Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Chirality 2 (1990), S. 208-210 
    ISSN: 0899-0042
    Keywords: enantioselectivity ; three-point model ; didactic model ; chiral separations ; ligand-exchange chromatography ; Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: If diastereomeric complexes are adsorbed on a surface or if they include a molecule of solvent, two points of attractive interaction between the chiral species of the complex can be sufficient for mutual chiral recognition of these species. In special cases even one single point of interaction is sufficient. This extension of the three-point contact rule of Dalgliesh, first observed in chiral ligand-exchange chromatogrphy, can be demonstrated by using hands.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Chirality 3 (1991), S. 471-475 
    ISSN: 0899-0042
    Keywords: amino acids ; kinetics ; epimers ; OPA ; postcolumn reaction detection ; fluorescence detection ; amino acid racemization ; dating methods ; Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The kinetics of the reaction of the amino acid epimers L-isoleucine, D-alloisoleucine, L-threonine, and D-allo-threonine with o-phthaldialdehyde and mercaptoethanol were determined at 25°C. L-Isoleucine reacts faster than its D-epimer whereas L-threonine reacts slightly slower than its D-epimer. In the case of isoleucine, the consequence can be an allo/iso ratio which in the worst case is 25% too low if these amino acids are quantified by liquid chromatography and o-phthaldialdehyde fluorescence detection. The effect on dating of fossils by amino acid racemization is discussed.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Chirality 7 (1995), S. 567-571 
    ISSN: 0899-0042
    Keywords: enantiomer separation ; chromatographic resolution ; peak integration ; peak size ratio ; calibration curve ; determination of optical purity ; Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The chromatographic quantitation of very low amounts of an enantiomer in the presence of its antipode can be an extraordinary challenge. If resolution of the peaks is not complete even at extreme mass ratios an integrator will yield inaccurate results due to geometric effects. A given resolution can be adequate for peaks of similar size but result in severe overlap if one of the signals is markedly smaller. If tailing occurs, which is more the rule than the exception, the problem is especially severe for last eluted small peaks. Additional obstacles are detector nonlinearity and other sources of unsatisfactory calibration curves, overloading phenomena, and the possible lack of standards of highest optical purity. These problems have been studied by computer simulations and the liquid chromatographic separation of (R,S)-phenylethyl naphthoic acid amide on a chiral stationary phase. © 1995 Wiley-Liss, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Chirality 1 (1989), S. 167-169 
    ISSN: 0899-0042
    Keywords: enantioselectivity ; three-point model ; chiral receptors ; chiral separations ; didactic model ; elusion of the three-point model ; Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Hands can be used to demonstrate the three-point model of chiral recognition. The points of attachment are thumb, forefinger, and middle finger. This vivid model has the advantages of simplicity, perspicuity, and availability at any time, although two persons are necessary. It can be shown that two interactions are not sufficient for chiral recognition but that three attractive or two attractive and one repulsive attraction are needed. It can also be used to explain some possibilities of weakening or elusion of the three-point model.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 28 (1989), S. 420-421 
    ISSN: 1612-1112
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...