Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 59 (1988), S. 2306-2307 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: An "optical carriage'' has been developed to improve plasma access for LIF diagnostics. Laser light inducing the fluorescence is transported through an optical fiber to the carriage. A telescope fixed on the carriage collects the plasma fluorescence light and sends it through a fiber bundle to an external PMT. The whole carriage is mounted on rails and can be scanned along and across the magnetic field.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 70 (1999), S. 2703-2707 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A silicon-based temperature stabilized axial Hall probe with an absolute accuracy of ±40 ppm in the full range between 0 and 6 T is presented. The absolute calibration of the probe is performed against a nuclear magnetic resonance (NMR) probe. The application of the probe to a magnetic field profile of a 5 T superconducting magnet system, with field gradients as high as 30 T/m, reaching an overall accuracy of better than ±100 ppm, is demonstrated. In addition to the high absolute accuracy, this Hall probe allows high spatial resolution measurements of inhomogeneous fields in configurations where present NMR probes are not usable. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 60 (1989), S. 3831-3832 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The comments made by Goeckner and Goree are correct, in general, but they are not relevant to our experiment. The measurements made with the optical carriage represent an average over the diagnosed volume, and the laser power is low enough to avoid the effect due to saturation broadening.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 74 (1993), S. 2229-2236 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The feasibility of Thomson scattering to determine the beam velocity in a gyrotron has been analyzed and preliminary experiments to implement such a system on our 100 GHz quasi-optical gyrotron are reported. Although the project had to be abandoned due to technical problems, the conclusions are that for the 90° scattering arrangement discussed it should be possible to determine at least one velocity component with an acceptable signal-to-noise ratio.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 79 (1996), S. 5854-5854 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We have deposited (100) and (111) oriented single-crystal Co1−xPtx films (x=0.65, 0.75, and 0.86) over a range of growth temperatures from −50 to 800 °C. The Curie temperature is increased by up to 200 °C over the value expected for the homogeneous, chemically disordered alloy in the as-deposited films (of both orientations) grown near 400 °C. Measurements of the onset of magnetic ordering below the Curie temperature indicate separation into Co-rich and Pt-rich regions. High resolution x-ray measurements show no shift in the lattice constant or broadening of the x-ray peaks, and no observable strain for x=0.75, suggesting that the separated regions are small and epitaxially coherent. We interpret this as evidence for a previously unobserved miscibility gap. The bulk phase diagram shows no phase separation, but magnetic energy tends to drive the system toward immiscibility as demonstrated by the calculations of several workers. We suggest that the observed miscibility gap is an equilibrium surface effect, trapped into the bulk film by low bulk mobility. Preliminary work by Rosengren and Kundrotas supports this idea. Large perpendicular magnetic anistropy is found in those films that exhibit an anomalously high Curie temperature (films grown near 400 °C). This anisotropy is likely related to the phase separation. After annealing at high temperatures, the Curie temperature approaches the homogeneous values and the anisotropy relaxes. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 73 (1993), S. 2089-2102 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The design of a diffration grating used as an output coupler for a Fabry–Pérot resonator is presented. We then consider the problem of determining the distortion and the cross-polarization of the incident Gaussian beam. Different types of gratings and planes with straight or curvilinear grooves and elliptical, have been designed and built. The output pattern from a resonator using such a grating has been measured experimentally. We found that the elliptical grating generates the least distortion and cross-polarization. This result is attributed to the geometry of the grooves and is in excellent agreement with numerical calculations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 67 (1990), S. 124-129 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A study of the application of high-order TM0m0 modes of a cylindrical cavity to the measurement of the density of a magnetized plasma column is presented. It is shown theoretically that judiciously chosen high-order modes have the potential advantages of both a wide operational range of densities, and a wide range for which a simple perturbation theory is valid. Furthermore, an experiment is described which shows that the TM060 mode can be excited with a sufficiently high Q value to allow accurate determination of the resonant frequencies, and hence plasma density. Favorable comparison between densities in the range 1010–1012 cm−3 measured by means of the resonant cavity technique and microwave interferometry is presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Physics of Plasmas 5 (1998), S. 2421-2430 
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Electron beam instabilities occurring in a gyrotron electron beam can induce an energy spread which might significantly deteriorate the gyrotron efficiency. Three types of instabilities are considered to explain the important discrepancy found between the theoretical and experimental efficiency in the case of quasi-optical gyrotrons (QOG): the electron cyclotron maser instability (ECMI), the electrostatic Bernstein instability (BI) and the Langmuir instability (LI). When the magnetic field gradient in drift tubes of QOG is low, the ECMI can develop in the drift tube at very low electron beam currents. Experimental measurements show that with a proper choice of absorbing structures in the beam tunnel, this instability can be suppressed. At high beam currents, the BI can induce a significant energy spread at the entrance of the interaction region. The induced energy spread scales approximately linearly with the electron beam density and for QOG one observes that the beam density is significantly higher than the beam density of an equivalent cylindrical cavity gyrotron. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The parallel velocity distribution function of the weakly relativistic electron beam of a quasi-optical gyrotron has been determined by measuring the Doppler-shifted Electron Cyclotron Emission (ECE) at an angle θ=15° with respect to the external magnetic dc-field. Due to the Doppler shift, the frequency of the spontaneous cyclotron emission at the fundamental (ν0=100 GHz) is upshifted to 140 GHz. A broadening of the spectrum up to 10 GHz [full width at half maximium (FWHM)] was measured. The measured mean frequency agrees well with the theoretical predictions, but the observed line-width, and hence the parallel velocity distribution function, is 2–3 times larger than expected. Considerations on ECE-measurements of the electron beam energy spread, performed at larger angles θ, are also discussed. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Physics of Plasmas 3 (1996), S. 3492-3500 
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The operation of a 92 GHz quasi-optical gyrotron having a resonator formed by a spherical mirror and a diffraction grating placed in −1 order Littrow mount is presented. A power of 150 kW with a Gaussian output pattern was measured. The Gaussian content in the output was 98% with less than 1% of depolarization. By optimizing the magnetic field at fixed frequency, a maximum efficiency of 15% was reached.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...