Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Cambridge : Cambridge University Press
    Journal of Germanic linguistics 4 (1992), S. 89-93 
    ISSN: 1470-5427
    Source: Cambridge Journals Digital Archives
    Topics: German, Dutch and Scandinavian Studies
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Polymer International 39 (1996), S. 295-302 
    ISSN: 0959-8103
    Keywords: heterogeneous nuclei ; crystalline-amorphous interphase ; PA 1010 ; radiation effects ; post-radiation effects ; fold surface of the lamellae ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Irradiated polyamide-1010 (PA 1010) and PA 1010 containing 0.5% (wt) heterogeneous nuclei were studied by ESR, WAXD, DSC and the determination of gel fractions. The fold surface of the lamellae plays an important role in the effects of radiation on crystalline PA1010. The results show that the direct radiation effects on both samples vary, while after being heated to 220°C, the final radiation effects are identical, regardless of the difference in the amount of the fold surface of the lamellae. The post-radiation effects result predominantly from the fold surface.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 67-72 
    ISSN: 0935-6304
    Keywords: Capillary electrochromatography ; monolithic column ; electroosmotic flow ; retention mechanism ; aromatic compound ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new kind of monolithic capillary electrochromatography column with poly(styrene-co-divinylbenzene-co-methacrylic acid) as the stationary phase has been developed. The stationary phase was found to be porous by scanning electron microscopy and the composition of the continuous bed was proved by IR spectroscopy to be the ternary polymer of styrene, divinylbenzene, and methacrylic acid. The effects of operating parameters, such as voltage, electrolyte, and organic modifier concentration in the mobile phase on electroosmotic flow were studied systematically. The retention mechanism of neutral solutes on such a column proved to be similar to that of reversed-phase high performance liquid chromatography. In addition, fast analyses of phenols, chlorobenzenes, anilines, isomeric compounds of phenylenediamine and alkylbenzenes within 4.5 min were achieved.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Polymer International 35 (1994), S. 335-359 
    ISSN: 0959-8103
    Keywords: polymide-1010 ; radiation effect ; wide angle X-ray diffraction ; crystal damage ; amorphotization ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Radiation effects on polyamide-1010 specimens having various states of aggregation were studied using wide angle X-ray diffraction, electron spin resonance, calorific and sol measurement techniques. Experimental results indicated that chain crosslinking and scission of the irradiated polyamide-1010 occurred mainly in the amorphous region and on the crystal surface. The radiation-induced crystal damage and amorphotization started from the crystal surface (or interface) and extended into the inner portion of the crystal with increasing radiation dose. It is believed that the interface between crystalline and amorphous regions was the main region wherein free radicals were trapped.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 666-670 
    ISSN: 0935-6304
    Keywords: Capillary electrochromatography ; mixed packing technique ; electroosmotic flow ; retention mechanism ; fast analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Mixed packing capillary electrochromatography (MP CEC) with the stationary phase comprising a physical mixture of strong cation exchange (SCX) phase and octadecysilyl (ODS) phase was developed. With the existence of a sulfonic acid group on the surface of SCX, not only could the electroosmotic flow (EOF) remain high at low pH, but also the hydrophilicity of the stationary phase was increased greatly, leading to broad adaptable ranges of both pH and organic modifier concentration in the mobile phase. At the same time, with the coexistence of C18 on the surface of ODS, both the retention and the resolution of samples were improved. Accordingly, MP CEC combined the advantages of both SCX and ODS columns. Effects of operation parameters on EOF and the capacity factors of solutes as well as the retention mechanism of such a column were studied systematically. In addition, MP CEC columns were used in the analysis of strong polar solutes as well as for the high speed separation of acidic, basic, and neutral compounds in a single run.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Macromolecular Chemistry and Physics 197 (1996), S. 553-562 
    ISSN: 1022-1352
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The blend polyamide 1010/N,N′-(diphenylmethane-4,4′-diyl)bismaleimide (PA1010/BMI) has been investigated by means of WAXD and SAXS. The results obtained with the help of the Ruland, variance and 1D EDCF analysis showed that the degree of crystallinity (Wc,x) crystallite size (Lhkl), long period (L) and thickness of average crystal lamellae (d) decrease with BMI content. Experimental and calculated density values (ρc) are in good agreement. Addition of BMI to PA1010 causes an increase in structural distortion. The results from SAXS analysis also supported that a crystalline amorphous interphase exists in the lamellae of semicrystalline polymers, so that a three-phase model instead of the traditional two-phase model should be used.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...