ISSN:
0935-6304
Keywords:
GC/MS
;
2,3,7,8-TCDD
;
Stack gases
;
Seveso waste incineration
;
Fast cycle trace analysis
;
Adsorptive charcoal filter
;
Chemistry
;
Analytical Chemistry and Spectroscopy
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Chemistry and Pharmacology
Notes:
The fast trace analysis method used to monitor 2,3,7,8-TCDD in stack gas during the incineration of the waste from Seveso is described. The sampling of volatile organic compounds from flue gases, distributed between all three aggregation states, is based on a micromethod developed for the trace analysis of water using a specially dimensioned adsorptive charcoal filter (1.5 mg charcoal). In conjunction with subsequent GC/MS measurements the rapid “fast cycle trace analysis” ensured specific 2,3,7,8-TCDD detection down to 100 pg per m3 flue gas in cycle times of about 1-2 hours.
Additional Material:
7 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/jhrc.1240110609