Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (2)
  • 1965-1969  (6)
  • 1
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A highly uniform thermal x-radiation field for indirect-drive inertial confinement fusion implosions may be obtained by irradiating a four-hole, tetrahedral geometry, spherical hohlraum with all 60 Omega laser beams. Implosion studies and calculations [J. M. Wallace et al., Phys. Rev. Lett. 82, 3807 (1999)] indicate a drive uniformity comparable to that expected for the National Ignition Facility [J. A. Painser et al., Laser Focus World 30, 75 (1994)]. With 60 beams distributed over the cavity wall, tetrahedral hohlraums have a natural insensitivity to power balance and pointing errors. Standard, smooth Nova capsules imploded with this drive indicate that moderate convergence-ratio implosions, Cr∼18, have measured-neutron yield to calculated-clean-one-dimensional-neutronyield ratios similar to those previously investigated using the comparatively poor drive uniformity of Nova cylindrical hohlraums. This may indicate that a nonsymmetry-related neutron yield degradation mechanism, e.g., hydrodynamic mixing of cold, dense ablator material with the hot-spot region or some combination of nonsymmetry effects, is dominating in this Cr regime. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 72 (2001), S. 657-662 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The Z-Beamlet laser backlighter system at Sandia National Laboratories, which will be operational in 2001, will create a point or area source of high (or moderate) energy x rays behind a Z-accelerator [R. B. Spielman et al., Phys. Plasmas 5, 2105 (1998)] -driven target. In the former case with 〉2 kJ in up to four pulses of 〈2 ns total duration in a 20 ns interval, and 〉80% of the 2ω energy in a ∼50-μm-diam focal spot, the resulting 〉4×1016 W/cm2 irradiances will generate ≥8.950, 8.999 keV (zinc He-α, etc.) x rays. This high-energy source, as either a single point or four separate spots, will be used directly for four-frame point-projection x-ray imaging, and will attain spatial resolutions and signal-to-noise levels significantly better than presently possible on Z using existing methods. In combination with a ∼1 cm field of view, the technique will be well suited to the large, relatively opaque objects characteristic of Z experiments. This addition is anticipated to have a major impact upon the basic physics of z-pinch implosions, and therefore, possibly the ultimate x-ray powers and hohlraum (vacuum or dynamic) radiation temperatures that may be attainable. Furthermore, in combination with a slightly defocused point source and a medium-energy grazing-incidence microscope, Z-Beamlet may allow various inertial confinement fusion and high-energy-density physics experiments to be studied at even higher spatial resolution and signal-to-noise levels. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    facet.materialart.
    Unknown
    London : Periodicals Archive Online (PAO)
    Archives. 7:35 (1966:Apr.) 180 
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    facet.materialart.
    Unknown
    Harlow, etc. : Periodicals Archive Online (PAO)
    English Historical Review. 84:331 (1969:Apr.) 358 
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    facet.materialart.
    Unknown
    Harlow, etc. : Periodicals Archive Online (PAO)
    English Historical Review. 82:325 (1967:Oct.) 726 
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    facet.materialart.
    Unknown
    London : Periodicals Archive Online (PAO)
    Journal of theological studies. n.s.:20 (1969) 697 
    ISSN: 0022-5185
    Topics: Theology and Religious Studies
    Notes: AUTHORS AND BOOKS REVIEWED OR NOTICED
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    The @Anatomical Record 165 (1969), S. 543-557 
    ISSN: 0003-276X
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Light and electron microscopic radioautographs of the tissues of young rats which were sacrificed at various times after a single 3H-ribose injection revealed a wide distribution of the label.Nuclear reactions were seen over hepatocytes and other cell types. After removal of RNA by treatment with RNAse, most nuclear reactions were absent; they were, therefore, attributed to the incorporation of label into newly-synthesized RNA. In about 2% of the nuclei, however, labeling persisted after RNAse, but was absent after DNAse treatment, indicating uptake into newly-synthesized DNA. Hence, ribose may be taken up into nucleic acidsundergoing synthesis.In cells of liver and cartilage as well as in some muscle fibers, moderate reaction appeared over glycogen areas. Removal of the label by salivary amylase confirmed its uptake into glycogen.In mucous and other secretory cells, amylase resistant radioautographic reactions appeared over the Golgi region and later over secretion products. Presumably the label was incorporated into the glycoproteinmoieties of these secretions.Many, if not all, cells in the body appear to be able to utilize free exogenous ribose. It is presumed that ribose is first phosphorylated and then either incorporated into the RNA and DNA being synthesized in the nucleus or converted into the glucose or fructose derivatives used for glycogen and glycoprotein synthesis in the cytoplasm. That these pathways may play a significant physiological role is suggested by the recent finding of free ribose in the blood.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 13 (1969), S. 2371-2381 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The viscosity-average molecular weight, Mv, of a polymer is given operationally through its limiting viscosity number [η] and the Mark-Houwink equation [η] = KMvα, where K and α are empirical constants. If [η] is measured under different conditions, α and Mv will vary for the same sample. Mvα is the α-order moment about the origin of the differential weight distribution of the polymer. Practically, the results of a series of Mv measurements on the same polymer are equivalent to a cluster of fractional moments of the weight distribution, with orders between 0.55 and 0.80. It is shown that the first moment of this distribution, Mw, may be estimated reliably by a straightline plot of Mv against α-extrapolated to α equals 1. This simple expedient is effective although there are probably no molecular weight distributions in which the relation is strictly linear and there are no mathematical distributions for which the αth root of the αth moment is a linear function of α for all α. The deviation from linearity is small enough, however, that the real curve can be represented by a straight line over a short range of α. Thus, Mw can be measured accurately, but Mn, Mz, or the breadth of the distribution is not accessible by this method. Experimental and literature examples show that the precision of Mw estimated by this method compares well with that of primary methods for measuring this molecular weight average. If a linear relationship is observed with reliable α values, this appears to be a sufficient condition for estimation of a valid Mw.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...