Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 2 (1983), S. 608-616 
    ISSN: 0392-6737
    Keywords: Biomagnetism (including magnetocardiography) ; Superconducting devices ; superconducting magnets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Si è trovato che la velocità di decadimento del campo residuo ottenuto tramite magnetizzazione delle particelle ferromagnetiche trattenute nei polmoni dei saldatori è associato a fattori come la quantità di polvere trattenuta, il curriculum lavorativo e la consuetudine di fumare. Una velocità di decadimento piú rapida appare correlata con un piú rapido smaltimento delle particelle di fumo di saldatura nei fumatori.
    Notes: Summary It was found that the rate of decay of the remanent field obtained through magnetization of ferrimagnetic particles retained in the lungs of are welders is associated with factors such as amount of dust retained, occupational history and smoking habits. A faster decay rate was found to correlate with a faster clearance of welding fume particles in smokers
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 22 (1984), S. 453-457 
    ISSN: 1741-0444
    Keywords: Estimation ; Fatigue ; Force ; Intramuscular pressure ; Muscle ; Myoelectric
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Estimation of muscle force from the root mean square value of the myoelectric signal is limited to nonfatiguing contractions because of the change in the signal value that occurs with fatigue. In this paper the total intramuscular pressure is proposed as a muscle force estimator. Using a catheter, intramuscular pressure was measured for isometric time-varying force contractions and compared with the myoelectric signal mean absolute value. Results show that the pressure provides a linear estimator for load with an estimation error which is less than that obtained from the myoelectric signal. The myoelectric load estimator changes with fatigue but there is no significant change in the pressure load estimator.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 83 (2000), S. 223-230 
    ISSN: 1439-6327
    Keywords: Key words Intramuscular pressure ; Rotator cuff ; Working postures ; Shoulder tendinitis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In work engaging the upper extremities, the musculoskeletal system of the shoulder is sometimes exposed to prolonged excessive load, leading to musculoskeletal disorders of the shoulder. One way of reducing work-related shoulder disorders is to establish guidelines for working postures. The purpose of this study was to identify harmful working positions, by performing a comprehensive survey of the intramuscular pressure (IMP) in the infra- and supraspinatus muscles in relation to different arm positions and external loads. Ten healthy males participated, and the IMP in the infra- and supraspinatus muscles was studied in a total of 112 combinations of arm positions and hand loads at levels that occur frequently in industrial work. High-precision spatial recordings were accomplished with a three-dimesional motion-analysis system, and the IMP was measured using the microcapillary infusion technique. The mean IMP of the infraspinatus muscle as well as that of the supraspinatus muscle increased continuously from a resting pressure at 0° of upper arm elevation to a maximal pressure at 90° of upper arm elevation, for all elevation planes. The mean IMP of the supraspinatus muscle appeared to be more dependent upon the elevation plane and less dependent upon the hand load, compared to the infraspinatus muscle. Even during only moderate arm elevation, the mean IMP of the infra- and supraspinatus muscles, presented here in polar diagrams, had already exceeded the levels of reduced recovery from local muscle fatigue and blood flow impairment. The elevation angle and the hand load primarily influence the development of IMP in the infra- and supraspinatus muscles.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1439-6327
    Keywords: EMG ; Localized muscular fatigue ; Spectral changes ; Intramuscular pressure ; Ergonomics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The purpose of the present study was to investigate if the intramuscular pressure generated during an isometric muscle contraction is important for the appearance of EMG spectral changes accompanying localized muscular fatigue. The EMG and intramuscular pressure of the left biceps brachii in eight volunteers were recorded during standardized isometric contractions by means of intramuscular wire electrodes and infusion catheters, respectively. Spectral changes were elicited by a submaximal contraction and the intramuscular pressure at which the induced spectral changes were able to recover was determined. It was found that significant recovery was possible only if the intramuscular pressure dropped below a level of about 2.7 kPa (20 mm Hg). It is concluded that the intramuscular pressure during a sustained isometric contraction is relevant for the generation of fatigue induced spectral changes, and that measurement of the intramuscular pressure makes possible predetermination of whether or not an isometric muscle contraction is liable to result in localized muscular fatigue.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1439-6327
    Keywords: Cardiac performance ; Circadian rhythm ; Shift work
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Circadian variations of the pre-ejection period, Q-T interval, heart rate and oral temperature at rest and in day and night shift work were investigated. At rest, pronounced circadian variation was found in heart rate, pre-ejection period and Q-T interval. The ratio between Q-T interval and heart rate also shows a distinct circadian variation. When working, the rest rhythms of the variables were obscured. The physiological implications for shift work are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0736-0266
    Keywords: Intramuscular pressure ; EMG ; Muscle force ; Biomechanic models ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: The force output of the biceps brachii muscle during static isometric contractions was studied in 26 arms of 23 subjects in relation to the simultaneously recorded level of the electromyogram (EMG) and the intramuscular pressure (IMP). The EMG was picked up with wire electrodes and the IMP recorded through wick catheters or by infusion technique. The load at the wrist was monitored using a force transducer. A near linear relationship with correlation coefficients exceeding 0.96 was shown between the load on the wrist on the one hand and IMP and EMG on the other. The regression coefficients of the relation between the load and IMP or EMG varied considerably between individuals and between different measuring points in the same individual. In cases where the correlation between the wrist load on one hand and the IMP and EMG on the other was poor because of varying synergistic interaction between the flexor muscles, the EMG and IMP were always well correlated. This means that they change in the same way when the mechanical output of the muscle varies. This was also the case in three experiments where the IMP and EMG from all three elbow flexors were recorded while the subjects changed from a supinated to a pronated position supporting a constant load on the wrist. Considering these observations we present indirect evidence that IMP and the level of the EMG signal both are good estimators of isolated muscular force under isometric static conditions and over limited time.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...