    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Introduction: The implantable cardioverter defibrillator (ICD) is commonly used to treat patients with documented sustained ventricular tachycardia (VT) or ventricular fibrillation (VF). Arrhythmia recurrence rates in these patients are high, but which patients will receive a therapy and the forms of arrhythmia recurrence (VT or VF) are poorly understood. Methods and Results: The therapy delivered by the ICD was examined in 449 patients randomized to ICD therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial. Events triggering ICD shocks or antitachycardia pacing (ATP) were reviewed for arrhythmia diagnosis, clinical symptoms, activity at the onset of the arrhythmia, and appropriateness and results of therapy. Both shock and ATP therapies were frequent by 2 years, with 68% of patients receiving some therapy or having an arrhythmic death. An appropriate shock was delivered in 53% of patients, and ATP was delivered in 68% of patients who had ATP activated. The first arrhythmia treated in follow-up was diagnosed as VT (63%), VF (13%), supraventricular tachycardia (18%), unknown arrhythmia (3%), or due to ICD malfunction or inappropriate sensing (3%). Acceleration of an arrhythmia by the ICD occurred in 8% of patients who received any therapy. No physical activity consistently preceded arrhythmias, nor did any single clinical factor predict the symptoms of the arrhythmia. Conclusion: Delivery of ICD therapy in AVID patients was common, primarily due to VT. Inappropriate ICD therapy occurred frequently. Use of ICD therapy as a surrogate endpoint for death in clinical trials should be avoided. (J Cardiovasc Electrophysiol, Vol. 14, pp. 940-948, September 2003)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Unexplained Syncope in AVID. Introduction: A prospective registry and substudy were conducted in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Study to clarify the prognosis and recurrent event rate, risk factors, and impact of implantable cardioverter defibrillator (ICD) therapy in patients with unexplained syncope, structural heart disease, and inducible ventricular tachyarrhythmias. Methods and Results: Included in the AVID registry were patients from all participating sites who had “out of hospital syncope with structural heart disease and EP-inducible VT/VF with symptoms.” In addition, 13 collaborating sites provided more in-depth clinical and electrophysiologic data as part of a formal prospective substudy. Patients in the substudy were followed by local investigators for recurrent arrhythmic events and mortality. Registry patients were tracked for fatal outcomes by the National Death Index. A total of 429 patients with syncope were entered in the AVID registry, of whom 80 participated in the substudy. Of the substudy patients, 21 patients (26%) had inducible polymorphic ventricular tachycardia/ventricular fibrillation (VT/VF), 11 patients (14%) had sustained monomorphic VT 〈 200 beats/min, and 48 patients (60%) had sustained monomorphic VT ≥200 beats/min. The ICD was used as sole therapy in 75% of the syncope substudy patients (and with antiarrhythmic drug in an additional 9%) and in 59% of the syncope registry patients. Survival rates at 1 and 3 years were 93% and 74% for the substudy patients and 90% and 74% for the registry patients, respectively. Survival of the syncope substudy patients (predominantly treated by ICD) was similar to the VT patients treated by ICD and superior to the VT patients treated by an antiarrhythmic drug (P = 0.05) in the randomized main trial. Mortality events in the substudy were marginally predicted by ejection fraction (P = 0.06) but not by electrophysiologic study-induced arrhythmia. The significant predictor of increased mortality in the registry was age (P = 0.003) and of reduced mortality was treatment with ICD (P = 0.006). Conclusion: The results of these analyses support the role of the ICD as primary antiarrhythmic therapy in patients with unexplained syncope, structural heart disease, and inducible VT/VF at electrophysiologic study.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Left Atrial Isthmus. Introduction: We observed a change in the atrial activation sequence during radiofrequency (RF) energy application in patients undergoing left accessory pathway (AP) ablation. This occurred without damage to the AP and in the absence of a second AP or alternative arrhythmia mechanism. We hypothesized that block in a left atrial “isthmus” of tissue between the mitral annulus and a left inferior pulmonary vein was responsible for these findings. Methods and Results: Electrophysiologic studies of 159 patients who underwent RF ablation of a left free-wall AP from 1995 to 1999 were reviewed. All studies with intra-atrial conduction block resulting from RF energy delivery were identified. Fluoroscopic catheter positions were reviewed. Intra-atrial conduction block was observed following RF delivery in 11 cases (6.9%). This was evidenced by a sudden change in retrograde left atrial activation sequence despite persistent and unaffected pathway conduction. In six patients, reversal of eccentric atrial excitation during orthodromic reciprocating tachycardia falsely suggested the presence of a second (septal) AP. A multipolar coronary sinus catheter in two patients directly demonstrated conduction block along the mitral annulus during tachycardia. Conclusion: An isthmus of conductive tissue is present in the low lateral left atrium of some individuals. Awareness of this structure may avoid misinterpretation of the electrogram during left AP ablation and may be useful in future therapies of atypical atrial flutter and fibrillation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 15 (2004), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , U.S.A . : Blackwell Publishing Inc
    Pacing and clinical electrophysiology 26 (2003), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Because of a significant survival benefit in the defibrillator arm of the Antiarrhythmics versus Implantable Defibrillator (AVID) Trial, patients in the antiarrhythmic drug (AAD) arm were advised to undergo ICD implantation. Despite this recommendation, ICD implantation in AAD patients was variable, with a large number of patients not undergoing ICD implantation. Patients were grouped by those who had been on AAD 〈 1 year (n = 111) and those on AAD 〉 1 year (n = 223). Multiple clinical and socioeconomic factors were evaluated to identify those who might be associated with a decision to implant an ICD. The primary reason for patients not undergoing ICD implantation was collected, as well as reasons for a delayed implantation, occurring later than 3 months from study termination. Of 111 patients on AAD for less than 1 year, 53 received an ICD within 3 months compared to 40/223 patients on AAD for more than 1 year (P 〈 0.001). Patient refusal was the most common reason to not implant an ICD in patients on drug 〈 1 year; physician recommendation against implantation was the most common in patients on drug 〉 1 year. Multivariate analysis showed ICD recipients on AAD 〈 1 year were more likely to be working and have a history of myocardial infarction (MI), while those on AAD 〉 1 year were more likely to be working, have a history of MI and ventricular fibrillation, and less likely to have experienced syncope, as compared to those who did not get an ICD. Having private insurance may have played a role in younger patients receiving an ICD. (PACE 2003; 26:2235–2240)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: General modalities of analyses that have, been used for ICD studies are reviewed. Published “typical” examples are briefly described. The historical cohort method is exemplified with previously unpublished data from the Seattle Cardiac Arrest Survivor database. The AVID Study database is used to compare the results obtained from nonrandomized methodologies with randomized methodologies. Particular issues related to the use of the ICD for example, mode of death, inability to blind, selection practice, and treatment decision times make this a natural pedagogic platform.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Climatic change 45 (2000), S. 223-251 
    ISSN: 1573-1480
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract Adaptation to climate variability and change is important both for impact assessment (to estimate adaptations which are likely to occur) and for policy development (to advise on or prescribe adaptations). This paper proposes an "anatomy of adaptation" to systematically specify and differentiate adaptations, based upon three questions: (i) adapt to what? (ii) who or what adapts? and (iii) how does adaptation occur? Climatic stimuli include changes in long-term mean conditions and variability about means, both current and future, and including extremes. Adaptation depends fundamentally on the characteristics of the system of interest, including its sensitivities and vulnerabilities. The nature of adaptation processes and forms can be distinguished by numerous attributes including timing, purposefulness, and effect. The paper notes the contribution of conceptual and numerical models and empirical studies to the understanding of adaptation, and outlines approaches to the normative evaluation of adaptation measures and strategies.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Journal of contemporary psychotherapy 30 (2000), S. 195-207 
    ISSN: 1573-3564
    Keywords: Virtual reality therapy ; fear of flying ; anxiety disorders
    Source: Springer Online Journal Archives 1860-2000
    Topics: Psychology
    Notes: Abstract A new and innovative approach to treating fear of flying has been developed using Virtual Reality Exposure Therapy. This article discusses the development of Virtual Reality Exposure Therapy and reviews a case study of a fear of flying patient seen in our practice. Early results are very promising and may indicate that Virtual Reality Exposure Therapy may also lead to creative interventions with other anxiety disorders.