Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0509
    Keywords: Liver, neoplasms ; Sonography ; Angiography ; Computed tomography ; Oily contrast media
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract To evaluate the characteristics of combined hepatocellular and cholangiocarcinoma of the liver by imaging techniques, six patients (five male and one female), aged 46–60 years, with proved combined tumors were selected for this study from the review of 500 resected specimens of liver tumors. Images obtained from sonography, computed tomography (CT), angiography, and CT after intraarterial injection of iodized oil (iodized-oil CT) were retrospectively reviewed and correlated with the appearance of pathologic specimens. Sonographic findings were round or ovoid hypoechoic masses with central hyperechoic area (target appearance) in all patients. On CT scans, tumors were relatively well-defined low- and/or iso-attenuation masses in all patients. Angiography showed hypovascular masses in five patients. In one patient, the tumor appeared as a hypovascular mass with a central hypervascular area. On iodized-oil CT scans, all patients showed partial retention of iodized oil in tumors. Echogenicity in tumors at sonography or attenuation in tumors at CT could not be correlated with histologic difference in tumors at pathologic specimens. However, the hypervascular area at angiography and the compact retention areas of iodized oil at iodized-oil CT corresponded to portions of hepatocellular carcinoma within the combined tumor. On the basis of our results, imaging features, including target appearance at sonography, hypovascular mass with central hypervascular portions at angiography, and partial retention of iodized oil in tumors at iodized-oil CT, might be helpful in making accurate diagnosis of these rare tumors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 70 (1999), S. 3774-3775 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We demonstrate a simple calibration method of a rf magnetic probe by utilizing a two port network analysis method. The sensitivity (V/G) of the probe is determined by measuring the scattering parameters of S11 and S21. The magnetic field generated by the Helmholtz coil is calculated from S11 and the probe sensitivity is obtained from S21. The measured probe sensitivity is 0.1–0.6 V/G in the frequency range of 1–15 MHz. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 70 (1999), S. 2516-2519 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A frequency modulated interferometer is developed, which uses a 94 GHz Gunn oscillator and a single sideband (SSB) upconverter as a frequency modulator. An SSB upconverter makes it possible to use a heterodyne phase measurement technique with one mm-wave source. In addition, the influence of frequency drift and phase noise of a mm-wave source on the phase measurement can be reduced. In this work, the performance of a SSB upconverter as a frequency modulator is examined. Also, overall performance of the mm-wave interferometer with a SSB upconverter and line density measurement results in a mirror device are described. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 70 (1999), S. 1397-1401 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The Korea Superconducting Tokamak Advanced Research (KSTAR) project is the Korean national fusion program for constructing a superconducting tokamak, that is capable of a steady-state operation. Currently, the KSTAR diagnostic group is concentrating on conceptual design activities to provide measurements of the plasma behavior that is necessary to satisfy the KSTAR missions. A diagnostic overview for the KSTAR device is presented. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 97 (1992), S. 2742-2749 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: Reactions of N+ and N+2 ions with Si(100) surface are examined as a function of both ion kinetic energy and dose using a low energy ion beam instrument. The Si surface is exposed to low energy (1–300 eV) ion beams in an ultrahigh vacuum environment and the resulting surface species are characterized by Auger electron spectroscopy and ultraviolet photoelectron spectroscopy. The absolute reaction probability Pr is measured for nitridation processes. Pr(N+) has a value of ∼0.25 and stays constant in the energy range of 1–25 eV. Pr(N+2) increases from zero to ∼0.25 in the same range. Continued exposure of the ion beams to a dose (approximately-greater-than)5×1015 ions/cm2 leads to a saturation and formation of a dense and stable silicon nitride layer. Variation of Pr with energy and dose is explained in terms of elementary reaction steps such as charge neutralization of the projectile ion, collisional dissociation of N+2, nitridation reaction, and chemically induced desorption of surface nitrogen species. A mechanism is proposed to explain enhancement in the stability and ordering of the nitride layer during the low energy ion–surface interaction. At saturation the processes of both nitridation and chemically induced desorption simultaneously occur, which, under hyperthermal environments, effectively remove defects and interstitial nitrogen atoms from the layer.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The characteristics of electron cyclotron resonance (ECR) plasmas at the plug chamber of the "Hanbit" plasma facility have been investigated. The chamber length and diameter are 2.25 m and 1.5 m, respectively, and three pairs of solenoids are used to produce a variety of magnetic field configurations. Two magnetrons of 5 kW maximum output power each are used to produce the ECR plasma, and the microwaves are launched in extraordinary mode (X-mode) and/or right-hand circular polarized mode (R-mode). The dependence of the radial plasma density profile and the energy distribution of end loss ions upon the magnetic field strength and geometry, gas pressure, microwave power, and the mode of microwave are investigated. The plasma parameters are measured by using a position-controllable electrostatic probe, an x-ray spectrometer, and a multigrid ion energy analyzer. Transitions, occurred by threshold magnetron powers between low and high density modes, are found on certain conditions of magnetic field geometry and gas pressure. The density profile and the ion energy distribution are strong functions of magnetic field geometry and gas pressure, respectively. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 72 (2001), S. 431-434 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The diamagnetic effect is measured by using the diamagnetic loop with a compensation loop in the central cell of the Hanbit magnetic mirror device. To ensure reliable measurement, the influence of nearby conductors on the diamagnetic loop signal is investigated, and the output voltages during a pulsed vacuum field are measured to calibrate the loops installed inside the central cell. The diamagnetic measurement is carried out during rf discharges with a frequency of 3.75 MHz and heating power of up to 150 kW. In the measurement, the vacuum field of 0.126 T is applied in the central cell. The results from the experimental measurements are presented. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A Thomson scattering system on the Hanbit magnetic mirror device has been installed to measure the electron temperature and density of the plasma in the central cell. The configuration is based on a standard 90° scattering scheme. The optical system consists of a Q-switched Nd:YAG laser, input optics, collection optics, spectrograph optics, detectors, and a data acquisition system. Although the laser beam path is about 50 m long and the background emissions are not low, the electron temperature measurements have been made at a single point on a shot-by-shot basis, in which the stray light was considerably suppressed by using a beam dump, a viewing dump, and baffles. The measured electron temperature is about 50–70 eV in experiments for plasma production and heating by ICRF of 200-kW-rf power using a slot antenna. A description of the installed system and the experimental results are presented. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 80 (2002), S. 479-481 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: White-colored materials synthesized by a thermal annealing of milled GaN powders at 930 °C in a nitrogen atmosphere were identified to be monoclinic β-Ga2O3 nanowires by x-ray diffraction and scanning electron microscopy. High-resolution transmission electron microscopy revealed that these nanowires are single nanocrystals, and energy dispersive x-ray indicated that these nanomaterials are free of any metals. In addition, bundles of these crystalline nanowires in the rectangular-pole shape are a few centimeters in length.© 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of muscle foods 6 (1995), S. 0 
    ISSN: 1745-4573
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: A total 264 pork loins were selected to represent a wide range of pork quality of the longissimus thoracis et lumborum. CIE L*C*h color space showed a closer relationship to the subjective color score than L*a*b*color space. Lightness (L*) was the best measure to predict water-holding capacity (WHC). There were highly significant (p 〈 0.001) correlations between the measures of color and WHC, and curvilinear relationships between either WHC and color or pHu were observed. In normal muscle color range (reddish-pink), there was considerable variation in WHC. Within the RSE + RFN groups of muscles, less variation of WHC could be accounted for by variations in color measurements. Color and WHC were not closely related and suggest that the RSE (reddish-pink, soft, exudative) condition should be classified as a separate quality category of pork muscle.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...