Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • 1997  (2)
Material
Years
  • 1995-1999  (2)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Hyperfine interactions 108 (1997), S. 207-218 
    ISSN: 1572-9540
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract High-accuracy mass measurements have recently been performed on radioactive isotopes produced by proton-induced spallation at the on-line isotope separator ISOLDE at CERN and by heavy-ion projectile fragmentation at the fragment separator FRS at GSI. At ISOLDE, singly charged ions were injected into the Penning trap mass spectrometer ISOLTRAP and their masses determined by observing their cyclotron frequencies in the homogeneous magnetic field of the ion trap. At GSI, bare, hydrogen, or helium-like ions were injected into the experimental storage ring ESR, electron-cooled to the same velocity, and their masses determined by observing their revolution frequencies in the ESR. With ISOLTRAP and ESR, resolving power in the range of 4 × 105〈 = m/Δ m(FWHM)〈 = 107 and an accuracy up to \delta m/m~ 10-7 were achieved for radioactive isotopes. Mass measurements of highly charged ions of stable isotopes were performed at Stockholm by use of SMILETRAP. In this case, a resolving power of about 108 and an accuracy close to 10-9 were obtained.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1572-9540
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract First direct mass measurements on rare earth isotopes around 146Gd have been performed with the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. More than 40 isotopes of the elements Pr, Nd, Pm, Sm, Eu, Dy and Ho have been measured with an accuracy of typically 1 × 10-7. In the case of 141Sm isomeric and ground state (ΔE = 175 keV) were resolved. Since isobaric contaminations are present in the ISOLDE beam, these measurements on rare earth isotopes became only possible after the installation of a new cooler trap which acts an isobar separator.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...