Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1520-5827
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The journal of membrane biology 93 (1986), S. 43-53 
    ISSN: 1432-1424
    Keywords: electropermeation ; electrofusion ; freeze-fracture ; intramembranous particles
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Summary The sequence of events during the electrically induced fusion of human erythrocytes was studied by rapid quench freeze-fracture electron microscopy. A single electric field pulse was used to induce fusion of human erythrocytes treated with pronase and closely positioned by dielectrophoresis. The electronic circuit was coupled to a rapid freezing mechanism so that ultrastructural changes of the membrane could be preserved at given time points. Pronase treatment enabled adjacent cells to approach each other within 15 nm during dielectrophoresis. The pulse caused a brief disruption of the aqueous boundaries which separated the cells. Within 100 msec following pulse application, the fracture faces exhibited discontinuous areas which were predominantly free of intramembranous particles. At 2 sec after the pulse, transient point defects attributed to intercellular contact appeared in the same membrane areas and replaced the discontinuous areas as the predominant membrane perturbation. At 10 sec after the pulse, the majority of the discontinuous areas and point defects disappeared as the intercellular distance returned to approximately 15 to 25 nm, except at sites of cytoplasmic bridge formation. Intramembranous particle clearing was observed at 60 sec following pulse application in discrete zones of membrane fusion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 27 (1999), S. 697-711 
    ISSN: 1573-9686
    Keywords: Antibody ; Environmental monitoring ; Functional assay ; Chemical warfare ; Extracellular potential ; Impedance ; Microelectrode ; Patterning ; Stem cells
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract Biosensors incorporate a biological sensing element that converts a change in an immediate environment to signals conducive for processing. Biosensors have been implemented for a number of applications ranging from environmental pollutant detection to defense monitoring. Biosensors have two intriguing characteristics: (1) they have a naturally evolved selectivity to biological or biologically active analytes; and (2) biosensors have the capacity to respond to analytes in a physiologically relevant manner. In this paper, molecular biosensors, based on antibodies, enzymes, ion channels, or nucleic acids, are briefly reviewed. Moreover, cell-based biosensors are reviewed and discussed. Cell-based biosensors have been implemented using microorganisms, particularly for environmental monitoring of pollutants. Biosensors incorporating mammalian cells have a distinct advantage of responding in a manner that can offer insight into the physiological effect of an analyte. Several approaches for transduction of cellular signals are discussed; these approaches include measures of cell metabolism, impedance, intracellular potentials, and extracellular potentials. Among these approaches, networks of excitable cells cultured on microelectrode arrays are uniquely poised to provide rapid, functional classification of an analyte and ultimately constitute a potentially effective cell-based biosensor technology. Three challenges that constitute barriers to increased cell-based biosensor applications are presented: analytical methods, reproducibility, and cell sources. Possible future solutions to these challenges are discussed. © 1999 Biomedical Engineering Society. PAC99: 8780-y, 0130Rr, 8717-d
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...