Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0935-6304
    Keywords: Fast gas chromatography ; peak band broadening ; packed capillary columns ; narrow-bore columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0935-6304
    Keywords: Polymer analysis ; High temperature gas chromatography ; PTV injectors ; Thermal desorption ; Pyrolysis GC ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Thermal treatment hyphenated with gas chromatography is a versatile and powerful tool in the study of polymer characterization. An inexpensive system where thermal treatment at different temperatures occurs inside a Programmable Temperature Vaporization injector (PTV) is described. The samples investigated, commercial plastics, are complex mixtures that contain several polymers and additives. These plastics as well as their pure constituents are subjected to multi-step thermal treatment. The individual chromatograms of the various constituents of the polymeric sample are correlated with those of the final material in order to identify additives (thermal desorption) and degradation products (pyrolysis). Results obtained with the new method indicate the interesting potentials of the technique for the characterization of polymer compositions. Reproducibility of absolute and relative peak areas has been considered and found to be acceptable. The absence of a heated transfer line and switching valves, which are always present in conventional set-ups, eliminates the risk of losses of high molecular weight components. Further advantages of the technique proposed are simplicity, versatility, and its inexpensive nature.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 119-122 
    ISSN: 0935-6304
    Keywords: Fast gas chromatography ; multi-capillary column ; band broadening ; simulation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 21 (1998), S. 583-586 
    ISSN: 0935-6304
    Keywords: Fast gas chromatography ; narrow-bore columns ; flash-2D-GC ; dedicated fast GC instrumentation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Savings in analysis time in capillary GC have always been an important issue for chromatographers since the introduction of capillary columns by Golay in 1958. In laboratories where gas chromatographic techniques are routinely applied as an analytical technique, every reduction of analysis time, without significant loss of resolution, can be translated into a higher sample throughput and hence reduce the laboratory operating costs. In this contribution, three different approaches for obtaining fast GC separations are investigated. First, a narrow-bore column is used under conventional GC operating conditions. Secondly, the same narrow-bore column is used under typical fast GC conditions. Here, a high oven temperature programming rate is used. The third approach uses a recent new development in GC instrumentation: Flash-2D-GC. Here the column is placed inside a metal tube, which is resistively heated. With this system, a temperature programming rate of 100°/s is possible. The results obtained with each of these three approaches are compared with results obtained on a column with conventional dimensions. This comparison takes retention times as well as plate numbers and resolution into consideration.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...