Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (4)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 71 (2000), S. 1122-1124 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The energy distributions of C− and C2− beams extracted from a plasma-sputter-type negative ion source with the concave graphite target were measured by a retarding field energy analyzer having 1.5% resolving power. The reduction in energy spread of the energy distribution functions was observed by adding Cs into the discharge. The observed energy spreads of C− beam for 650 V target bias were 15 eV without Cs and 13 eV with Cs, respectively. The shift toward the lower energy due to Cs supply was also observed. The observed negative energy shift was constant at about 3.7 eV for the C beam, the value corresponded to the work function reduction from a pure graphite to Cs covered graphite surface. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 71 (2000), S. 719-721 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Spatial distributions of the current density of the ion beams extracted from an electron-stimulated-desorption-type powdery sample ion source have been measured. The vertical profile showed an asymmetry which can be attributable to the localized ion emission at the powder surface. The deflection of the beam in the horizontal direction caused by the magnetic field for guiding the electron's motion to hit the powder surface was also confirmed. Despite the presence of this inhomogeneity which may degrade the beam quality, the positive and negative oxygen ion beams produced from BaO powder with the beam energy as low as 2 kV were focused to about 2 mm diameter. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 958-960 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The velocity distribution function of the gas effusing from a 5.5-cm-diam, 5-cm-long small ion source was measured by the mass separated time-of-flight method. The measured distribution function could be fitted to a Maxwellian distribution before the commencement of a discharge, when the deuterium pressure in the ion source was below 0.6 Pa. The effect of discharge upon the distribution function of neutral deuterium below this operating pressure was investigated by changing the arc power. The deuterium gas temperature determined by fitting the measured distribution function to a Maxwellian showed a maximum gas temperature of 800 K at discharge power density of 6 W/cm3. Effects of discharge upon argon and helium gas temperature were also measured, which showed a monotonic increase against the discharge power. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1439-0264
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The immunohistolocalization of carbonic anhydrase isozymes (CA-I, II, III) in canine salivary glands was studied using antiserum against CA-I, II, III. In parotid glands, immunostaining intensely localized cytosolic CA-II antiserum throughout the cytoplasm of acinar secretory cells and ductal epithelial cells, especially in the striated duct region. CA-III reactivity in the glands was only seen selectively at the intercalated ductal cells. In contrast, no immunoreaction localized CA-I in the gland. In the submandibular and sublingual glands, CA-I, II, and III were all observed in the ductal segments of the glands, whereas serous demilune appeared devoid of all three cytosolic CA isozymes. In contrast, in zygomatic glands (i.e. dorsal buccal glands) all CA isozymes were observed in both serous demilune and ductal segments. In all of the salivary glands examined, no mucous acinar cells were found to be reactive for any CA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...