  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 70 (1999), S. 3329-3331 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Metal plasma formed by a vacuum arc plasma source can be passed through a toroidal-section magnetic duct for the filtering of macroparticles from the plasma stream. In order to maximize the plasma transport efficiency of the filter the duct wall should be biased, typically to a positive voltage of about 10–20 V. In some cases it is not convenient to bias the duct, for example if the duct wall is part of the grounded vacuum system. However, a positively biased electrode inserted into the duct along its outer major circumference can serve a similar purpose. In this article, we describe our results confirming and quantifying this effect. We also show the parametric dependence of the duct transport on the experimental variables. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 73 (1993), S. 4176-4180 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Ion species and their ratios in nitrogen, oxygen, and argon plasmas in the plasma source ion implantation process have been determined with a simple and low-cost measurement system. The measured ion species ratio in the nitrogen plasma was used as an input parameter for the computer simulation code transport and mixing from ion irradiation to predict the atomic composition-depth profile. Comparison between the code results and data derived from Auger analysis for a nitrogen-implanted Ti-6Al-4V alloy showed good agreement. In this article, the design, performance, and possible future improvements regarding the resolution of this measurement system will be discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 84 (1998), S. 1859-1862 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The absence of the line-of-sight restriction makes plasma immersion ion implantation an excellent interior surface treatment technique. In our experiments, we implanted both the outside and inside surfaces of a set of hollow cylindrical samples with and without a grounded conductive electrode positioned along the center of the bores to evaluate the impact energy as well as dose uniformity along the specimens. Our experimental results show that the use of the coaxial electrode increases the impact energy by 43% and retained dose by 71%. The nonuniformity is 20% to 30% and is worse with larger bore length. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Physics of Plasmas 4 (1997), S. 4431-4434 
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The temporal evolution of the plasma sheath in a small cylindrical bore with an auxiliary electrode is calculated for zero-rise-time voltage pulses. The ion density, flux, dose, ion energy distribu-tion, and electric field are determined by solving Poisson's equation and the equations of ion motion and continuity using finite difference methods. Our results indicate that the implantation time is about halved and slightly more than 50% of the ions possess impact energy higher than the maximum achieved when an auxiliary electrode is absent. The resulting ion flux, ion current, as well as ion energy distribution, are also determined. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 1495-1498 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The high voltage and electromagnetic field environment poses a big challenge to a control system for plasma immersion ion implantation (PIII). The automation process must be immune to electric field interference produced by the high voltage power supply, modulator, radio-frequency or microwave plasma generator, MEVVA plasma sources, and so on. We have recently designed and installed a distributed control system, PIIIDCS, to automate the operation of our PIII facility. Programmable logic controllers are used as the field control stations because of their good anti-interference ability and good real time response. A DH-485 network is used as the communication link between the field controllers and the management station in order to improve the robustness and reliability of the system. The newly developed interface is designed to work in a graphic mode in Microsoft Windows 95. Test runs have shown that the system is reliable, flexible, and easy to operate. The development of this novel control system will expedite the development of commercial PIII instrumentation. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 1866-1874 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A new generation multipurpose plasma immersion ion implanter (PIII) was custom designed, constructed, and installed in the City University of Hong Kong. The system is designed for general R&D applications in metallurgy, tribology, surface modification, and fabrication of novel materials. Using the new rf ion source in conjunction with the internal antenna system, the plasma density achieves excellent uniformity both laterally and axially. The system also incorporates two metal sources, including four metal arc sources and a sputtering electrode, so that multiple metal deposition and implantation steps can be performed in succession in the same equipment without exposing the samples to air. This capability can be critical to the study of surface properties and corrosion resistance. This article describes the design objectives, the novel features, and the characteristics of this new generation PIII equipment. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 70 (1999), S. 4359-4361 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: High energy implantation of metal ions can be carried out using conventional ion implantation with a mass-selected ion beam in scanned-spot mode by employing a broad-beam approach such as with a vacuum arc ion source, or by utilizing plasma immersion ion implantation with a metal plasma. For many high dose applications, the use of plasma immersion techniques offers a high-rate process, but the formation of a surface film along with the subsurface implanted layer is sometimes a severe or even fatal detriment. We describe here an operating mode of the metal plasma immersion approach by which pure implantation can be obtained. We have demonstrated the technique by carrying out Ti and Ta implantations at energies of about 80 and 120 keV for Ti and Ta, respectively, and doses on the order of 1×1017 ions/cm2. Our experiments show that virtually pure implantation without simultaneous surface deposition can be accomplished. Using proper synchronization of the metal arc and sample voltage pulse, the applied dose that deposits as a film versus the part that is energetically implanted (the deposition-to-implantation ratio) can be precisely controlled.© 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 86 (1999), S. 120-123 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Plasma immersion ion implantation (PIII) is an effective technique for the surface modification of industrial components possessing an irregular shape. We have recently used PIII to treat a real industrial ball bearing to enhance the surface properties of the race surface on which the balls roll. The implantation dose uniformity along the groove is assessed using theoretical simulation and experiments. The two sets of results agree very well, showing larger doses near the center. However, the highest dose is not observed at the bottom or center of the groove, but rather offset toward the side close to the sample platen when the bearing is placed horizontally. The minimum dose is observed near the edge or corner of the groove and our model indicates that it is due to the more glancing ion incidence as a result of the evolution of the ion sheath near the corner. The dose nonuniformity along the groove surface is about 40% based on our experimental data. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 83 (1998), S. 44-49 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A model utilizing cold, unmagnetized, and collisionless fluid ions as well as Boltzmann electrons is used to comprehensively investigate the sheath expansion into a translationally invariant large bore in the presence of an auxiliary electrode during plasma immersion ion implantation (PIII) of a cylindrical bore sample. The governing equation of ion continuity, ion motion, and Poisson's equation are solved by using a numerical finite difference method for different cylindrical bore radii, auxiliary electrode radii, and voltage rise times. The ion density and ion impact energy at the cylindrical inner surface, as well as the ion energy distribution, maximum ion impact energy, and average ion impact energy for the various cases are obtained. Our results show a dramatic improvement in the impact energy when an auxiliary electrode is used and the recommended normalized auxiliary electrode radius is in the range of 0.1–0.3. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 71 (1997), S. 1035-1037 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The temporal evolution of the plasma sheath in a small cylindrical bore in the presence of an auxiliary electrode is determined for different electrode radii. The ion density, velocity, flux, dose, ion energy distribution, and average impact energy are calculated by solving Poisson's Equation and the equations of ion motion and continuity using finite difference methods. The particle-in-cell method is also used to confirm the validity of the data. Our results indicate that more ions will attain high impact energy when the auxiliary electrode radius is increased, but the dose will decrease. Our results suggest that the normalized auxiliary electrode radius should range from 0.10 to 0.30 in order to maximize the dose and produce a larger number of ions with higher impact energy. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...