Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Acta crystallographica 52 (1996), S. 481-485 
    ISSN: 1399-0047
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Notes: d(ACGTACGT), C78H84N30O32P7.20H2O, Mr (DNA) = 2170, tetragonal, P43212 (No 96), a = 42.845 (1), b = 42.845(1), c = 24.804 (1) Å, V = 45532.5 (2) Å3, z = 8,λ(MoKα) = 0.71069 Å,µ(MoKα) = 0.10 mm−1, T = 295 K, R = 0.18 for 1994 unique reflections between 5.0 and 1.9 Å resolution. The self-complementary octanucleotide d(ACGTACGT)2 has been crystallized and its structure determined to a resolution of 1.9 Å. The asymmetric unit consists of a single strand of octamer with 20 water molecules. It is only the second example of an octanucleotide having terminal A·T base pairs whose structure has been determined by X-ray crystallography. The sequence adopts the modified A-type conformation found for all octanucleotide duplexes studied to date with the helix bent by approximately 15° and an average tilt angle of 0°. Unusually the data collection was carried out using a 3 kW molybdenum sealed-tube source. The conformational details are discussed in comparison with other closely related sequences.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Magnetic resonance materials in physics, biology and medicine 2 (1994), S. 327-334 
    ISSN: 1352-8661
    Keywords: magnetic resonance imaging ; angiography ; aneurysms ; embolization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics
    Notes: Abstract Several patients with intracranial aneurysms at our hospital have recently been treated with embolization of the aneurysm itself with detachable platinum coils. This has been done as part of a multicenter trial of GDC platinum coils. We report our experience in the follow-up of these patients with magnetic resonance (MR) after the embolization procedure. We present several illustrative cases and discuss the information that can be gained from the spin-echo images, the magnetic resonance angiography (MRA) source data, and the maximum intensity projection (MIP) reconstructions. We also examine the relative merits and limitations of MR in this role including thrombus formation, susceptibility artifact, and estimation of size and morphology of the aneurysms. We discuss the role of MRA in the planning of the embolization procedure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...