Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Experimental brain research 112 (1996), S. 112-118 
    ISSN: 1432-1106
    Keywords: Monosynaptic reflex ; H-reflex variability ; Fractal ; Supraspinal ; Spinal cord injury ; Human
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In our previous study, $${1 \mathord{\left/ {\vphantom {1 {f^\beta }}} \right. \kern-\nulldelimiterspace} {f^\beta }}$$ -type power spectrum with the spectral exponent β significantly greater than zero was found in the variability of soleus H-reflex amplitudes. This result indicated that the H-reflex variability was time-correlated owing to fractal characteristics. Furthermore, it was also suggested that the fractal characteristics were generated at the spinal level. The purpose of the present study was to investigate whether the fractal nature of the H-reflex variability was influenced by the loss of supraspinal input. Six healthy normal subjects and seven patients with spinal cord injury participated in this study. Soleus H-reflexes were evoked every l s from both legs simultaneously (stimulation intensity: motor threshold) and 1050 successive amplitudes of the H-reflex were recorded. The H-reflex sequence evoked from each leg was analyzed by “coarse graining spectral analysis” to calculate the spectral exponent β. The value of β was used to evaluate the level of time-correlation (fractal correlation). Cross-spectral analysis was used to evaluate the degree of synchronization between the H-reflex sequences evoked from both legs. The β values for normal subjects (0.84±0.33, left leg; 0.88±0.34, right leg) were significantly greater (P〈0.001) than those for patients (0.31±0.18, left leg; 0.32±0.14, right leg), suggesting that the H-reflex sequences for normal subjects were more time-correlated than for patients. In the frequency range less than 0.2 Hz, the coherence of both legs was high (0.41±0.14) for normal subjects as compared to 0.20±0.12 for patients (P〈0.005). In this frequency range, the phase was almost 0 rad for normal subjects, indicating that the H-reflex variabilities of both legs were synchronized. These results suggested that (1) the strong fractal correlation observed in the H-reflex sequences for normal subjects was associated with supraspinal input, and (2) such supraspinal input had equal influence on the reflex arcs of the soleus of both legs.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 77 (2000), S. 588-590 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The emission property of a Spindt-type platinum field emitter was greatly improved by operating in carbon monoxide ambient with appropriate operating parameters. After sufficient aging, the emitter was operated in carbon monoxide ambient up to 10−3 Pa, at the emission current of 1 μA. The emission current first decreased in accordance with the gas introduction, but turned to show rapid increase when the gas pressure was increased to 10−3 Pa. The current stability, as well as the operating voltage, was improved by this treatment. The apex of the emitter was examined with the Seppen–Katamuki analysis technique, in which detailed information on the emission area and effective work function can be read from the diagram plotted with the intercept and slope of a Fowler–Nordheim plot. The analysis suggested reduction of the effective work function is a major reason for the improvement of the emission property. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Scandinavian journal of medicine & science in sports 3 (1993), S. 0 
    ISSN: 1600-0838
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine , Sports Science
    Notes: To determine the mechanical of rowing, oxygen uptake and mechanical work rate were measured during rowing a single scull under windless conditions. Steady-state pulmonary oxygen uptake was determined as a function of boat velocity (v (m-s−1)) in 5 subjects. Oxygen uptake (1-min−1) increased as 0.065 v2.99. Workrate in two subjects was determined as a function of v by measuring the force applied to the oar and its angular velocity. Work rate (w) was expressed as 3.85 v3.25. From these equations, mechanical efficiency (%) was expressed as 17 v0.262. Thus, mechanical efficiency increased from 20% at 2 m-s−1 to 24% at a boat velocity of 4 m-s−1.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...