ISSN:
1089-7623
Source:
AIP Digital Archive
Topics:
Physics
,
Electrical Engineering, Measurement and Control Technology
Notes:
In the Saha Institute of Nuclear Physics Tokamak (SINP-TOKAMAK), simultaneous measurement of signals from some diagnostics, like, electrostatic probes, etc., is not possible because pickup noises due to the formation of ground and other loops affect them quite severely. To avoid these loops and also to isolate some diagnostics from the ground, we developed a new type of optical isolator using a very low cost optical isolator chip (MC2TE made by Motorola) in a novel configuration. We continuously kept the light emitting diode on and used a feedback arrangement at the receiving side of the photoemitted signal for achieving good isolation for very low signals with reasonably high frequency response and good linearity. The method is highly cost effective in low budget tokamak experiments. © 2000 American Institute of Physics.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1063/1.1287042