Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 69 (1991), S. 6023-6023 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: The present study focuses on magnetic fields of the brain activities during sleep, in particular on K-complexes, vertex waves, and sleep spindles in human subjects. We analyzed these waveforms based on both topographic EEG (electroencephalographic) maps and magnetic fields measurements, called MEGs (magnetoencephalograms). The components of magnetic fields perpendicular to the surface of the head were measured using a dc SQUID magnetometer with a second derivative gradiometer. In our computer simulation, the head is assumed to be a homogeneous spherical volume conductor, with electric sources of brain activity modeled as current dipoles. Comparison of computer simulations with the measured data, particularly the MEG, suggests that the source of K-complexes can be modeled by two current dipoles. A source for the vertex wave is modeled by a single current dipole which orients along the body axis out of the head. By again measuring the simultaneous MEG and EEG signals, it is possible to uniquely determine the orientation of this dipole, particularly when it is tilted slightly off-axis. In sleep stage 2, fast waves of magnetic fields consistently appeared, but EEG spindles appeared intermittently. The results suggest that there exist sources which are undetectable by electrical measurement but are detectable by magnetic-field measurement. Such source can be described by a pair of opposing dipoles of which directions are oppositely oriented.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 69 (1991), S. 6023-6023 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: We made a functional map of the human motor cortex related to the hand and foot areas by stimulating the human brain with a focused magnetic pulse. We observed that each functional area in the cortex has an optimum direction for which stimulating currents can produce neural excitation. The present report focuses on the mechanism which is responsible for producing this anisotropic response to brain stimulation. We first obtained a functional map of the brain related to the left ADM (abductor digiti minimi muscles). When the stimulating currents were aligned in the direction from the left to the right hemisphere, clear EMG (electromyographic) responses were obtained only from the left ADM to magnetic stimulation of both hemisphere. When the stimulating currents were aligned in the direction from the right to the left hemisphere, clear EMG signals were obtained only from the right ADM to magnetic stimulation of both hemisphere. The functional maps of the brain were sensitive to changes in the direction of the stimulating currents. To explain the phenomena obtained in the experiments, we developed a model of neural excitation elicited by magnetic stimulation. When eddy currents which are induced by pulsed magnetic fields flow in the direction from soma to the distal part of neural fiber, depolarized area in the distal part are excited, and the membrane excitation propagates along the nerve fiber. In contrast, when the induced currents flow in the direction from the distal part to soma, hyperpolarized parts block or inhibit neural excitation even if the depolarized parts near the soma can be excited. The model explains our observation that the orientation of the induced current vectors reflect both the functional and anatomical organization of the neural fibers in the brain.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 69 (1991), S. 4925-4927 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: We have observed that gas flow can be blocked or disturbed by magnetic fields. To explain this phenomenon, we developed a model called a "magnetic curtain'' based on the paramagnetic properties of the oxygen molecule. In this paper, we applied this phenomenon to the control of heat transport in heat pipes. We used a heat pipe 20 mm in diameter and 500 mm in length packed with oxygen as a working fluid. We positioned this device vertically in an airgap 70-mm wide between the poles of electromagnet with 240 mm in diameter, in the direction perpendicular to the axis of the magnetic poles. The top side of the heat pipe was chilled with liquid nitrogen (77 K), and the lower side of the heat pipe was exposed to the room temperature (290 K). The efficiency of heat transport was measured by monitoring the change of the temperature at seven points inside and outside of the heat pipe in response to the step change of the top temperature from 290 to 77 K. When the middle part of the heat pipe was exposed to magnetic fields of 1.0 T with the gradient of 5–50 T/m, the heat transport was apparently blocked.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 69 (1991), S. 6019-6021 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: A noninvasive method of magnetic stimulation of the spinal roots was designed. The basic idea is to concentrate induced eddy currents in a target by a pair of opposing pulsed magnetic fields. A figure-eight coil was positioned outside the median of the back so that time varying magnetic fields pass through the body in opposite directions around the target. Magnetic stimulation of the spinal roots of human and a rabbit was carried out. It was found that each spine level can be stimulated selectively, producing electromyographic waves related to both the H-reflex and M-wave. The results indicate that the M-wave can be produced by currents flowing either in the rostral or caudal direction, whereas the H-reflex is only generated by currents flowing in the caudal direction. The H-reflex elicited by magnetic stimulation of nerves in the vicinity of the spine becomes a new tool in diagnosis of neuromuscular system diseases.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 67 (1990), S. 5477-5477 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: We have observed a phenomenon that candle flames are pressed down by magnetic fields. We have also observed that flows of gases such as carbon dioxide and oxygen are blocked by magnetic fields. A model, called a "magnetic curtain,'' has been introduced to explain these phenomena. The magnetic curtain is a wall of air which is produced by magnetic fields. We have demonstrated an experiment to show that candle flames are quenched by the magnetic curtain. The present study focuses on the mechanism of the phenomena involving quenching of flames using magnetic fields. An electromagnet with a pair of columnar magnetic poles in which inner sidepieces were hollowed out was used first. Magnetic fields of 1.5 T at the brim gave a gradient of 50–300 T/m in the direction perpendicular to the pole axis. Alcohol was burned in the hollowed space between magnetic poles. Gases around flames in the hollowed space were sampled into gas sensors through an inhalation nozzle. Oxygen, carbon dioxide, and carbon monoxide were simultaneously measured during the combustion of methanol and ethanol. During magnetic field exposures, oxygen concentration decreased, whereas concentrations of carbon dioxide and carbon monoxide increased. However, when flames were quenced in a few seconds, oxygen concentration in the hallowed space was not changed, and very little of carbon dioxide and carbon monoxide were produced. The interception of a small amount of oxygen near the surface of the flames may quench flames. Emission spectra of flames of methanol and ethanol were measured before, during, and after magnetic field exposures, using both uniform and gradient magnetic fields. Intensity of the OH radical was not changed by magnetic fields up to 1.6 T, whereas the emission intensity was increased when the product of magnetic fields and the gradient increased.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 87 (2000), S. 6205-6207 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: The purpose of our study was to identify the current source produced by acute ischemia and infarction. We measured magnetocardiograms (MCG) and electrocardiograms (ECG) of five male rats using a high-resolution dc superconducting quantum interference device gradiometer in a magnetically shielded room after performing coronary artery occlusion. The spatial resolution of the detecting magnetic field of our system is higher than the typical system, thus permitting the measurement of magnetic fields in small animals. Distribution of the magnetic fields B(t) and distribution of |rot B(t)|, which corresponded to the distribution of the current source, were imaged by 12-channel MCGs. As a result, the distribution of current source changes in the affected area of the myocardium during the ST segment, and amplitude of the peak significantly increased after occlusion. Our system can be used to help clarify the mechanism of the ST shift related to severe heart disease. © 2000 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 75 (1994), S. 7168-7170 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: This study focuses on the influences of spreading multiple dipoles in the human head upon surface magnetic fields. A source model of the magnetoencephalogram (MEG) activity is proposed. This source model is expressed by spreading multiple dipoles which have time-varying dipole moments. Using this source model, spatio-temporal patterns of MEGs are simulated. Effects of spreading dipoles on spatio-temporal magnetic fields are investigated. The computer simulations show that the wave forms and amplitude of magnetic fields are affected significantly by the spread of the source and the conduction velocity of traveling dipoles. The latency of the peak magnetic field generated by spreading multiple dipoles varies with the measurements points on the surface of the head.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 75 (1994), S. 7177-7179 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: This study focuses on the properties of diamagnetic fluid in static magnetic fields up to 8 T with the gradient of 50 T/m. We used a horizontal type of superconducting magnet with a bore 100 mm in diameter and 700 mm long. We observed the phenomenon that the surface of the water was pushed back by magnetic fields of higher gradients. Two "frozen'' cascades were formed at z=±50–80 mm; the surface of the water near the center of the magnet was parted, and the bottom of the water chamber appeared. The water level at both ends of the chamber was lifted up. In order to investigate the hydrodynamics of diamagnetic fluid in magnetic fields, we made a fluidic circuit with plastic tubing which passed through the superconducting magnet's bore. When magnetic fields in the center of the bore were changed from 0 to 8 T, the flow velocity of distilled water decreased, and the flow was stopped at 8 T. A stress analysis of diamagnetic fluid in magnetic fields was carried out to explain the mechanism of these phenomena. The hydrodynamics of diamagnetic fluid in ∼400 T2/m is able to compare with that of ferromagnetic fluid in weak magnetic fields. Studying the role of diamagnetic fluid in gradient magnetic fields is important in understanding the mechanism of biological effects of magnetic fields.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 75 (1994), S. 7162-7164 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: In this study, we investigated the possible effects of magnetic fields on the fibrinolytic process. Fibrin dissolution was observed and the fibrinolytic activities were evaluated. First, fibrinolytic processes in magnetic fields were investigated by the fibrin plate method. We gathered solutions from the dissolved fibrin, and measured mean levels of fibrin degradation products (FDPs) in solutions. Mean levels of FDPs exposed to 8 T magnetic fields were higher than those not exposed to fields. Second, we carried out an experiment to understand how fibrin oriented in a magnetic field dissolves. FDPs in solutions of dissolved fibrins in fibrin plates were assayed. The result was that fibrin gels formed in a magnetic field at 8 T were more soluble than those not formed in a magnetic field. A model based on the diamagnetic properties of macromolecules was explained, and changes of protein concentrations in a solution in gradient magnetic fields were predicted.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 75 (1994), S. 7174-7176 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: The influence of static magnetic fields on the behavior of oxygen dissolved in an aqueous solution was studied in order to clarify the interaction mechanism of dynamic movements of dissolved oxygen with magnetic fields and to broaden the basic understanding of biological effects of magnetic fields. A horizontal type of superconducting magnet with a bore 100 mm in diameter was used. A cylindrical chamber filled with distilled water was exposed to magnetic fields up to 8 T and a gradient of 50 T/m. The spatial distribution of oxygen concentration dissolved in water was measured by a dissolved oxygen meter. A clear redistribution of oxygen concentration was observed, and the dissolved oxygen concentration increased more than 10% around the center of the magnet.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...