Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • 1998  (2)
Material
Years
  • 1995-1999  (2)
Year
  • 1
    ISSN: 1432-041X
    Keywords: Key words Bombyxin ; Insulin ; Bombyx mori ; Multigene family ; Brain neurosecretory cell
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract  Bombyxin G1 gene, a novel insulin-related peptide gene of the silkmoth Bombyx mori, has been identified. The G1 gene encodes a precursor peptide which shows 41–56% and 28% sequence identities with preprobombyxins previously characterized and human preproinsulin, respectively. The G1 gene forms a pair with bombyxin C2 gene with opposite transcriptional orientation in a bombyxin gene cluster. The bombyxin G1 mRNA in Bombyx brain was shown to locate in four pairs of medial neurosecretory cells.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 3181-3185 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A millimeter-wave interferometer having a capability of concomitant electron temperature measurement, based on the electron cyclotron absorption (ECA) technique, has been developed for divertor diagnostics in JT-60U. Three lines of sight, which pass through the X point horizontally, the inboard divertor and the outboard divertor, are chosen. Two transmitter/receiver units with frequencies of 217 and 183 GHz are employed in order to eliminate the spurious vibration effect using a two color scheme. The two independent units are also arranged to enable two sight line measurements without the vibration compensation. Furthermore, these units allow us to apply the simultaneous ECA diagnostic. Due to the complexity of the transmission line inside the tokamak, the insertion loss is as large as 65 dB. However, the interferometer system can be operated with the signal-to-noise (S/N) ratio of about 20 dB due to the low equivalent input noise of −90 dB m. The measurements performed for several types of the JT-60U discharges indicate the feasibility of the system and the rapid reduction of the electron density near the X point at the high confinement mode transition is first demonstrated. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...