    Description / Table of Contents: Zusammenfassung Der Bericht befaßt sich mit dem Wärmeübertragungsverhalten in einem vertikalen, zweidimensionalen offenen Thermosyphon mit längs der vertikalen Wand verteilten, beheizten Hohlräumen als Wärmequellen. Zur Messung des Wärmeüberganges wird Luft, zur Strömungsbeobachtung Transformatorenöl verwendet. Besonderes Interesse gilt den Einflüssen der Hohlraumtiefe und der lichten Weite für den Hauptstrom auf das Verhalten des Wärmeüberganges bei freier Konvektion. Die Umgebungstemperatur wird auf 10°C gehalten, während die Hohlraumbodentemperatur und die lichte Weite für den Hauptstrom variiert werden mit Rayleigh-Zahlen zwischen 1.2×101 und 3.8×106. Es wird festgestellt, daß der Einfluß der lichten Weite auf das Wärmeübertragungsverhalten unerwartet groß ist. Die experimentellen Ergebnisse werden in Diagrammen der Nusselt-Zahl über der Rayleigh-Zahl dargestellt. Ein Zusammenhang für die Nusselt-Zahl als Funktion von der Rayleigh-Zahl und dem Verhältnis von lichte Weite zu Länge wird gegeben.
    Notes: Abstract This paper is concerned with the heat-transfer characteristics in a vertical two-dimensional open thermosyphon whose heat sources are the heated cavities dotted along the vertical wall. Air is utilized for the measurement of heat transfer, while transformer oil for the observation of the flow patterns. Attention is particularly focussed on the effects of the depth of cavity and the clearance for main fluid-flow on the behavior of free convective heat transfer in the present open thermosyphon. Environmental temperature is maintained at 10°C, while temperature of the bottom-surface of cavity and the clearance of main fluid-flow are parametrically varied, as Rayleigh number ranging from 1.2×101 to 3.8×106. It is found that the effect of the clearance on the heat-transfer characteristics in the two-dimensional open thermosyphon is unexpectedly large. Experimental results are finally given as plots of Nusselt number versus Rayleigh number. An experimental correlation is given for the Nusselt number as a function of the Rayleigh number and the clearance/length ratio of the open thermosyphon.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...