Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1434-3940
    Keywords: Schlüsselwörter Orbitarekonstruktion ; Resorbierbare Implantate ; Polylaktat ; Key words Orbital reconstruction ; Biodegradable implants ; Polylactide
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary In a complex animal model in sheep, polydioxanone (PDS®) and polylactic membranes were used for the reconstruction of large orbital-wall defects. In a long-term experiment over 1 year, polylactic implants alone showed the best performance as compared with combinations involving autogenous bone grafts and titanium miniplate fixation. As soon as these polylactic implants are approved for human surgery, they will be used to solve the still challenging problem of anatomical reconstruction of large comminuted fractures of more than one orbital wall.
    Notes: Zusammenfassung In einem experimentellen Modell wurden biodegradierbare Membranen aus Polydioxanon (PDS ® ) resp. Polylaktat zur Rekonstruktion großer Orbitawanddefekte bei Schafen verwendet. Im Langzeitversuch über ein Jahr zeigten diejenigen Rekonstruktionen die besten Resultate, bei welchen ausschließlich biodegradierbare Implantate aus Polylaktat zur Anwendung kamen. Bei gleichzeitiger Verwendung von autologen Knochentransplantaten und Titan-Miniplatten-Osteosynthesen war die anatomische Form der rekonstruierten Orbita weniger zuverlässig gewährleistet. Es darf erwartet werden, dass die klinische Zulassung der Polylaktat-Implantate die chirurgische Wiederherstellung ausgedehnter Trümmerfrakturen mehrerer Orbitawände wesentlich erleichtern wird und zu vorhersehbaren, anatomischen Rekonstruktionen führt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Archives of orthopaedic and trauma surgery 119 (1999), S. 82-85 
    ISSN: 1434-3916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Resistance to local infection after fracture fixation with plate osteosynthesis may be influenced by the implantation technique. It is known that the extent of the surgical approach to the bone can compromise the local defence capacity. We have investigated susceptibility to infection after a local bacterial challenge in rabbit tibiae using either the open surgical approach for ‘biological’ internal fixation of standard 2.0 dynamic compression plates or the method of minimally invasive plate osteosynthesis (MIPO), a percutaneous, tunnelling insertion technique preserving the integrity of the overlying soft tissue. After the wounds had been closed, various concentrations of Staphylococcus aureus were injected in the direct vicinity of the implants. The infection rate for the open surgical technique was 38.5% and that for the MIPO technique, 25%. This difference is not statistically significant (P 〉 0.05) suggesting that resistance to local infection associated with the MIPO method is at least equivalent to the open approach for plate osteosynthesis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-2277
    Keywords: Key words Troponin-T ; Cardiac rejection ; Heart transplantation ; Cardiac enzymes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Non-invasive detection of cardiac rejection still remains a challenge after heart transplantation. We assessed troponin-T as a new serum marker to diagnose cardiac rejection. Twenty-five heart transplant patients (Berne) were monitored prospectively for up to 2 years, and compared to 89 retrospectively assessed patients (Stanford). Blood samples (392 Berne and 320 Stanford) were analyzed (creatine kinase, isoenzymes MB activity and MB mass, troponin-T and troponin-I). Regression analysis between the results of these blood samples and cardiac rejection grading from simultaneously performed endomyocardial biopsies was carried out. Troponin-T tests done in two different laboratories showed a good correlation (r = 0.91; P 〈 0.0001), whereas tropinin-T versus troponin-I showed a lower correlation (r = 0.53; P 〈 0.0001). Troponin-T and -I in contrast to other enzymes were elevated for a longer period (up to 4 weeks before returning to baseline) after transplantation than during conventional cardiac surgery. Beyond 3 months the following correlations were found between troponin-T (new or old test) and the other enzymes (creatine kinase: r = 0.26, MB activity: r = 0.4, and MB mass: r = 0.68). The correlation between the degree of rejection and the enzyme release is poor, however, the best results were obtained for troponin-T (r = 0.22; P 〈 0.001). We found a low correlation between troponin-T and the degree of rejection beyond 3 months after heart transplantation. Despite a troponin-T elevation in some patients with rejection, the new test is not sensitive enough to be used alone for the non-invasive diagnosis of cardiac rejection.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...