Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0173-0835
    Keywords: Micellar electrokinetic chromatography ; Bile salts ; Sodium cholate ; Polychlorinated biphenyls ; Enantiomeric separations ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Micellar electrokinetic chromatography (MEKC) with one kind of bile salt (sodium cholate) was used to separate three chiral polychlorinated biphenyls (PCBs; 84, 95, and 176), each one in its two enantiomers. Sodium cholate was used as chiral surfactant in a 2-(N-cyclohexylamino) ethanesulfonic acid (CHES) buffer under alkaline (pH 10) conditions containing urea (2 M). The influence of bile salt concentration on the efficiency and the resolution between the two enantiomers of PCBs 84 and 95 was established. The chiral separation of three PCBs was successfully achieved in less than 30 min (approximately 23 min for PCB 176 and approximately 29 min for PCBs 84 and 95).
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 373-378 
    ISSN: 0935-6304
    Keywords: Open tubular columns ; capillary electrochromatography ; column efficiency ; injected volume ; applied voltage ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The effect of some instrumental parameters on column efficiency in open tubular capillary electrochromatography (OTCEC) has been evaluated. First, it was investigated whether band broadening due to the sample injection process is within a tolerable range when an open tubular column (OTC) of about 10 μm i. d. is used. As a result of the small injection profile factor (K2 = 1.3), injected volumes must be sufficiently small (less than 10 pL) to avoid a significant efficiency loss (〉5%) when hydrodynamic injection by siphoning is employed. Secondly, the kinetic performance of OTCs in a CEC system was estimated from the variation of the reduced plate height (h) with the reduced linear velocity (ν) which was controlled by the voltage applied. Reasonable agreement was obtained between the theoretical h versus ν curve and the experimental values for a group of polycyclic aromatic hydrocarbons used as test compounds. Values of 0.25 for minimum h at an optimum ν of 16 are estimated, which permit separations with around 400,000 plates per meter to be obtained in less than 5 min. Finally, the possibility of estimating the diffusion coefficients of the solutes in the mobile phase from the plot of the height of a theoretical plate versus electroosmotic flow velocity is shown.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...