Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Solid phase extraction ; PCBs in cod-liver oil ; GC/MS identification
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A group of non-planar PCBs (IUPAC nos. 28, 52, 101, 118, 138, 153, and 180) was identified in a cod-liver oil product by using high resolution gas chromatography-mass spectrometry (HRGC/MS) in electron impact (EI) and negative chemical ionization (NCI) modes. The cod-liver oil samples were prepared either in a cyano column by high performance liquid chromatography (HPLC) or by a solid phase extraction (SPE) clean-up procedure that included e.g. purified charcoal treatment. The two methods of sample preparation were evaluated on the basis of the detectabilities of the congeners. The GC/MS-SIM method allowed quantitative monitoring of congeners nos. 52, 101, 118, 138, 153, and 180 at low concentration levels. Detection limits were 1.2 pg and 130 fg (m/z 292.00) in EI and NCI modes, respectively. The determination levels in EI and NCI were 1.8 pg and 290 fg in HPLC followed by HRGC/MS and 170 pg and 27 pg in SPE followed by HRGC/MS. The linear range was from 5.0 pg/μl to 1.0 ng/μl and from 1.0 pg/μl to 1.0 ng/μl in EI and NCI modes, respectively. In addition, the co-planar PCBs, PCDDs, and PCDFs were also screened and two of the chlorinated furanes were identified by HRGC/MS-NCI after separation from non-planar PCBs by SPE. In this case the only congeners that could be quantified were 2,3,4,7,8-PCDF and 1,2,3,4,6,7,8-HCDF, the detection limit for them being 740 fg (m/z 351.90) with NCI. SPE allows the separation of the planar and non-planar compounds, but LC separation is more effective for separation of the compounds of interest from the matrix. LC clean-up is easier and faster to perform than SPE clean-up.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 319 (1984), S. 149-152 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The decay properties of theJ π=1/2+,E exc=1,098 keV state in203Bi were studied. The state was populated via the204Pb(p, 2n) reaction and the activity was studied with the ion guide isotope separator on-line system IGISOL. The half-life of the 1/2+ state was measured to beT 1/2=303 ±5 ms. From this value the partial half-lives of the three depopulating branches 1/2+ →7/2− (E3), 1/2+→5/2− (E3 +M2) and 1/2+→9/2 g.s. − (M4) were deduced. Since all the transitions are configuration forbidden in first order, a detailed study of second-order shell-model configuration mixing could be performed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...