Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 2005-2009  (1)
  • 2000-2004
  • 1975-1979
  • 2005  (1)
Materialart
Erscheinungszeitraum
  • 2005-2009  (1)
  • 2000-2004
  • 1975-1979
Jahr
  • 1
    Digitale Medien
    Digitale Medien
    Oxford, UK and Malden, USA : Blackwell Science Ltd
    BJOG 112 (2005), S. 0 
    ISSN: 1471-0528
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Objective  To evaluate the effectiveness of a new handheld vacuum delivery device.Design  Randomised controlled trial.Setting  Southmead Hospital, Bristol, UK.Population  One hundred and ninety-four women requiring delivery with vacuum extraction.Methods  Women were recruited into the study while still in early labour. If during delivery, vacuum extraction was indicated they were then randomly allocated to either a new handheld vacuum device, the Kiwi Omnicup, or to a ‘standard’ vacuum cup selected by the obstetrician. The ‘standard group’ consisted of the silastic (66/98, 67%) or the metal cups (32/98, 33%). Study data were recorded at completion of the delivery and at 24–48 hours. An additional brief symptom questionnaire was completed by the mother at 10 days postnatally. Statistical analyses were done on an ‘intention-to-treat’ basis.Main outcome measures  The primary outcome was the successful completion of delivery with the allocated instrument. Secondary outcomes were substantial fetal scalp trauma and substantial maternal trauma.Results  The Omnicup was associated with a significantly higher failure rate than the standard cup [34%vs 21%, odds ratio (OR) = 1.9 (1.01–3.6)]. This difference persisted after adjusting for confounding factors [adjusted OR = 2.25 (1.01–5.0)] and resulted in significantly more forceps deliveries in the Kiwi Omnicup group [22%vs 10%, unadjusted OR = 2.5 (1.1–5.5)]. The caesarean section rates were similar in both groups [9.4%vs 8.2%, OR = 1.2 (0.4–3.2)]. Rates of substantial scalp trauma and maternal trauma were similar in both groups. However, there were more cases of jaundice in the standard cup group [2.3%vs 12.0%, unadjusted OR = 0.18 (0.04–0.82) and adjusted OR = 0.10 (0.01–0.88)].Conclusions  The Omnicup is not as successful at achieving a vaginal delivery as the combination of the currently used vacuum cups.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...