Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Artikel: DFG Deutsche Nationallizenzen  (2)
  • 25.70.-z  (1)
  • Immunoscintigraphy  (1)
Datenquelle
  • Artikel: DFG Deutsche Nationallizenzen  (2)
Materialart
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    The European physical journal 335 (1990), S. 73-76 
    ISSN: 1434-601X
    Schlagwort(e): 25.70.-z ; 25.90.+ k
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract Negative pion production cross-sections are measured at 38, 65 and 93 MeV per nucleon in O + Al reaction. Rough estimations of the total cross sections are given and compared to previous neutral pion data. Double differential cross sections at 93 and 65 MeV/u show enhancement for pions with velocity close to the beam. At variance no effect is observed at 38 MeV, where π− and π0 distributions are identical. Fewπ + detected at 38 MeV support this result. This indicates that at the lowest incident energy nearly the whole projectile participates in the production reaction.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    European journal of nuclear medicine 13 (1987), S. 391-396 
    ISSN: 1619-7089
    Schlagwort(e): Immunoscintigraphy ; Image subtraction
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Recently proposed image comparison software is applied to immunoscintigraphy. The software performs geometric and gray level registration of two images and generates an image of the statistically significant differences. It permits the comparison of scintigraphic images recorded at different times. It is used to subtract 113mIn and 111In-phytate colloid liver scans and early (blood pool) images from 131I or 111In-monoclonal Ab images and to compare Ab images recorded at different times. Using the procedures made possible by this software, only images recorded using the same radionuclide or using radionuclides of about the same energy are compared. Anti CEA, 19-9 and OC 125 F(ab)2 fragments labeled with 131I or 111In are used in 32 patients with 47 demonstrated recurrences or metastases of colorectal or ovarian cancers. The overall sensitivities of the unprocessed and processed images are 25/47 and 41/47 respectively. The improvement in sensitivity is particularly high in the liver when In labelled Ab are used. This technique improves the contrast of the images, but the interpretation must take into account the components of the non target activity (kidney, bone marrow, colon...) which are not removed by the image subtraction method.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...