    Keywords: Anemia ; Preterm infants ; Serum lactate ; Cardiac output ; Oxygen saturation ; Blood transfusion ; Oxygen delivery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background Whether and when to transfuse in anemia of prematurity is highly controversial. Some authors suggest transfusions simply if the hemoglobin (Hb) level is below a defined normal range. Others propose the use of clinical or laboratory parameters in anemic patients to decide whether to transfuse or not. Hypothesis A decreasing amount of circulating Hb should cause a compensatory increase in cardiac output (CO) and an increase in arterial serum lactate. Materials and methods In 56 anemic preterm infants (not in respiratory or hemodynamic failure) we analyzed CO after the first week of life using a Doppler sonographic method. At the same time serum lactate levels. Hb levels and oxygen saturation were registered. Nineteen of these patients were given transfusion when they demonstrated clinical signs of anemia by tachycardia 〉180/min, tachypnea, retractions, apneas and centralization (group 2). The remaining 37 patients were not transfused (group 1). Serum lactate, CO, heart rate (HR), oxygen delivery, respiratory rate, capillary refill and Hb were analyzed in both groups and in group 2 before and 12–24 h after transfusion. Data between groups 1 and 2 and in group 2 before and after transfusion were compared. Results In the 56 patients studied no linear correlation between Hb and CO or between Hb and serum lactate was found. Nor could any correlation be demonstrated between the other variables studied Examining the subgroups separately a negative linear correlation was demonstrated between serum lactate and oxygen delivery in group 2. No other significant correlations were detected. However, when the pre- and post-transfusion data were compared in group 2 (increase of Hb from 9.45 (SD 3.44) to 12.5 (SD 3.8) g/100 ml), the CO decreased from 281. 3 (SD 162.6) to 224 (SD 95.7) ml/kg per min (p〈0.01) and serum lactate decreased significantly from 3.23 mmol/l (SD 2.07) before to 1.71 (SD 0.83) after transfusion. Oxygen delivery was 35.8 (±0.19) ml/kg per min group 1, 27.8 (±0.05) pre- and 43.4 (±0.07) post-transfusion in group 2 (p〈0.01). Conclusions CO measurements and serum lactate levels add little information to the decision-making process for blood transfusions, as neither CO nor serum lactate levels correlate with Hb levels in an otherwise asymptomatic population of preterm infants. In infants where the indication for blood transfusion is made based on traditionally accepted clinical criteria, serum lactate is an additional laboratory indicator of impaired oxygenation, as it correlates significantly with oxygen delivery. A significantly lower oxygen delivery in patients in whom blood transfusion is indicated and an increase in oxygen induced by transfusion demonstrate the value of these criteria in identifying preterm infants who benefit from transfusion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1238
    Keywords: Key words Anemia ; Preterm infants ; Serum lactate ; Cardiac output ; Oxygen saturation ; Blood transfusion ; Oxygen delivery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: Whether and when to transfuse in anemia of prematurity is highly controversial. Some authors suggest transfusions simply if the hemoglobin (Hb) level is below a defined normal range. Others propose the use of clinical or laboratory parameters in anemic patients to decide whether to transfuse or not. Hypothesis: A decreasing amount of circulating Hb should cause a compensatory increase in cardiac output (CO) and an increase in arterial serum lactate. Materials and methods: In 56 anemic preterm infants (not in respiratory or hemodynamic failure) we analyzed CO after the first week of life using a Doppler sonographic method. At the same time serum lactate levels, Hb levels and oxygen saturation were registered. Nineteen of these patients were given transfusion when they demonstrated clinical signs of anemia by tachycardia 〉180/min, tachypnea, retractions, apneas and centralization (group 2). The remaining 37 patients were not transfused (group 1). Serum lactate, CO, heart rate (HR), oxygen delivery, respiratory rate, capillary refill and Hb were analyzed in both groups and in group 2 before and 12–24 h after transfusion. Data between groups  1 and 2 and in group 2 before and after transfusion were compared. Results: In the 56 patients studied no linear correlation between Hb and CO or between Hb and serum lactate was found. Nor could any correlation be demonstrated between the other variables studied. Examining the subgroups separately, a negative linear correlation was demonstrated between serum lactate and oxygen delivery in group 2. No other significant correlations were detected. However, when the pre- and post-transfusion data were compared in group 2 (increase of Hb from 9.45 (SD 3.44) to 12.5 (SD 3.8) g/100 ml), the CO decreased from 281.3 (SD 162.6) to 224 (SD 95.7) ml/kg per min (p〈0.01) and serum lactate decreased significantly from 3.23 mmol/l (SD 2.07) before to 1.71 (SD 0.83) after transfusion. Oxygen delivery was 35.8 (±0.19) ml/kg per min group 1, 27.8 (±0.05) pre- and 43.4 (±0.07) post-transfusion in group 2 (p〈0.01). Conclusions: CO measurements and serum lactate levels add little information to the decision-making process for blood transfusions, as neither CO nor serum lactate levels correlate with Hb levels in an otherwise asymptomatic population of preterm infants. In infants where the indication for blood transfusion is made based on traditionally accepted clinical criteria, serum lactate is an additional laboratory indicator of impaired oxygenation, as it correlates significantly with oxygen delivery. A significantly lower oxygen delivery in patients in whom blood transfusion is indicated and an increase in oxygen induced by transfusion demonstrate the value of these criteria in identifying preterm infants who benefit from transfusion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 149 (1990), S. 789-791 
    ISSN: 1432-1076
    Keywords: Alpha 1-Antitrypsin ; Glycoproteins ; Resuscitation ; Shock ; Liver disease
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Microheterogeneity of the glycoprotein α1 has been investigated sequentially by high resolution isoelectric focusing in a child with the proteinase inhibitor MS phenotype after near-drowning A band-splitting with additional cathodal fractions exhibited migration from the most cathodic to the anodic positions of the glycoprotein isoforms in the course of postresuscitation disease. The pattern may reflect the time- and stage-dependent hypoxic and post-hypoxic effects on hepatocellular metabolic zonation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-1076
    Keywords: Neonatal septicaemia ; Elastase α1 proteinase inhibitor ; Granulocyte ; C-reactive protein
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In a prospective study elastase α1-proteinase inhibitor (Eα1PI), polymorphonuclear (PMN) count, the immature to total neutrophil count ratio (I/T ratio), and C-reactive protein (CRP) were analysed in 74 patients (76 cases) with neonatal septicaemia at the time of initial clinical symptoms. At that early stage of the disease, 94% of the patients had abnormal values for Eα1PI, 71% for I/T ratio, 61% for PMN count, and only 54% for CRP. PMN count was a poor indicator of septicaemia. Neutropenia, present in 26% of all patients, was related to normal Eα1PI in only 4 patients. The combined use of Eα1 and I/T ratio was the most sensitive indicator. In all patients irrespective of causative bacteria or disease onset at least one of these parameters was elevated. In early-onset septicaemia (n=31), normal CRP values occurred significantly more often (63%) than in late-onset sepsis (33%). Even in five of the seven fatal cases, initial CRP measurements were normal. The sensitivity of PMN count and I/T ratio did not differ significantly between early-and late-onset septicaemia. Laboratory changes observed in 18 newborns during the first 3 days of the septic episode show that the rate of pathological values for Eα1PI and I/T ratio was highest at the time of initial clinical symptoms and decreased on days 2 and 3. In contrast, CRP reached maximal values as late as day 2 (88% abnormal values), followed by a decrease on day 3. We conclude that the use of Eα1PI may improve the laboratory detection of neonatal septicaemia especially if used in combination with I/T ratio.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-1440
    Keywords: Meningitis ; Cerebrospinal fluid ; α 1-Proteinase inhibitor ; Elastase-α 1-proteinase inhibitor complex ; Elastase inhibition capacity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Mortality and long-term neurologic sequelae are still frequent complications of meningitis despite effective antibiotic treatment. This suggests that pathogen-independent inflammatory mechanisms may play an important role in the course of this illness. Neutrophil granulocytes form the primary immune defense in meningitis. Once activated, these cells release elastase into the cerebrospinal fluid (CSF). Elastase may induce tissue damage if local antiproteinase capacity is low as under normal conditions. To define the relevance of this mechanism we studied 22 patients with meningitis. Concentrations of elastase in complex with the main antiproteinaseα 1-proteinase inhibitor (elastase-α 1PI),α 1-proteinase inhibitor (α 1PI), and elastase inhibition capacity (EIC) were measured in CSF of 9 patients with bacterial meningitis (BM), aged 1 month-214 years; 13 patients with non-bacterial meningitis (NBM), aged 1 month–15 years; and 20 patients in whom meningitis was excluded after spinal tap (control group), aged 6 months–15 years. The concentration of elastase-α 1PI in the BM group (median 552 μg/l) was significantly higher than in either the NBM group (median 30 μg/l,p〈0.01) or the control group (median 30 μg/l,p〈0.01). Similarly, theα 1PI-concentration in the BM group was significantly higher (median 113 mg/l) than either the NBM group (median 13.7 mg/l,p〈0.025) or the control group (median 6.3 mg/l,p〈0.001). The concentration of elastase-α 1PI shows a significant correlation with the duration of the infectious symptoms before admission to the hospital (r=0.51,p〈0.02), but not with the number of neutrophil granulocytesr=0.23, p=0.21). Free elastolytic capacity in CSF could be demonstrated in 4 patients: 1 with BM, 2 with NBM, and 1 with pertussis pneumonia and enzephalitis. The measured insufficiency of the proteinase-antiproteinase system may indicate high-risk patients in need of additional anti-inflammatory therapy, e.g., with corticosteroids, during the initial phase of meningitis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Pediatric radiology 21 (1991), S. 521-522 
    ISSN: 1432-1998
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A preterm infant with severe hyaline membrane disease requiring extreme mechanical ventilation developed pulmonary air leaks with consecutive shock. The chest roentgenogram showed bilateral pulmonary interstitial emphysema and gas within the heart silhouette as well as in the hepatic veins, inferior v.cava, portal vein, and many abdominal vessels. The respiratory and circulatory failure by massive systemic gas embolism resulted in death.