Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 14 (2003), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Introduction: A rapidly firing or triggered ectopic focus located within a pulmonary vein (PV) or close to the PV ostium could induce atrial fibrillation (AF). The aim of this study was to evaluate the efficacy and safety of a radiofrequency thermal balloon catheter for isolation of the PV from the left atrium (LA). Methods and Results: Twenty patients with drug-resistant paroxysmal AF were treated by isolating the superior PVs using an RF thermal balloon catheter. Using a transseptal approach, the balloon, which had an inflated diameter 5 to 10 mm larger than that of the PV ostium, was wedged at the LA-PV junction. It was heated by a very-high-frequency current (13.56 MHZ) applied to the coil electrode inside the balloon for 2 to 3 minutes, and the procedure was repeated up to four times. The balloon center temperature was maintained at 60° to 75°C by regulating generator output. Successful PV isolation was achieved in 19 of the 20 left superior PVs and in all 20 of the right superior PVs and was associated with a decrease in amplitude of the ostial potentials. Total procedure time was 1.8 ± 0.5 hours, which included 22 ± 7 minutes of fluoroscopy time. After a follow-up period of 8.1 ± 0.8 months, 17 patients were free from AF, with 10 not taking any antiarrhythmic drugs and 7 taking the same antiarrhythmic agent as before ablation. Electron beam computed tomography revealed no complications, such as PV stenosis at ablation sites. Conclusion: The PV and its ostial region can be safely and quickly isolated from the LA by circumferential ablation around the PV ostia using a radiofrequency thermal balloon catheter for treatment of AF. (J Cardiovasc Electrophysiol, Vol. 14, pp. 609-615, June 2003)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Slow A V nodal pathway ablation using RF is highly effective for patients with refractory A V nodal reentrant tachycardia (AVNRT). We report three catheter ablation cases using RF current in patients associated with persistent left superior vena cava (PLSVC). Three patients with drug refractory AVNHT of common variety were involved in this study. An electrode catheter introduced through the left subclavian vein inserted directly into the coronary sinus, a typical anatomical finding of PLSVC. The ablation procedure was initially performed at the posteroinferior region of Koch's triangle. A slow pathway potential could not be found from that area; nonsustained junctional tachycardia (NSJT) did not occur during the delivery of RF current; there was failure to eliminate slow AV nodal pathway conduction. The catheter then was moved into the bed of the proximal portion of the markedly enlarged coronary sinus. A slow AV nodal pathway potential was recorded through the ablation catheter, and the delivery of RF current caused NSJT in two patients. Complete elimination of slow AV nodal pathway conduction was accomplished in these two patients by this method. No adverse effects were provoked by this procedure. Catheter ablation of the slow A V nodal pathway guided by a slow pathway potential and the appearance of NSJT was feasible and safe in the area of the coronary sinus ostium in patients associated with PLSVC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...