Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1995-1999  (7)
  • 1850-1859
  • 1998  (7)
  • 1
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 84 (1998), S. 1305-1309 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: We report the results of a two-step two-dimensional (2D) diffusion study by scanning capacitance microscopy (SCM) and 2D SUPREM IV process simulation. A quantitative 2D dopant profile of a gate-like structure is measured with the SCM on a cross-sectioned polished silicon wafer. The gate-like structures consist of heavily implanted n+ regions separated by a lighter doped n-type region underneath 0.56 μm gates. The SCM is operated in the constant-change-in-capacitance mode. The 2D SCM data are converted to dopant density through a physical model of the SCM/silicon interaction. This profile has been directly compared with 2D SUPREM IV process simulation and used to calibrate the simulation parameters. The sample is then further subjected to an additional diffusion in a furnace for 80 min at 1000 °C. The SCM measurement is repeated on the diffused sample. This final 2D dopant profile is compared with a SUPREM IV process simulation tuned to fit the earlier profile with no change in the parameters except the temperature and time for the additional diffusion. Our results indicate that there is still a significant disagreement between the two profiles in the lateral direction. SUPREM IV simulation considerably underestimates the diffusion under the gate region. © 1998 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Oxford : Blackwell Science Ltd
    Anaesthesia 53 (1998), S. 0 
    ISSN: 1365-2044
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Caudal epidural injection is a simple procedure that carries a low risk of complications. The whoosh test (injection of air into the caudal epidural space with simultaneous auscultation over the thoracolumbar spine) has been recommended as an aid to correct needle placement. A 1-year prospective study, using fluoroscopic imaging to identify needle position, was conducted to compare the sensitivity and specificity of the whoosh test with that of clinical impression alone in assessing correct needle placement in the caudal space. Of 131 patients studied, correct needle placement was achieved in 121 on the first attempt (92%). Clinical impression alone had a sensitivity of 94% and a specificity of 20%. The whoosh test had a sensitivity of 80% and a specificity of 60%. The whoosh test is superior to clinical judgment in detecting incorrect caudal needle placement.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 1365-3091
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Geologie und Paläontologie
    Notizen: In the Muskeg Trough of northcentral Alberta the Gilwood Member contains widespread carbonate deposits that formed within terrigenous mudstone and sandstone hosts. Stratigraphic, depositional and petrographic relationships indicate that these carbonates represent calcretes and dolocretes. Calcretes, observed best with cathodoluminescence, display microcrystalline alpha fabrics, circumgranular cracks, root networks, displacive growth fabrics, elongate channel voids and rare coloform growths with flower spar. Similarly, dolocretes have microcrystalline alpha fabrics, brecciation, gradational contacts with host mudstones, extensive layered nodular horizons and are associated with anhydrite and pyrite. δ13C values range between −7‰ to +1‰ and –6‰ to +3‰ for calcretes and dolocretes, respectively. Oxygen isotopes are more variable and differ with host lithologies. δ18O of calcretes ranges between −11‰ to −8‰ for sandstones and −8‰ to −3‰ for mudstones, whereas δ18O of dolocretes ranges between −3‰ to 1‰ for marine mudstones and −6‰ to −2‰ for pedogenic mudstones. Regional mapping indicates that calcretes thicken towards the deepest parts of the Muskeg Trough. Widespread dolocretes extend beyond the eastern and western limits of Muskeg Trough and are useful marker intervals for regional correlations. Dolocretes of restricted lateral extent are found within gleyed palaeosol mudstones next to calcretized channel sandstones.Calcrete isotopic values are interpreted as indicative of carbonate precipitation from waters with meteoric water input. However, the higher δ18O values in dolocretes are indicative of a contribution from an isotopically heavier source such as seawater. Stratigraphically, calcretes are most common along the western and northern edges of Muskeg Trough; thus, calcrete accumulation was further controlled by meteoric water in-flow from the highland to the west and sluggish groundwater flow in Muskeg Trough. In contrast, regionally widespread dolocrete horizons appear to have formed from mixing of fresh waters derived from the highland to the west and seawaters introduced from the east. Regionally restricted dolocretes which are found next to channel sandstones formed from groundwater out-flow from the permeable channel sandstones which resulted in calcretization in channel proximal mudstones and dolomitization in channel distal mudstones.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    Abdominal imaging 23 (1998), S. 117-121 
    ISSN: 1432-0509
    Schlagwort(e): Key words: Small intestine, radiography—Intestine, diagnosis—Crohn disease—Endoscopy.
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract. Background: This study aimed to document the radiological features and distribution of small bowel Crohn disease (CD) in adults by using a barium follow-through (BaFT) technique and to determine whether disease would be missed or its distribution underestimated if only colonoscopy with ileoscopy were performed. Methods: The BaFT examinations of 121 adults with proven CD were reviewed retrospectively with respect to the stage and distribution of disease. Colonoscopy with attempted ileoscopy was performed in 37 of these subjects, and the results were compared with radiological findings. Results: A normal villous pattern was visualized in 89 studies (74%). BaFT showed small bowel CD in 71 (59%) of 121 patients studied. The terminal ileum (TI) was the most common site of disease, affecting 62 (87%) of patients with small bowel CD. Forty-six patients (65%) had more proximal small bowel disease, including nine (13%) with a normal TI. BaFT showed early mucosal changes of CD in 52 subjects (73%), which was the sole manifestation in 15 (21%). Ileoscopy was possible in the majority of patients colonoscoped but was not achieved in 14 (38%), nine of whom had CD on BaFT. Of the 23 patients in whom ileoscopy was performed, findings agreed with BaFT assessment of the TI in 22. Conclusion: BaFT adequately demonstrates the stage and extent of small bowel CD. The majority of patients with small bowel CD have disease proximal to the TI, which cannot be diagnosed by ileoscopy.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Springer
    Annals of oncology 9 (1998), S. 601-605 
    ISSN: 1569-8041
    Schlagwort(e): narrative reviews ; publication bias ; meta-analysis
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Springer
    Annals of oncology 9 (1998), S. 375-375 
    ISSN: 1569-8041
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Springer
    Journal of thermal analysis and calorimetry 54 (1998), S. 901-911 
    ISSN: 1572-8943
    Schlagwort(e): cobalt ; isomorphous substitution ; manganese ; tetraalkylammonium cations
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Abstract Pure silica zeolite ZSM-5 has been synthesised in a slightly acidic aqueous fluoride medium which produces the protonated form of the zeolite ZSM-5 [1]. Tetrahalometallate [2] species of cobalt and manganese have been synthesised and increasing mole fractions incorporated into the zeolite synthesis gel. The products have been analysed and characterised using simultaneous thermogravimetric-derivative thermogravimetric analysis (TG-DTG). The thermal decomposition, under nitrogen of the associated tetraethylammonium (TEA+) and tetrapropylammonium (TPA+) cations occluded within the zeolite channels is indicative and characteristic of the incorporation of the heteroatoms into the zeolitic framework. Analysis by X-ray diffraction (XRD), scanning electron microscopy (SEM), X-ray fluorescence (XRF), and Fourier transform infrared spectroscopy (FTIR) has confirmed the reliability of thermogravimetric (TG) and derived thermogravimetric analysis (DTG) as a diagnostic tool.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...