Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • 1920-1924
  • 1997  (2)
Material
Years
  • 1995-1999  (2)
  • 1920-1924
Year
  • 1
    ISSN: 1573-4838
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract The biocompatibility and osseous integration of a new composite material made of polyurethane and a calcium silicophosphate ceramic was investigated in a loaded implant model in sheep and compared to that of commercially pure titanium. Six months after implantation, interfacial shear strength was higher between the titanium and bone than between the composite and bone. After 2 years, however, the shear strength was significantly higher in the composite group. Histologically, both implants were surrounded by bone and fibrous tissue and there were no signs of inflammation. Direct contact of bone on the composite surface increased significantly with time, whereas there was no time-dependent increase of bone contact on titanium. It can be concluded that the biocompatibility and osseous integration of the composite was very good in the loaded implant model used. It is therefore suggested that the new composite is a promising biomaterial for orthopaedic implants.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-4838
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract The aim of this study was to evaluate the healing capacity of proximal anterior cruciate ligament (ACL) ruptures following primary repair with and without a bioresorbable augmentation. The ACL was transected at the femoral origin in the right knee joint of 24 sheep. The ACL was repaired in eight sheep (group B) without, and in eight sheep (group C) with a bioresorbable augmentation. Eight sheep without repair served as a control (group A). No immobilization was performed in any group. The sheep were sacrificed 13 weeks post-operatively. Macroscopically, all repaired ACLs were healed. The augmentation device was broken in all cases, but not completely degraded. In group A, none of the transected ACLs had healed. The anterior drawer under a load of 50 N was significantly lower in group C than in group A (p〈0.01). No significant difference was seen between groups B and A. The distribution and extent of chondromalacia (CM) in the operated knees depended on the type of operative treatment (p〈0.01). Groups A and B showed significantly more CM in the operated knee than in the non-operated knee (each p〈0.05). Proximal ACL ruptures can heal in sheep after both non-augmented and augmented ACL repair with free-functional rehabilitation. However, augmented repair leads to significantly better stability of the knee joint compared to transected controls and better limits the development of degenerative changes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...