  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 102 (1980), S. 7441-7444 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 60 (1989), S. 3265-3269 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The electronics for the microchannel plate photomultiplier tubes used in the LIDAR (Light Detection and Ranging) Thomson scattering diagnostic on the JET tokamak are described. It is shown how the microchannel plate photomultiplier tubes are gated with a very small coupling between gate signal and output, and how ≈300 V transient pulses with rise times of 230 ps are clipped to safe levels of ≈40 V.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 59 (1988), S. 1451-1456 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: By combining the time-of-flight or LIDAR principle with a Thomson backscatter diagnostic, spatial profiles of the electron temperature and density are measured in a magnetically confined fusion plasma. This technique was realized for the first time on the JET tokamak. A ruby laser (3-J pulse energy, 300-ps pulse duration, 0.5-Hz repetition rate) together with a 700-MHz bandwidth detection and registration system yields a spatial resolution of about 12 cm. A spectrometer with six channels in the wavelength range 400–800 nm gives a dynamic range of the temperature measurements of 0.3–20 keV. The stray light problem in the backscatter geometry is overcome by spectral discrimination and gating of the photomultipliers. A ruby filter in the spectral channel containing the laser wavelength allows calibration of the vignetting along the line of sight by means of Raman scattering, enabling the measurement of density profiles. The low level of background signal due to the short integration time for a single spatial point yields low statistical errors (ΔTe /Te ≈6%, Δne /ne ≈4% at Te =6 keV, ne =3×1019 m−3 ). Goodness-of-fit tests indicate that the systematic errors are within the same limits. The system is described and examples of measurements are given.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 86 (1979), S. 0 
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A successful pregnancy in a woman with Turner's syndrome with a 45, X/46,XX karyotype is described. The literature contains reports of a total of nine pregnancies in seven women with a 45,X karyotype and 56 pregnancies in 23 women with mosaicism and a 45,X cell line, as well as a 46,XX and/or 47,XXX cell line. Fifteen of the latter 56 pregnancies ended in spontaneous abortion (27 per cent), and four ended in the delivery of a stillborn child; 12 of the 37 liveborn infants (32 per cent) had a physical or mental abnormality, and 8 (22 per cent) had a chromosome abnormality. Three had Down's syndrome, and five had a 45,X cell line. Due to the relatively high (8 per cent) incidence of Down's syndrome among liveborn infants of women with Turner's syndrome, amniocentesis for fetal karyotyping should be advised.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 276 (1978), S. 167-168 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The experimental system has been described previously4. Excited states were produced by electron irradiation with a pulse of high energy electrons. Concentrations and kinetics of the transient species were established by optical absorption spectroscopy, and a pulsed dye laser and an optical ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-1203
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary As part of an ongoing study of the influence of environmental factors on pregnancy, childbirth, and fetuses, comparisons have been made between incidences in 1969–1974 and in 1980–1982 of chromosome aberrations in liverborn children in the same area of Denmark. The incidence of chromosome aberrations in the first period was 2.6 per 1000, compared with 4.1 per 1000 during the latter period. However, the difference was mainly due to an increase in inversions, and this in turn was due to a difference in chromosome staining methods between the two periods. It is concluded that the Danish study and similar studies in the United States, Canada, and Scotland indicate that early detection of chromosome aberrations by chromosome examination at birth is indicated in order to be able to inform and counsel parents of children with chromosome aberrations. Chromosome examination at birth is also of importance in the diagnosis of structural inheritable chromosome aberrations and consequent family investigation and genetic counseling.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Human genetics 〈Berlin〉 59 (1981), S. 194-200 
    ISSN: 1432-1203
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary A chromosome examination was made on 11,148 consecutively live-born children: 93 had a chromosome abnormality and 192 a chromosome variant. The physical aspects of the children with chromosome abnormalities and variants were compared with those of the children with normal karyotypes. Children with aneuploid or unbalanced chromosome abnormalities were more frequently immature or not fully developed at birth than those with normal karyotypes. Birth weight was lower in children with all types of chromosome abnormalities, including reciprocal translocations and chromosome variants. The low birth weight in children with chromosome variants was mainly due to the low birth weight of children with G variants. These children were also subject to a higher frequency of special delivery treatment. Heart disorders were increased in children with aneuploid or unbalanced chromosome abnormalities. The frequency of foetal erythroblastosis was increased in children with short Y as well as in children with acentric fragments. Neonatal mortality was higher in children with aneuploid or unbalanced chromosome abnormalities than in children with normal karyotypes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Journal of Raman Spectroscopy 11 (1981), S. 24-26 
    ISSN: 0377-0486
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The resonance Raman spectrum of the transient thioether radical cation dimer complex |(CH3)2S|2+·, generated by electron irradiation of an aqueous solution of dimethylsulfide and recorded by optical multichannel detection, is reported. Vibrational bands at 276 cm-1 and 139 cm-1 were detected and are assigned to the stretching mode of the quasi-three-electron S—S bond and a δ(CSS) deformation mode, respectively.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...