Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 116 (1994), S. 7341-7348 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Chemical Physics 189 (1994), S. 53-65 
    ISSN: 0301-0104
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 325 (1969), S. 952-954 
    ISSN: 1435-2451
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Unter den 32 Patienten, die in der Zeit zwischen 1966 und 1968 mit manifester Tetanuserkrankung zur stationären Behandlung kamen, waren 21 weder aktiv noch passiv immunisiert worden. Die übrigen 11 hatten teils Tetanol, teils heterologes Serum oder eine Kombination beider erhalten. Nach der stationären Aufnahme wurden alle aktiv immunisiert und mit heterologem oder homologem Serum behandelt. Bestimmungen des neutralisierenden Antitoxintiters zeigten bei vergleichbarer Dosierung die Überlegenheit des humanen Hyperimmunglobulins. Aus immunologischen Überlegungen wird bei manifester Erkrankung die Gabe von homologem Serum empfohlen.
    Notes: Summary Amongst the 32 patients, who came to us for hospital treatment for manifest tetanus between 1966 and 1968, 21 were neither actively nor passively immunised. The remaining 11 had received either Tetanol or heterologous serum or a combination of the two. After admission to hospital, they were all actively immunised and treated with either heterologous or homologous serum. Determination of the neutralising antitoxin titres demonstrated the superiority of the human hyper-immunoglobulin using comparative dosage. As a result of immunological consideration, we would recommend administration of homologous serum in cases, where the disease is manifest.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary It is shown for some examples that the quantitative interpretation of depth profiles obtained by emission spectrometry with glow discharge excitation (GDOS) seems to be possible by comparative measurements with independent methods, by “extrapolation” of GDOS-results for the bulk, and by investigating commercial reference materials. A high reproducibility of the depth profile measurements was obtained by reducing some effects caused by the electrical power supply, uncontrolled sample temperature, and the influence of air. It could be shown by this method of depth profile analysis that it is possible to give quantitative details (in mg/m2) about the various alloying elements in different layers of the steel surface.
    Notes: Zusammenfassung An einigen Beispielen wird gezeigt, daß mit der Glimmlampenspektrometrie (GDOS) erhaltene Tiefenprofile durch Vergleichsmessungen mit anderen Verfahren (Ionenätzen; chemisches Lösen), durch „Extrapolation“ der an der Probenmatrix erhaltenen Ergebnisse und die Untersuchung von Referenzproben quantitativ interpretierbar sind. Eine hohe Reproduzierbarkeit der Tiefenprofilmessungen wurde durch eine Änderung der Regelkonstanten bei der elektrischen Versorgung der Anregungsquelle, eine Verminderung des Luftzutritts in den Kathodenraum und die Konstanthaltung der Probentemperatur erreicht. Es konnte gezeigt werden, daß diese Tiefenprofilmessungen Angaben über die in verschiedenen Tiefen vorliegenden Anteile der Legierungselemente und der Stahlbegleiter in mg/m2 erlauben.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 325 (1986), S. 88-94 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Doppel-Optik-Simultan-Spektrometrie (DOSS) verwendet für die Messung der Untergrundintensitäten ein zweites Spektrometer, das auf Positionen nahe neben den Analytlinien eingestellt ist. Für jeden Analytkanal steht ein eigener Untergrundkanal zur Verfügung. Man braucht deshalb weder eine Blindlösung noch angepaßte Standardproben. DOSS vereinigt somit die Vorteile des räumlichen Auflösungsvermögens der Photoschicht mit der Schnelligkeit und Rauscharmut eines Photomultipliers. Die simultane Erfassung beider Signale spart Zeit und Probemenge. Sie verbessert die Nachweisgrenze in Fällen, wo das Rauschen von Plasma oder Zerstäuber dominiert. Es ergeben sich keine Nachteile gegenüber anderen Simultanspektrometern. Für die Analyse linienreicher Matrices würde ein drittes Spektrometer mehr Freiheit für die Wahl der Untergrundpositionen ergeben.
    Notes: Summary In dual optic simultaneous spectrometry (DOSS) a separate spectrometer is used for the measurement of all background-near analyte lines. Neither a blank solution nor reference samples are necessary for the determination of the background. The simultaneous measurement of gross and background signals saves time and amount of sample. Detection limits are improved in cases of dominating plasma or nebulizer noise. There are no disadvantages of DOSS as compared with conventional simultaneous instruments, except that an additional calibration step is required to account for any difference in sensitivity within the pairs of channels. A third spectrometer would offer more freedom of choice for the optimal distance between analyte and background channels and would permit estimation of background under the analyte lines by interpolation between adjacent positions. Multi Optic Simltaneous Spectrometry combines the speed of simultaneous and the versatility of sequential instruments.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 326 (1987), S. 520-523 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Lösungsherstellung für die Stahlanalyse mit der ICP-Spectrometrie erfolgt durch Elektrolyse in HCl. Zahlreiche Elemente (wie Al, Si, Mn, Cr, Ni, Co) können in unlegierten und niedriglegierten Stahlproben mit C-Gehalten unter 0.3% bestimmt werden.
    Notes: Summary The preparation of solutions for steel analysis by ICP spectrometry is performed by electrolysis in HCl. Numerous elements (as Al, Si, Mn, Cr, Ni, Co) can be determined in unalloyed and low-alloy steel with C-contents of less than 0.3%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 351 (1995), S. 125-128 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The quantitative determination and the depth profile analysis of non-conductive materials by SNMS and GDOES is possible using a high-frequency sputtering technology for discharging. To improve the SNMS with HF sputtering technology for the analysis of environmentally relevant oxidic dusts, a certified standard ash is used. The quantitative evaluation has shown a markedly excessive concentration for the alkali elements. Another effect is the appearance of the mass m/e=20, which can be allocated to an Ar2+ ion. The influences of conductivity of the samples, HF frequency, rate of sputtertime and of the target voltage on these effects have been investigated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 199 (1964), S. 244-246 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A new polarographic cell is described, which is suitable for serial determinations. It has proved to be advantageous especially in the determination of lead, copper, and zinc in ores and similar matters.
    Notes: Zusammenfassung Es wird ein neues Elektrolysengefäß für polarographische Serienbestimmungen beschrieben, dessen Vorteile sich besonders bei der Bestimmung von Blei, Kupfer und Zink in Erzen und ähnlichen Stoffen erwiesen haben.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 319 (1984), S. 665-669 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Emissionsspektrometrie mit Grimmanregungsquelle (GDOS) liefert rationell und einfach zu interpretierende Tiefenprofile. Es können sowohl dünnste Schichten von 2 nm als auch aufgebrachte Metallbeläge bis zu 100 μm untersucht werden. Art und Verteilung der Elemente in den Schichten werden innerhalb weniger Minuten nachgewiesen und durch Vergleich mit Standardreferenzmaterialien quantifiziert. Damit stellt die Oberflächenanalytik mittels GDOS ein wichtiges, in vielen Anwendungsfällen unentbehrliches Hilfsmittel bei der Verfahrensentwicklung und Produktcharakterisierung metallischer Werkstoffe dar.
    Notes: Summary The glow discharge optical spectrometry (GDOS) produces depth profiles in a simple and economical way. Thinnest layers of about 2 nm as well as metal coatings up to 100 μm can be analysed. Type and distribution of the elements in coatings are identified and determined within a few minutes by comparing the signals obtained with those of standard reference samples. Hence, the GDOS-surface analysis method proves to be an important and in many cases an undispensable auxiliary means in connection with the improvement of production processes and the characterisation of the metallic products.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 249 (1970), S. 100-105 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die spektrometrische Analyse von weiß erstarrtem Roheisen (auf C, Si, Mn, P, S, Cu) ist mit der gleichen Anregung und in der gleichen Funkzeit wie diejenige von Stahl möglich. Eine spezielle Kalibriertechnik mit Stahlproben garantiert ein ausreichend reproduzierbares und richtiges Resultat in relativ kurzer Zeit (20 sec).
    Notes: Abstract The conditions of pig iron analysis by using a direct reading spectrometer for routine determination of C, Si, Mn, P, S and Cu, the influence of sampling and a new calibration technique of the instrument are described. The whole time needed for complete spectrometrical analysis is about 20 sec.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...