Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0021-9673
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 12 (1998), S. 1294-1296 
    ISSN: 1432-2218
    Keywords: Key words: Laparoscopic surgery — Port site metastasis — Abdominal cancer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: Port site metastasis following laparoscopy for cancer is reported with increasing frequency and represents one of the most important limitations of the technique. Methods: A scintigraphic model was utilized to evaluate a possible role of pneumoperitoneum in tumor cell dissemination. Labeled red blood cells (RBC) were injected at the level of the gallbladder bed during laparoscopic cholecystectomy (LC) performed for symptomatic cholecystolithiasis. LC was performed in two groups with standard CO2 pneumoperitoneum: in one group an endobag for retrieval of the specimen was utilized. In one group a gasless LC with endobag was performed. Results: Radioactivity in the area of the trocar introduction was observed in almost all the patients who underwent standard (CO2) LC but represented a rare event in patients treated with the gasless method. The utilization of a protective bag for the extraction of the surgical specimen did not modify significantly the results. Moreover all patients treated with pneumoperitoneum demonstrated a wide intraperitoneal diffusion of the tracer not observed in gasless patients. Conclusions: The results of this study confirm that pneumoperitoneum may play an important role in the evolution of port site metastasis after laparoscopy for gastrointestinal cancer.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1573-0743
    Keywords: dobutamine stress echocardiography ; myocardial scintigraphy ; SPET ; Sestamibi ; pharmacological stress testing ; coronary artery disease
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: Simultaneous dobutamine stress echocardiography (DSE) and99mTc-MIBI-SPET (DMS) for the evaluation of the presence and the extent of coronary artery disease (CAD) were assessed for a head to head comparison regarding the diagnostic accuracy of the two tests. Methods and Results: Forty-five consecutive patients (33 males and 12 females: 53±6.8 yr.) underwent exercise electrocardiography and simultaneous dobutamine stress echocardiography and MIBI-SPET imaging. Coronary angiography was performed in all patients (significant coronary stenosis 〉 50%). On the basis of the results of exercise electrocardiogram the pre-test probability for coronary artery disease (Diamond's algorithm) was low (45.6±12.7 %). The overall specificity, sensitivity and predictive accuracy of Echo-dobutamine stress test for diagnosis of the presence or absence of CAD were: specificity 82%, sensitivity 76%, diagnostic accuracy 80%, positive predictive value 90%, negative predictive value 40%. The overall specificity, sensitivity and predictive accuracy of MIBI-SPET-dobutamine test for diagnosis of the presence or absence of CAD were: specificity 86%, sensitivity 87%, diagnostic accuracy 84%, positive predictive value 97%, negative predictive value 54%. MIBI-SPET-dobutamine test showed a significantly higher sensitivity in comparison with ECHO-dobutamine test (P〈0.05). Conclusion: Both noninvasive methods for the detection of CAD showed a good diagnostic accuracy. Nevertheless the SPET model showed an higher sensitivity in comparison with DSE model, essentially in the presence of a lower extent of CAD and during submaximal test.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...