Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1573-675X
    Keywords: Apoptosis ; CD95 (Fas/APO-1) ; NF-κB/Rel ; T lymphocytes.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract The activity of NF-κB/Rel transcription factors can inhibit the apoptosis induced by TNF, UV or cancer therapy drugs in a number of cell types, including human T lymphocytes. Furthermore, the NF-κB/Rel inducer, phorbol-12-myristate-13-acetate (PMA), has been reported to suppress the CD95-induced apoptosis of human T lymphocytes. To verify whether the survival-enhancing effect of PMA required NF-κB/Rel activity, we generated two Jurkat cell sublines (AL.7 and AL.8) transfected with a pCMV4-IκBα construct, and two (AL.3 and AL.5) with the void pCMV4 vector. Compared to wild type, AL.3 and AL.5 cells, the AL.7 and AL.8 sublines displayed markedly lower amounts of NF-κB/Rel nuclear complexes and a reduced expression of a κB-controlled CAT reporter gene after 1 and 4 h of incubation with PMA, respectively. All the five cell types displayed negligible levels of apoptosis when cultured with medium or PMA alone; when stimulated with the mAb CH-11, the AL.7 and AL.8 sublines displayed apoptotic responses only slightly (〈0.5 fold) higher than control cells. On the other hand, the salvage activity of PMA was partially impaired in the AL.7 and AL.8 sublines. PMA inhibited apoptosis by 〉85% in wild type, AL.3 and AL.5 cells and by 〈60% in the AL.7 and AL.8 sublines; the apoptosis percentages in the mAb CH-11 + PMA cultures of the IκBα-transfected cells were 〉4-fold higher than in control cells. We conclude that the inhibition of the CD95-induced apoptosis by PMA relies on both NF-κB/Rel-dependent and -independent mechanisms. The partial contribution of these nuclear factors to the suppression of apoptosis indicates that the NF-κB/Rel activity can influence the extent of the CD95-induced T cell death.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-0743
    Keywords: dobutamine stress echocardiography ; myocardial scintigraphy ; SPET ; Sestamibi ; pharmacological stress testing ; coronary artery disease
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: Simultaneous dobutamine stress echocardiography (DSE) and99mTc-MIBI-SPET (DMS) for the evaluation of the presence and the extent of coronary artery disease (CAD) were assessed for a head to head comparison regarding the diagnostic accuracy of the two tests. Methods and Results: Forty-five consecutive patients (33 males and 12 females: 53±6.8 yr.) underwent exercise electrocardiography and simultaneous dobutamine stress echocardiography and MIBI-SPET imaging. Coronary angiography was performed in all patients (significant coronary stenosis 〉 50%). On the basis of the results of exercise electrocardiogram the pre-test probability for coronary artery disease (Diamond's algorithm) was low (45.6±12.7 %). The overall specificity, sensitivity and predictive accuracy of Echo-dobutamine stress test for diagnosis of the presence or absence of CAD were: specificity 82%, sensitivity 76%, diagnostic accuracy 80%, positive predictive value 90%, negative predictive value 40%. The overall specificity, sensitivity and predictive accuracy of MIBI-SPET-dobutamine test for diagnosis of the presence or absence of CAD were: specificity 86%, sensitivity 87%, diagnostic accuracy 84%, positive predictive value 97%, negative predictive value 54%. MIBI-SPET-dobutamine test showed a significantly higher sensitivity in comparison with ECHO-dobutamine test (P〈0.05). Conclusion: Both noninvasive methods for the detection of CAD showed a good diagnostic accuracy. Nevertheless the SPET model showed an higher sensitivity in comparison with DSE model, essentially in the presence of a lower extent of CAD and during submaximal test.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...