cases. The reason was essentially infection (2 cases) and stiffness (2 cases of arthrolysis). Analysis of this series confirms the excellence of clinical and radiographic results, in particular at the site where the titanium components integrate with bone. These components, implanted with excellent ancillary instruments, ensure the perfect quality of those arthroplasties that were performed without cement.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    European journal of orthopaedic surgery & traumatology 3 (1993), S. 147-148 
    ISSN: 1432-1068
    Keywords: Knee prostheses ; Prothèses de genou
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Entre mai 1984 et décembre 1988, 92 prothèses PCA PRIMARY ont été mises en place. Il s'agissait, dans plus de 80 % des cas, d'une gonarthrose essentielle, en varus dans 70 % des cas. Quatre-vingt malades ont été réexaminés et radiographiés pour cette étude (87 % des cas opérés) avec un recul minimum de trois ans. L'analyse sur ordinateur des résultats selon les scores 100 points d'Hungerford a permis de retrouver 81,2 % de bons et excellents résultats. Dans 7,5 % des cas le malade a été réopéré (6 cas). Il s'agit essentiellement de descellement aseptique tibial ou rotulien deux fois et de deux changements de prothèse. L'analyse de cette série confirme les très bons résultats cliniques de cette prothèse, la première à disposer d'une instrumentation ancillaire universelle, conservant le croisé postérieur et dont les éléments ont été mis en place le plus souvent sans ciment (70 % des cas).
    Notes: Abstract Between May 1984 and December 1988, 92 PCA Primary prostheses were fitted. In more than 80% of cases, the indication was primary degenerative arthritis of the knee, associated with genu varum in 70% of cases. In this study, 80 patients were reexamined and X-rayed (87% of operated cases) with a minimum three-year follow-up. Computerized analysis of data, according to Hungerford's 100 point score scale, showed good and excellent results in 81.2% of cases. 7.5% of all cases (6 cases) had to be reoperated on. Reasons for reoperation were aseptic tibial or patellar loosening, which occurred twice, and two replacements of prothesis. Analysis of this series confirms the very good clinical results achieved with this type of prosthesis. Representing the first type of prosthesis to be installed with the universal instruments, it makes it possible to preserve the posterior cruciate ligament, and, in most cases, the components were inserted and fixed without cement (70% of cases).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    European journal of orthopaedic surgery & traumatology 8 (1998), S. 1-6 
    ISSN: 1432-1068
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    European journal of orthopaedic surgery & traumatology 8 (1998), S. 107-123 
    ISSN: 1432-1068
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biochemical and Biophysical Research Communications 175 (1991), S. 451-458 
    ISSN: 0006-291X
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...