Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (5)
  • 1980-1984
  • 2001  (5)
Material
Years
  • 2000-2004  (5)
  • 1980-1984
Year
  • 1
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: X-ray powers on the order of 10 TW over an area of 4.5 mm2 are produced in the axial direction from the compression of a low-density foam target centered within a z-pinch on the Z generator.1 The x rays from this source are used for high-energy–density physics experiments, including the heating of hohlraums for inertial confinements fusion studies.2 In this article, detailed characteristics of this radiation source measured using an upgraded axial-radiation-diagnostic suite3 together with other on- and off-axis diagnostics are summarized and discussed in terms of Eulerian and Lagrangian radiation–magnetohydrodynamic code simulations. The source, characterized here, employs a nested array of 10-mm-long tungsten wires, at radii of 20 and 10 mm, having a total masses of 2 and 1 mg, and wire numbers of 240 and 120, respectively. The target is a 14 mg/cc CH2 foam cylinder of 5 mm diameter. The codes take into account the development of the Rayleigh–Taylor instability in the r–z plane, and provide integrated calculations of the implosion together with the x-ray generation. The radiation exiting the imploding target through the 4.5 mm2 aperture is measured primarily by the axial diagnostic suite that now includes diagnostics at an angle of ∼30° to the z axis. The near on-axis diagnostics include: (1) a seven-element filtered silicon-diode array,4 (2) a five-element filtered x-ray diffraction (XRD) array,5 (3) a six-element filtered PCD array,6 (4) a three-element bolometer,7 (5) time-resolved and time-integrating crystal spectrometers, and (6) two fast-framing x-ray pinhole cameras having 11 frames each. The filtered silicon diodes, XRDs, and PCDs are sensitive to 1–200, 140–2300, and 1000–4000 eV x rays, respectively. They (1) establish the magnitude of the prepluse generated during the run in of the imploding wire arrays, (2) measure the Planckian nature of the dominant thermal, and (3) nonthermal component of the emission. The bolometers and XRDs mounted on the near-normal and 30° LOS (line-of-sight) measure the total power and check the Lambertian nature of the emission. Additionally, a suite of filtered fast-framing x-ray pinhole cameras and silicon-diode arrays behind a transmission grating, mounted on LOSs nearly normal to the z axis, quantify the plasma plume exiting the aperture. The hard bremsstrahlung generated is estimated with both on- and off-axis shielded scintillator photomultiplier diagnostics. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Aquaculture research 32 (2001), S. 0 
    ISSN: 1365-2109
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: A feed budget model, which enables farmers to adapt a general model to local conditions, was tested on rainbow trout, Oncorhynchus mykiss (Walbaum). The model has two major components; component 1 is used to calculate the energy required for one unit of biomass gain (g or kg) and component 2 estimates the daily growth increment (g or kg). Both components can be adjusted in relation to prevailing environmental conditions and, together, they express the daily energetic requirement of the specific species or strain. Fish fed using the model as a guide had a high rate of growth and good feed conversion. The model accurately predicted growth over the experiment, and is presented as a means of calculating the daily feed budget in fish farming. Growth of fish fed using self-feeders is presented for comparison with the results obtained using the model.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    European journal of soil science 52 (2001), S. 0 
    ISSN: 1365-2389
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences , Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: The test for the degree of phosphorus (P) saturation (DPS) of soils is used in northwest Europe to estimate the potential of P loss from soil to water. It expresses the historic sorption of P by soil as a percentage of the soil's P sorption capacity (PSC), which is taken to be α (Alox + Feox), where Alox and Feox are the amounts of aluminium and iron extracted by a single extraction of oxalate. All quantities are measured as mmol kg soil−1, and a value of 0.5 is commonly used for the scaling factor α in this equation. Historic or previously sorbed P is taken to be the quantity of P extracted by oxalate (Pox) so that DPS = Pox/PSC.The relation between PSC and Alox, Feox and Pox was determined for 37 soil samples from Northern Ireland with relatively large clay and organic matter contents. Sorption of P, measured over 252 days, was strongly correlated with the amounts of Alox and Feox extracted, but there was also a negative correlation with Pox. When PSC was calculated as the sum of the measured sorption after 252 days and Pox, the multiple regression of PSC on Alox and Feox gave the equation PSC = 36.6 + 0.61 Alox+ 0.31 Feox with a coefficient of determination (R2) of 0.92. The regression intercept of 36.6 was significantly greater than zero. The 95% confidence limits for the regression coefficients of Alox and Feox did not overlap, indicating a significantly larger regression coefficient of P sorption on Alox than on Feox. When loss on ignition was employed as an additional variable in the multiple regression of PSC on Alox and Feox, it was positively correlated with PSC. Although the regression coefficient for loss on ignition was statistically significant (P 〈 0.001), the impact of this variable was small as its inclusion in the multiple regression increased R2 by only 0.028. Values of P sorption measured over 252 days were on average 2.75 (range 2.0–3.8) times greater than an overnight index of P sorption. Measures of DPS were less well correlated with water-soluble P than either the Olsen or Morgan tests for P in soil.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] We have placed 7,600 cytogenetically defined landmarks on the draft sequence of the human genome to help with the characterization of genes altered by gross chromosomal aberrations that cause human disease. The landmarks are large-insert clones mapped to chromosome bands by fluorescence in situ ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The finished sequence of human chromosome 20 comprises 59,187,298 base pairs (bp) and represents 99.4% of the euchromatic DNA. A single contig of 26 megabases (Mb) spans the entire short arm, and five contigs separated by gaps totalling 320 kb span the long arm of this metacentric ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...